Log:
Assessments - , GPA: ( )

Instruções de Operação Yamaha, Modelo ProMix01

Fabricante : Yamaha
Arquivo Tamanho: 986.29 kb
Arquivo Nome :

Língua de Ensino: ende

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere


por este dispositivo também tem outras instruções :

Facilidade de uso


Depends on selected effects type. B. Depends on selected dynamics type. ProMix 01 User’s Guide Add-15 Param # Initial Setup ProMix 01 Parameter Data Value User Setup Control Change # BankControl Change # Bank 480 481 482 0 1 2 5 Oscillator SEND3 Assign 2 Oscillator SEND4 Assign Oscillator ST OUT Assign 483 -- Cue mode MIX/LAST CUE/GROUP CUE/STEREO OUT FIX 4 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 5 Channel Input 1 Group No. (0: OFF, 1–4: A–D) 5 Channel Input 2 Group No. Channel Input 3 Group No. Channel Input 4 Group No. Channel Input 5 Group No. Channel Input 6 Group No. Channel Input 7 Group No. Channel Input 8 Group No. Channel Input 9 Group No. Channel Input 10 Group No. Channel Input 11 Group No. Channel Input 12 Group No. Channel Input 13 Group No. Channel Input 14 Group No. Channel Input 15 Group No. Channel Input 16 Group No. Stereo Input Group No. Panpot Control Mode (Individual/Gang) 2 Group Select (A/B/C/D) 4 “Ch Input 1/2 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” 4 “Ch Input 3/4 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” “Ch Input 5/6 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” “Ch Input 7/8 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” “Ch Input 9/10 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” “Ch Input 11/12 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” “Ch Input 13/14 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” “Ch Input 15/16 Pair Execute(MONO,Odd->Even,Even->Odd,Reset)” Stereo Master Patch Point Pre/Post 2 Send3 Master Patch Point Pre/Post Send4 Master Patch Point Pre/Post “Send3,4 Configuration Execute(Monaural/Stereo)” MIDI Local Off Fader No.1 128 MIDI Local Off Fader No.2 MIDI Local Off Fader No.3 MIDI Local Off Fader No.4 MIDI Local Off Fader No.5 MIDI Local Off Fader No.6 MIDI Local Off Fader No.7 MIDI Local Off Fader No.8 MIDI Local Off Fader No.9 MIDI Local Off Fader No.10 MIDI Local Off Fader No.11 MIDI Local Off Fader No.12 MIDI Local Off Fader No.13 MIDI Local Off Fader No.14 MIDI Local Off Fader No.15 MIDI Local Off Fader No.16 ProMix 01 User’s Guide Add-16 MIDI Data Format 1 General Items 1-1 This section describes the ProMix 01 MIDI specifications. 1-2 Electrical characteristics and signal specifications conform to the MIDI Standard 1.0. 2 Transmission/Reception ProMix 01 transmits and receives Program Change, Control Change, and System Exclusive messages. Real-time messages, Active Sensing, and MIDI Reset are received only. 2-1 Program Change Transmission Channel number (Tx Channel No.) is used for transmission. Messages are received only when the receive Channel number (Rx Channel No.) matches, or when OMNI is set to ON. Receiving a Program Change message recalls the scene memory assigned to that Program number.When a scene memory is recalled using the RECALL button, the corresponding Program Change message is output. Program Changes can be assigned to scene memories by the user. 2-2 Control Change Control Change messages can be transmitted and received in Channel mode or Register mode. In Channel mode, the MIDI Channel No. is the Transmission/Receive Channel (Tx/Rx Channel No.) plus parameter Bank Number( Bank). If the resultant value exceeds 16, the remainder will be the Channel number. If all parameters are transmitted and received in this mode, many MIDI Channels are used. See below. In Register mode, the Channel number uses the transmission/receive Channel number (Tx/Rx Channel No.), and the parameter Bank Number(Bank) is specified by Non-Registered Parameter Number(NRPN) 62h (98 in decimal). In this mode, only one MIDI Channel is required, and OMNI operation is available. See below. The ProMix 01 parameter corresponding to the Control Change Bank number and Control Change number is adjusted. If an assigned parameter is adjusted using the front panel controls, the corresponding Control Change message is output. Parameters can be assigned to Control Changes by the user. The data format will be as follows: When you adjust a parameter of Channel #10, Bank #2, and Control #72: BB 48 dd (dd is data) When you adjust a parameter of Channel #13, Bank #5, and Control #20: B1 14 dd (dd is data) The data format will be as follows: When you adjust a parameter of Channel #10, Bank #2, and Control #72: B9 62 02 B9 48 dd (dd is data) For MIDI data transmission, a parameter’s minimum internal data value is expressed by 00h, and the maximum value is expressed by 7fh. For example, for Panpot data the internal data value “0” is expressed by 00h, and the internal data value “32 (MAX)” is” expressed by 7fh. ProMix 01 User’s Guide Add-17 To derive the midway value of the internal data, the following calculation is used (MIDI midway value = 64). First, 128 (the maximum value use...

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias