Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Agilent Technologies, Modelo 16700 SERIES LOGIC ANALYSIS SYSTEM 16700

Fabricante : Agilent Technologies
Arquivo Tamanho: 3.13 mb
Arquivo Nome : hp_16700a.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


16700 Series Logic Analysis System Product Overview The Agilent Technologies 16700 Series logic analysis systems provide the simplicity and power you need to conquer complex systems by combining state/timing analysis, oscilloscopes, pattern generators, post-processing tool sets, and emulation in one integrated system. Table of Contents System Overview Modular Design page 3 Features and Benefits page 4 Selecting the Right System page 6 Mainframes Display page 7 Back Panel page 8 System Screens page 9 IntuiLink page 12 Probing Solutions Criteria for Selection page 13 Technologies page 14 Data Acquisition and Stimulus State/Timing Modules page 17 Oscilloscope Modules page 30 Pattern Generation Modules page 33 Emulation Modules page 37 Post-Processing and Analysis Tool Sets Software Tool Sets page 39 Source Correlation page 41 Data Communications page 45 System Performance Analysis page 54 Serial Analysis page 61 Tool Development Kit page 67 Licensing Information page 73 Time Correlation with Agilent Infiniium Oscilloscopes E5850A Logic Analyzer - Oscilloscope Time Correlation Fixture page 74 Technical Specifications and Characteristics Mainframe page 75 Probing Solutions page 83 State/Timing Modules page 85 Oscilloscope Modules page 101 Pattern Generation Modules page 104 Trade-In, Trade-Up page 115 Ordering Information page 116 Third-Party Solutions page 123 Support, Warranty and Related Literature page 124 Sales Offices Information page 125 System Overview Modular Design Modular Design Protects Your Long-Term Investment Modularity is the key to the Agilent 16700 Series logic analysis systems' long term value. You purchase only the capability you need now, then expand as your needs evolve. All modules are tightly integrated to provide time-correlated, cross domain measurements. Module Choices State/Timing High-Speed Timing Oscilloscopes User Benefits Agilent offers a wide variety of state/timing modules for a range of applications, from high-speed glitch capture to multi-channel bus analysis. Precisely characterize setup/hold times over a wide channel count. Capture data over many clock cycles while retaining the highest multi-channel accuracy. Identify signal integrity issues and characterize signals quickly with automatic measurements of rise time, voltage, pulse width, and frequency. Pattern Generation Use stimulus to substitute for missing system components or to provide a stimulus-response test environment. Emulation An emulation module connects to the debug port (BDM or JTAG) on your target. You have full access to processor execution control features of the module through the built-in emulation control interface or a third-party debugger. External Ports Target Control Port Use the target control port to force a reset of your target or activate a target interrupt. Port-in/Port-out A BNC connector allows you to trigger or arm external devices or to receive signals that can be used to arm acquisition modules within your logic analyzer. Help enables you to access the online user’s guide and measurement examples. Figure 1.1. The system boot up screen shows you what modules are configured into your logic analysis system. System Overview Features and Benefits System Capability NEW Touch Screen Interface The Agilent 16702B mainframe supports a large, 12.1 inch LCD touch screen and redesigned front panel controls for an easy-to-operate, self-contained unit requiring minimal bench space and offering simple portability. NEW Multiframe Configuration By connecting up to eight mainframes and expanders you can simultaneously view time-correlated traces for all buses in a large channel count, multibus system. NEW Enhanced Mainframe Hardware Mainframe now includes a 40X CD-ROM drive, a 9 GB hard disk drive, 100BaseT-X LAN, and 128 MB of internal system RAM (optional 256 MB total). Scalable System • State/timing analyzers • Select the optimum combination of performance, features, and price that you need for your specific • High-speed timing application today, with the flexibility to add to your system as your measurement needs change. • Oscilloscopes • View system activity from signals to source code. • Pattern generators • Emulation modules Measurement Modules/Interfaces The Agilent 16760A State/Timing Module With up to 1.5 Gb/s state speed, the 16760A lets you debug today’s and tomorrow’s ultra-high-speed digital buses. NEW Eye scan gives a rapid comprehensive overview of signal integrity on hundreds of channels simultaneously The Agilent 16750A, 16751A, and 16752A State/Timing Modules With up to 400 MHz state speed and up to 32 MBytes of trace depth these modules help you address today’s high-performance measurement requirements. (See page 19) The Agilent 16720A Pattern Generator With up to 16 MVectors depth and 300 MVectors/sec operation and up to 240 channels[1] of stimulus, the 16720A provides a new level of capability that makes complex device substitution a reality. Supports TTL, CMOS, 3.3V, 1.8V, LVDS, 3-state,...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias