Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Electrolux, Modelo 269550

Fabricante : Electrolux
Arquivo Tamanho: 895.32 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If necessary remove the glue using an a non-corrosive solvent, rinsing it off and drying carefully. • Dispose of packaging material in compliance with the regulations in force in the country where the product is to be used. 15 USA 5938 036 01 3.2 WARNINGS REGARDING THE FLUING SYSTEM Before installation check, on the basis of the contents of the reference standard, to ensure that the volume aspirated by the fumes exhausting system is greater than the volume of combusted gas produced by the appliance (see point 1.1). If the solution of combusted gas discharge under an extractor hood is chosen, observe the distance (shown in the figure) between the top of the discharge pipe and the lowest point of the hood filters. This distance is defined on the basis of discharge pipe diameter "D". In the case of discharge direction to the outside or into a central flue (Fig. "1c"), the discharge ducts must NOT present an overall length in excess of 762"(3 metres), must NOT have any reductions in diameter, and must be subjected to periodic inspection and, when necessary, cleaning. Warning: Since combusted gas (see figure) can reach very high temperatures, check the heat resistant properties of extension ducts if fitted and the filters in the extractor hood to ensure the materials are compatible with the temperature conditions. In addition, periodically check the condition of the filters which, if excessively fouled with fat and dirt, will reduce the efficiency of the suction system and may catch fire. 3.3 INSTALLATION OF ACCESSORIES Accessories can be easily installed by following the figures below together with the relative key. The screw holes for fixing accessories "A" and "F" are 0.14"(3.5 mm) in diameter and they must be drilled in-situ on the oven cover in correspondence with the punch marks. CONSTRUCTION TYPE A3 1a LEGENDA: A: Cam / draught damper accessory (to be ordered from manufacturer) B: Boiler combusted gas discharge C: Oven chamber convector combusted gas discharge E: Adapter ring for commercial ducts (to be ordered from manufacturer) DIRECT UNDUCTED DISCHARGE UNDER EXTRACTOR HOOD CONSTRUCTION TYPE B13 1b DISCHARGE WITH SHROUD UNDER EXTRACTOR HOOD CONSTRUCTION TYPE B13 1c DISCHARGE TO THE OUTSIDE OR CENTRAL FLUE WITH SHROUD F: Conical connections for single outlet (supplied) (always install) G: Fixing screws (supplied); *: Commercial extension pipes (not supplied) SILICONE : Apply silicone sealant between contact surfaces 16 USA 5938 036 4. ELECTRICAL CONNECTION • A fused disconnect switch or main circuit breaker (customer furnished) MUST be installed in the electric supply line for the appliance. It is recommended that this switch/circuit breaker have lockout/tagout capability. Before making any electrical connections to this appliance, check that the power supply is adequate for the voltage, amperage, and phase requirements on the rating plate. • A safety cutout switch of suitable capacity with a contact breaking distance of at least 3 mm must be fitted upstream of the appliance. The cutout switch must be installed near the appliance in the permanent electrical system of the premises. • The appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. The grounding conductor must therefore be connected to the terminal marked Gon the connection terminal board. The appliance must also be connected to an earth grounding system. This connection is made using the stop screw marked E located on the outside of the appliance near the power cable inlet. The grounding wire must have a minimum cross-section of 8 AWG (10 mm2). RATING PLATE 4.1 INSTALLING THE POWER SUPPLY CABLE To access the power supply cable connection terminal board, proceed as follows: Model 6 - 10 - 20 GN • Remove the left side panel. • Connect the power supply cable to the terminal board according to the instructions given in the wiring diagram and fasten the power supply cable by means of strain-relief fitting (not furnished with the oven). Failure to comply with safety rules and regulations relieves the manufacturer of all liability. The manufacturer requires when stacking units each appliance have its own branch circuit protection. An oven unit stacked with an blast chiller unit should have a separate protection for the upper and lower units. 5. WATER MAINS CONNECTION (Refer to the installation diagrams at the beginning of this booklet). This equipment is to be installed to comply with the applicable Federal, State, Local plumbing codes, or the Basic Plumbing Code of the Building Officials and Code Administrators International Inc. (BOCA) and Food Service Sanitation Manual of the Food and Drug Administration (FDA). When connecting the appliance to the water system with flexible tubes they must be new and not used. The appliance is fitted with two separate water inlets ("B" and "N"). The water lin...

Este manual também é adequado para os modelos :
Fornos de microondas - Air-O-Steam 267554 (895.32 kb)
Fornos de microondas - 269554 (895.32 kb)
Fornos de microondas - Air-O-Steam 267550 (895.32 kb)
Fornos de microondas - Air-O-Steam 267552 (895.32 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias