Log:
Assessments - 5, GPA: 4 ( )

Instruções de Operação Yamaha, Modelo 01V

Fabricante : Yamaha
Arquivo Tamanho: 4.27 mb
Arquivo Nome :
Língua de Ensino: enesca
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


TRANSMIT/RECEIVE DATA 1.1 CHANNEL MESSAGE 1.1.1 NOTE OFF (8n) Reception Received if [Rx CH] matches. Used for EFFECT control. See below for details. STATUS 1000nnnn 8n Note Off Message DATA 0nnnnnnn nn Note No. 0vvvvvvv vv Velocity ( ignored) 1.1.2 NOTE ON (9n) Reception Received if [Rx CH] matches. Used for EFFECT control. See below for details. A velocity of 0x00 is the same as NOTE OFF. STATUS 1001nnnn 9n Note On Message DATA 0nnnnnnn nn Note No. 0vvvvvvv vv Velocity ( 1-127:On, 0:off) * Using Note data for EFFECT control 1: Dynamic Flange/Dynamic Phase/Dynamic Filter When the SOURCE parameter is set to MIDI, Velocity will be used together with Note On/Off to control the frequency width of Modulation. 2: Freeze When PLAY MODE is MOMENT or CONTINUE, a Note On message will start play. However, this is only when the note number specified for MIDI TRG is received. Also, play will not occur if there is no recorded data. Regardless of the Note Number, a Note Off message will stop play if PLAY MODE is MOMENT. 1.1.3 CONTROL CHANGE (Bn) Reception Received when [Control Change RX] is ON and the [Rx CH] matches. However if [OMNI] is ON, this message is received regardless of the channel. When [Control Change ECHO] is ON, this message will be echoed. Parameters will be controlled according to the settings of the [control assign table]. Control of specific faders can be disabled by the [midi fader control input mute] settings. If this message is received while the [control assign table] page is displayed, the cursor location will move to that control number. Transmission If [Control Change TX] is ON, this message is transmitted on the [Tx CH] whenever a parameter specified in the [control assign table] is operated. If [Control Change ECHO] is ON, these messages will be merged with the unit's own output while taking advantage of running status. STATUS 1011nnnn Bn Control Change DATA 0ccccccc cc Control No. ( 0-95, 102-119) 0vvvvvvv vv Control Value (0-127) The control value is converted to the parameter value according to the following equation. C = 128 (byte parameter) 16384 (word parameter) S = number of total possible steps for the parameter C / S = X remainder Y INT((Y+1)/2) = Z If (MIDI DATA - Z) < 0 then -> param = 0 If ((MIDI DATA - Z)/X) > MAX then -> param = MAX In other cases -> param = INT((MIDI DATA -Z)/X) 1.1.4 PROGRAM CHANGE (Cn) Reception Received when [Program Change RX] is ON if the [Rx CH] matches. However if [OMNI] is ON, this is received regardless of the channel. This is echoed if [Program Change ECHO] is ON. A scene memory will be recalled according to the settings of the [Program change table]. Transmission If [Program Change TX] is ON, this is transmitted on the [Tx CH] channel when a scene memory is recalled. If two or more program numbers have been assigned to the memory number which was recalled, the lowest numbered program number will be transmitted. This message is echoed if [Program Change ECHO] is ON. (If a memory number which is not specified in the [Midi Program Change Assign Table] is recalled, the Parameter Change (Function Call) described below will be transmitted.) STATUS 1100nnnn Cn Program Change DATA 0nnnnnnn nn Program No. ( 0-127) 1.2 EXCLUSIVE MESSAGE (F0-F7) 1.2.1 MOTION CONTROL STATE (MCS) MMC STOP/PLAY/FORWARD/REWIND/RECORD/ PAUSE Transmission In the [REMOTE-MMC] page, this is transmitted by key operations. The [DEVICE NO.] specifies the transmission destination. STATUS 11110000 F0 System Exclusive Message ID No. 01111111 7F Real Time System Exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) Command 00000110 06 Machine Control Command(mcc) sub-id 0ccccccc cc Command String [1]:Stop [2]:Play [4]:Fast Forward [5]:Rewind [6]:Record Strobe [9]:Pause EOX 11110111 F7 End Of Exclusive 1.2.2 MOTION CONTROL PROCESS (MCP) MMC LOCATE (target) Transmission In the [REMOTE-MMC] page, this is transmitted by key operations. The [DEVICE NO.] specifies the transmission destination. (The ID of the receiving device must be set.) STATUS 11110000 F0 System Exclusive Message ID No. 01111111 7F Real Time System Exclusive Device ID 0ddddddd dd Destination (00-7E, 7F:all call) Command 00000110 06 Machine Control Command(mcc) sub-id 01000100 44 Locate 00000110 06 byte count 00000001 01 "target" sub command 0hhhhhhh hh hour 0mmmmmmm mm minute 0sssssss ss second 0fffffff ff frame 0sssssss ss sub-frame( only '0') EOX 11110111 F7 End Of Exclusive 01V—Manual de Instrucciones MIDI Data Format 293 MIDI Data Format 293 ACTIVE SENSING (Fe) Reception Once this message has been received, an interval of 300ms or more during which no message is received will cause MIDI communications to be initialized, clearing Running Status etc. STATUS 11111110 FE Active Sensing 2. TRANSMISSION CONDITION CTL Tx ON CONTROL CHANGE $BnH PGM Tx ON PROGRAM CHANGE $CnH SYSTEM EXCLUSIVE PARAM Tx ON PARAMETER CHANGE $F0H, $43H, $1nH (RESPONSE FOR PARAMETER REQUEST) SYSTEM EXCLUSIVE BULK DUMP $F0H, $43H, $0nH BULK REQUEST...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias