Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação ACR Electronics, Modelo Nauticast Y1-03-0211

Fabricante : ACR Electronics
Arquivo Tamanho: 3.62 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Enter RefPtExt (location of the external GPS antenna) in the same way. Ship length and beam have to be entered in dm. Conversion 1m is 10dm. NOTE: The field ATIS Code will be shown as Call Sign in “High Seas” - Mode. The field Length(ship) and Beam(Ship) are only the values of the ship and calculated in dm (1m / 10). For stand alone ship enter same dimensions, Length(ship) and Beam(Ship) again. Save the new settings by pressing [Save]. Press [Back] return to the Main Menu Screen without saving any changes. N 1o19' E 0o12' |1>0.01|2>1.30|3>1.80nm ************ Ship Settings ************* Atis Code :max. 7ASCII +------+ ShipName :NAUTICAST(TM) INLAND AIS | | Length(Conv):400m | A Beam(Conv) :32m | | RefPtExt :A380 B20 C8 D24m | x--| RefPtInt :A380 B20 C8 D24m | | B Length(ship):600dm | | | Beam(ship) :220dm +-C-+D-+ ---------------------------------------- | Save | | | Back Dynamic Keys: Input of Ship Settings [M5] [Save] Confirm Data Input [M8] [Back] Return to Main Menu After the Ship Settings have been input and saved, this screen appears. [Exit] takes the user back to the Main Menu. GPS Antenna Mounting It is important to input the exact mounting position of the GPS Antenna on the vessel as this influences the accuracy of the displayed target in an ECDIS. (RefPntExt:) = The position of any external positioning device (GPS Antenna) used as primary position source. (RefPntInt:) = The position of the GPS Antenna (fallback device in case primary source is disabled). NOTE: When receiving position data from large vessels, it should be considered that the position refers to the antenna mounting point upon the vessel. To ensure accurate navigation, the antenna reference points (see Other Vessels Details) should be taken into consideration when determining the vessels position. Also, the electronic chart display in use should be programmed to consider the antenna reference points. Traffic images are represented in true distances only when all displayed targets, including own vessel, are working with AIS position information, which considers antenna reference points. N 1o30' E 0o24' |1>0.10|2>1.30|3>1.80nm ---------------------------------------- ++++++++++++++++++++++++++++++++++++++++ Data saved. ++++++++++++++++++++++++++++++++++++++++ ---------------------------------------- | | | | <-Exit 3.5.4 Transponder Configuration (User Password Protected) The Configuration Menu allows the user to alter the hardware-based parameters. User Password Configuration is also undertaken here. Accessing the Configuration Settings: The Configuration Menu is User Password protected. NOTE: Please see Appendix 7.3 for password information. N 1o22' E 0o15' |1> N/A|2>0.00|3>0.10nm |---------------------------------- | 5. Transponder Configuration -----| | | +- 1. Change User Password View | +- 2. Region Settings | +- 3. Alarm Settings -----| +- 4. Interrogation Settings | +- 5. Sensor Settings Msg. | +- 6 Inland AIS quality Info | -----| | Displ| ---------------------------------------- NUM|Select->| | |<-Back Dynamic Keys: Transponder Configuration [M5] [Select] Select desired Submenu [M8] [Back] Return to Main Menu Accessing the Configuration Menu (Please see Appendix 7.3 for password information) The letters of the Password appear as * when being input on the screen. N 1o18' E 0o12' |1>0.10|2>1.30|3>1.80nm ---------------------------------------- ++++++++++++++++++++++++++++++++++++++++ User password protected! Please enter user password: **** ++++++++++++++++++++++++++++++++++++++++ ---------------------------------------- | Enter | | | Exit Dynamic Keys: Input of Default User Password to Access Configuration [M5] [Enter] Confirm Default User Password Input [M8] [Exit] Return to Vessel Listing Incorrect User Password Input If the incorrect User Password is input, the screen below appears. N 1 o34' E 0 o27' |1>0.10|2>1.30| * 1A1L ---------------------------------------- ++++++++++++++++++++++++++++++++++++++++ Access denied! ++++++++++++++++++++++++++++++++++++++++ ---------------------------------------- | | | | <-Exit Dynamic Keys: User Password Input (Access Denied) [M5] [Exit] Return to Vessel Listing a) Change User Password (for initial NAUTICAST Operation) It is strongly recommended to change the default User Password upon initial NAUTICAST operation. The new User Password can be between 6 - 8 characters in length, and is not case sensitive. N 1 o19' E 0 o12' |1>0.10|2>1.30|3>1.80nm |---------------------------------- | 5. Configuration -----| | | +- 1. Change User Password View | +- 2. Region Settings | +- 3. Alarm Settings -----| +- 4. Interrogation Settings | +- 5. Sensor Settings Msg. | | -----| | Displ| ---------------------------------------- NUM|Select->| | |<-Back N 1 o33' E 0 o27' |1>0.10|2>1.30| * 1A1L ********* Change User Password ********* Enter new password: ***** Repeat new password: ***** {Length: 4..8 characters} ---------------------------------------- | Enter | | | Back Dynamic Keys: Initial User Password Se...

Este manual também é adequado para os modelos :
equipamento de barco - Nauticast 2662 (3.62 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias