Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação DeVillbiss Air Power Company, Modelo Excell A20118

Fabricante : DeVillbiss Air Power Company
Arquivo Tamanho: 5.53 mb
Arquivo Nome : 10f61161-fa84-4e39-8c35-6f6f6b6dcdc0.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


NOTE: Cone side faces out. Filter Screen 5. Connect water source to pump inlet. NOTE: Water source must provide a minimum of 5 gallons per minute at 20 PSI. High Pressure Hose Hook-up Water Source To reduce the possibility of contamination always protect against backflow when connected to a potable water system. 6. Connect high pressure hose to pump outlet. 7. If applying a chemical or cleaning solution, see How To Apply Chemicals/Cleaning Solvents instructions in this section. 8. Turn water source on. Risk of property damage. Failure to do so could cause damage to the pump. 9. Remove all air from the pump and high pressure hose by depressing trigger until a steady stream of water is present. 10. Start engine. See Engine Owners Manual for correct procedure. 13 - ENG A20118 Risk of unsafe 13. Adjust nozzle spray for the operation. If engine task being performed. See How does not start after two pulls, To Use Wand instructions in this squeeze trigger of gun to relieve section. pump pressure. Pull starter cord slowly until resistance is felt. Then pull cord rapidly to avoid kickback and prevent hand or arm injury. 11. Depress trigger on gun to start water fl ow. Risk of unsafe operation. Stand on a stable surface and grip gun/spray wand firmly with both hands. Expect the gun to kick when triggered. 12. Release trigger to stop water fl ow. Risk of injury from spray. Always engage the trigger lock when gun is not in use. Failure to do so could cause accidental spraying. Trigger Lock Engaged SHUTTING DOWN 1. After each use, if you have applied chemicals, place chemical hose into container of clean water and draw clean water through chemical injection system to rinse system thoroughly. Risk of property damage. Failure to do so could cause damage to the pump. 2. Turn engine off. See Engine Owner’s Manual. Risk of property damage. NEVER turn the water off with the engine running. 3. Turn water source off. 4. Pull trigger on spray gun to relieve any water pressure in hose or spray gun. 5. See Storage section in this manual for proper storage procedures. A20118 14- ENG 15 - ENG A20118 5. Remove dipstick/oil plug and fill with 4.4-4.7 oz (130-140 ml) of EXA70 pump oil. If EXA70 is not available use R&O 150 oil or 30W non detergent oil. 6. Replace oil fi ll cap and tighten securely. NOZZLE CLEANING If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immediately using the nozzle kit supplied and the following instructions: 1. Shut off the pressure washer and turn off the water supply. 2. Pull trigger on gun handle to relieve any water pressure. 3. Disconnect the spray wand from the gun. 4. Release the Gatling turret. Remove any obstructions with the nozzle cleaning tool provided and backfl ush with clean water. 5. Direct water supply into nozzle to backfl ush loosened particles for 30 seconds. 6. Choose nozzle and lock turret into place. 7. Reconnect spray wand to gun and turn on water supply. 8. Start pressure washer and place spray wand into high pressure setting to test. MAINTENANCE Risk of burn hazard. When performing maintenance, you may be exposed to hot surfaces, water pressure or moving parts that can cause serious injury or death. Risk of fi re hazard. Always disconnect, spark plug wire, let the engine cool and release all water pressure before performing any maintenance or repair. The engine contains fl ammable fuel. Do not smoke or work near open fl ames while performing maintenance. To ensure effi cient operation and longer life of your pressure washer, a routine maintenance schedule should be prepared and followed. If the pressure washer is used in unusual conditions, such as high-temperatures or dusty conditions, more fre quent maintenance checks will be required. ENGINE Consult the Engine Owners Manual for the man u fac tur er's recommendations for any and all maintenance. NOTE: The frame is equipped with an oil drain hole to help make changing the engine oil easier. PUMP NOTE: The pump was fi lled with oil at the factory. 1. Change pump oil after the fi rst ten (10) hours of operation and every fi fty (50) hours thereafter. How To Change Pump Oil 1. Loosen oil Oil Fill Plug Oil Drain Plug fi ll cap. 2. Place a container under the oil drain plug. 3. Remove oil drain plug. Use a 5/16" hex wrench. 4. After oil is drained replace oil drain plug. Tighten securely. HOW TO CLEAN THE WATER INLET FILTER This screen filter should be checked periodically and cleaned if necessary. 1. Remove fi lter by grasping end and removing it from water inlet of pump Filter Screen as shown. 2. Clean fi lter by flushing it with water on both sides. 3. Re-insert fi lter into water inlet of pump. NOTE: Cone side faces out. NOTE: Do not operate pressure washer without filter properly installed. STORAGE ENGINE Consult the Engine Owners Manual for the man u fac turer's recommendations f...

Este manual também é adequado para os modelos :
Equipamento de lavagem - Excell XC2800 (5.53 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias