Log:
Assessments - 4, GPA: 3.5 ( )

Instruções de Operação Oregon Scientific, Modelo BAR800

Fabricante : Oregon Scientific
Arquivo Tamanho: 2.78 mb
Arquivo Nome : BAR800A.pdf
Língua de Ensino: svitenesfrdenlpt
Ir para baixar



Facilidade de uso


Next 12 -24 hour weather forecast 3. Radio controlled clock reception icon 4. Outdoor Temperature / Humidity 5. Indoor Temperature / Humidity 6. Clock with seconds / weekday and Calendar BACK VIEW 1 2 34 5 6 1. Battery compartment 2. / increase / decrease value of the setting; enable / disable clock reception 3. Wall mount hole 4. RESET: Reset unit to default settings 5. MODE: Change display; set clock 6. °C / °F: Select temperature unit REMOTE SENSOR FRONT VIEW BACK VIEW 1 2 3 4 5 6 1. RESET: Reset unit to default settings 2. EU / UK Switch (RTGN318D sensor only) 3. Channel Switch 4. Double sided adhesive tape 5. Wall mount hole 6. Battery compartment GETTING STARTED MAIN UNIT INSTALLATION 1. Remove the battery compartment cover. 2. Insert the batteries, matching the polarities. 3. Press RESET after each battery change. NOTE Batteries should not be exposed to excessive heat such as sunshine or fire. LOCATION MEANING Clock / alarm area Main unit batteries low Outdoor sensor area Sensor batteries low REMOTE SENSOR INSTALLATION 1. Slide open the battery door. 2. Slide channel switch to channel 1. 3. Select EU/UK. (RTGN318D only) 4. Insert the battery, matching the polarities (+ / -). 5. Press RESET after each battery change. 6. Close the battery door. The sensor reception icon shows the status: ICONS MEANING Main unit is searching for sensor(s) A sensor channel has been found and logged on. No sensor found NOTE If no sensor is found, press and hold and on the main unit. NOTE After every sensor initialisation, the main unit may take up to 30 minutes to receive the time from the sensor. 7. Secure the sensor in the desired location using the wall mount hole or double sided adhesive tape. For best results: • Place the sensor within 30 m (100 ft) of the main unit. • Place the sensor out of direct sunlight and moisture. • Position the sensor so that it faces the main unit, minimizing obstructions such as doors, walls and furniture. • Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects. • Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. CLOCK CLOCK RECEPTION This product is designed to synchronize its clock automatically with a clock signal received from provided remote sensor. To enable / disable signal reception: Press and hold to enable or to disable signal reception. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. Clock signal reception indicator: STRONG SIGNAL WEAK / NO SIGNAL NOTE Clock reception is dependent on the successful transmission of data from remote sensor. If is displayed, press RESET on sensor and press and on the main unit and ensure sensor has been successfully logged. MANUALLY SET CLOCK To set the clock manually, disable the clock signal reception first. 1. Press and hold MODE. 2. Press / to change the settings. 3. Press MODE to confirm. The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (month – day / day – month), month, day and language. Time zone offset sets the clock +/- 23 hours from the received clock signal time. NOTE If you enter + 1 in the time offset setting, this will give you your local time plus one hour. If you are in the US (BAR800A) set the clock to: 0 for Pacific time +1 for Mountain time +2 for Central time +3 for Eastern time NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S). To select clock display mode: Press MODE to toggle between clock with seconds, clock with weekday and calendar. WEATHER FORECAST This product forecasts the next 12-24 hours of weather within a 30-50 km (19-31 mile) radius. Sunny Partially Cloudy Cloudy Rainy Snowy TEMPERATURE To toggle temperature unit: Press °C / °F. RESET Press RESET to return to the default settings. SPECIFICATIONS MAIN UNIT TYPE DESCRIPTION L x W x H 142 x 10 x 125mm (5.59 x 0.39 x 4.92 in) Weight 150 g (5.29 oz) without battery Power 2 x CR2032 batteries REMOTE RF CLOCK THERMO HYGRO SENSOR TYPE DESCRIPTION L x W x H 64 x 25 x 98 mm (2.52 x 0.98 x 3.86 in) Weight 80 g (2.8 oz) without battery Temperature range -30°C to 70°C (-22°F to 158°F) Resolution 0.1°C (0.2°F) Weather Forecast Accuracy 75% Signal frequency 433 MHz Transmission range 30 m (100 ft) unobstructed No. of channels 5 Power 1 x UM-3 (AA) 1.5 V batteries PRECAUTIONS • Do not subject the unit to excessive force, shock, dust, temperature or humidity. • Do not cover the ventilation holes with any items such as newspapers, curtains etc. • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. • Do not clean the unit with abrasive or corrosive materials. • Do not tamper with the unit’s internal...

Este manual também é adequado para os modelos :
equipamento de barco - BAR800A (2.78 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias