Fabricante : Atlas
Arquivo Tamanho: 440.24 kb
Arquivo Nome : 598-1095-01.pdf
|
Facilidade de uso
• Automatically controls existing post light. • Dual Light Level. • Photocell keeps the light off during daylight hours. This package includes: Post Light Adapter 3 Screws 3 Wire Connectors Requirements • The Light Control requires 120 volts AC. • If you want to use Manual Override, the control must be wired through a switch. • Some codes require installation by a qualified electrician. OPERATION Mode: On-Time Works: Day Night Test 5 Sec x x Auto 1, 5, or 20 Min x Manual To Dawn* x Accent 3,6 Hr, to Dawn x * resets to Auto Mode at dawn. TEST TEST 1 5 20 ON-TIME Off 3 6 Dusk to Dawn ACCENT Put ON-TIME switch on the sensor bottom to TEST and the Dual Light Level (ACCENT) switch OFF. AUTO TEST 1 5 20 MIN Set ON-TIME switch to 1, 5, or 20 minutes. MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one 1 Second second then back on to toggle OFF then... between AUTO and MANUAL MODE. Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position. ... back on. Mode Switching Summary TEST ON-TIME Switch at 1, 5, or 20 minutes AUTO Flip light switch off for 1 second MANUAL MODE then on * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. Dual Light Level Control Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode. 240-031-A © 2003 Atlas Lighting Products, Inc. 598-1095-01 INSTALLATION . Turn power off at circuit breaker. . On existing installations, remove the light from the top of the post. Keep the wire connectors to make the connections to the top of the sensor. CAUTION: When handling the sensor be careful not to pinch or distort the lens. You may break the seal and cause windblown rain to enter the sensor. . Remove the three screws around the bottom edge of the sensor. Save these screws for later use. . Set the controls on the bottom as shown: ON-TIME to TEST, Dual Light Level (ACCENT) OFF, and Sensitivity to mid-position. TEST 20 5 1 DUSK TO DAWN 6 HOUR 3 HOUR OFF MAX. Sensitivity MIN. ON TIME MINUTES ACCENT . Twist the wires from the post and the bottom sensor wires together as shown. Secure with wire connectors provided. . Make sure the wires and connectors are all inside the post, then set the sensor onto the post. . Start and temporarily tighten the three screws previously removed from the sensor. . Twist the wires from the fixture and the top sensor wires together as shown. Secure with wire connectors saved from your fixture. . Make sure all the wires and connectors are inside the fixture/sensor wiring compartment. Set your coach light onto the sensor and proceed to the adjustments on the next page. bare fixture wire White sensor wire to White Black sensor fixture wire wire to Black post wire Green sensor White sensor wire to Black fixture wire Green sensor wire to Green or Red sensor wire to Green or wire to White bare post wire post wire SPECIFICATIONS Range. . . . . . . . . . . Up to 30 ft. (9.1 m) [varies with surrounding temperature] Sensing Angle. . . . . Up to 150°, 360° adjustable Sensor Capacity . . . Up to 360 Watts (3.0 A.) Maximum Power Requirements 120 VAC, 60 Hz Operating Modes . . TEST, AUTO and MANUAL OVERRIDE Time Delay . . . . . . . 1 , 5, 20 minutes Sensitivity . . . . . . . . Adjustable Dual Light Level . . . 3, 6 hours, Dusk-to- Dawn Atlas Lighting Products, Inc. reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. 2 598-1095-01 ADJUSTMENTS . Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching from Manual to Auto mode wait 1 1/2 minute. Avoid aiming the control at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. 5 ft. 150° (1.5 m) 30 ft. (9.1 m) Maximum Maximum Range Coverage Angle The detector is less sensitive to motion directly towards it and more sensitive to across motion. MotionMotion Sensor Least Sensitive Most Sensitive . Walk through the coverage area noting where you are when the lights turn on. Loosen the 3 clamp screws slightly and turn the sensor head left or right to change the coverage area. . When you have the desired coverage angle make a pencil mark on the sensor and post to mark the sensor position. . If you need to change the sensitivity, temporarily lift the fixture and sensor to make the adjustment. It may be necessary to have a friend hol...