Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Roland, Modelo DIF-800

Fabricante : Roland
Arquivo Tamanho: 1.88 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If your DM-800 has a version of system software earlier than 2.00, you must have the software upgraded. * For software upgrades, contact a nearby Roland service center. Connecting a DM-800 and an ADAT * Audio tracks 1-8 of the ADAT correspond to digital input/output 1-8 of the DM-800's RMDB connector. As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. ADAT 'nnnmnrfnl ir - SYNC OUT DIGITAL 1 \ DIGITAL OUTPUT/ 1 INPUT DIF-800 SYNC IN/OUT I rPl g ffi Bp. § ADAT ADAT OPTICAL OPTICAL IN OUT DM-800 ADAT 1 a ; ■ ■ ■ m OFF OFF DIF-800 Ç3 E3 «€*522^’ •£§* B i ADAT ADAT OPTICAL OPTICAL IN OUT DM-800 n \RMDB r r -, \hmdb p DM-BOO MW -na o e s o e O m sa ■ ^41 __; o! icn ■“ — ’o' -~.i ; ■ ioio^ojo!©:©;©©. 'o; , ... . ; 0 « © o1« o' rr ~ ^ jf 1; ^4.; :0: ; ¡o;o 010:0:010(9' ¡c ,—, IMIIIii '. .. lUlimill ' Connecting a DM-800 and a DA-88 Note: • When controlling the DM-800 from the DA-88, a Tascam RC-848 remote control unit is required. (If there is no RC-848, the DM-800 cannot be controlled.) • DM-800 synchs to the ABS time(Absolute Time) on the DA-88. • Audio tracks 1-8 of the DA-88 correspond to digital input/output 1-8 of the DM-800's RMDB connector. l.As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. DA-88 SYNC OUT J DIGITAL I/O REMOTE IN/SYNC IN (TO DA-88)/ tof-i M;*n ■ -■ iw ;l; sUels OFF OFF DIF-800 2. Set the DIF-800's device ID knob to a position other than 0 (zero). 3.Set the DA-88's MACHINE ID to 0 (zero). NOTE: Make sure that the DIF-800's device ID and the DA-88's machine ID are not the same. If the IDs are the same, the system may malfunction. l.As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. DA-88 OWKX,___ ooooe e -< tn i* =sz iO 1-1 leloe.eis eo'e; •« —, ■ Mill II ¡1 2. Set the DIF-800's device ID knob to 0 (zero). 3,On the DA-88 that is connected directly to the DIF-800, set the MACHINE ID to 0 (zero). 9 Connecting a DM-800 and a VCR Note: • In order for the DM-800 and the video device to synchronize correctly, the same reference video signal must be provided to the video device and to the DIF-800. ♦ As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. VCR - ♦ As shown in the diagram, connect the devices and set the DIF-800 mode DIP switches. VCR n \HMDB r bwkw».——i— 1 1 / \RMDB _ ftooae e:r-> c.- • \— e ss-r. . ..... a, = 1 © et a • s.es ,e. REFERENCE VIDEO SIGNAL ¡eooeje io. i_ :l;i !© _ " e se e e e« e o illllllllll REFERENCE VIDEO SIGNAL 10 To turn the power on................................ Before you turn on the power of each device, make sure that all devices are connected correctly. Note: To prevent damage to your monitor speakers etc., lower the volume of your audio equipment before turning on any equipment. l.If you are using a video device, turn on the power of the reference video signal source first. 2.Tum on the DIF-800 power. The status indicator will blink green. * When power is turned on, the DIF-800's protection circuit requires a few moments while it readies the unit for normal operation. 3.Tum on the DM-800 power and the power of any SCSI devices connected to the DM-800. The status indicator of the DIF-800 will change to steadily lit green. 4.Tum on the power of your ADAT or DA-88, video device, and audio equipment. 5. While the DM-800 checks the DIF-800 connections, it will display a message like the following. Loading Startup Project-Found DIF-800 Ver.1.00 * Do not connect or disconnect cables while the unit is operating. To turn the power off................................ 1.Turn off the power of the ADAT, DA-88, video device, and audio devices. 2. Perform shut-down operations for the DM-800 and the SCSI devices connected to the DM-800, and turn their power off. 3.Tum off the DIF-800 power. 4. If you are using a video device, him off the source of the reference video signal. 800 Parameter Settings Various parameter settings need to be made on the | 4. Set the Time Base as appropriate for your situation. DM-800 so that control commands can be transmitted and received, and for synchronization to take place. 1.Press [SYSTEM]. The DM-800 will enter System mode. 2. Press [F4] (Page-) or [F5] (Page+) several times to access the Project Parameter 1 screen. Project- P3T3r't0t-0r 1 Sampling Clock source-. Tine Base ............. SMPTE Rate/ForMat ..... Error Level ..... RMDB ■iMaareii 30 - Non 5 Offset Bjjjjggtfige 3.Set the Sampling Clock Source as appropriate for your situation. When using the DIF-800, set this to RMDB. Internal: The sampling clock will be generated from the DM-800 internal clock. Digital IN: The sampling clock will be taken from the digital device connected to the digital input connector. Use this setting when digitally ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias