Install the regulator on the end of the manifold using the short pipe hippie. The arrow on the bottom of the regulator must point away from the manifold in order for the regulator to function properly'. Next, install the gauge, adapter and plug in the regulator. The ptug is supplied with the regulator. BREAK= N PROCEDURES ° the minimum wire size is t2 gauge (AWG}. Sears #9 83606, 12 gauge x 50' extension cord is available at your local Sears Service Center. (Wire size increases as gauge number decreases. 10AWG and 8 AWG may also be used. DO NOT USE !4 AWG or 16 AWG.) Lubrication and OH Compressors are shipped without oil Do not attempt to operate this air compressor without first adding oi_ to the crankcaaeo P!ace unit on a levet surface. Remove oil fill plug (Key no. 81, pg. 15) and slowly add a speciat compressor oil such as Sears 9-16426 or SAE 20_20W SF motor oil until it is even with the top of the oi! fill hole. (it must not be aliowed to be Iower than 3/8"-6 threads down -from the top, at any time.) When ill!rig the crankcase, the oil flows vary slowly. If the oil is added too quickly, it will overflow and appear to be full. Crankcase oiI capacity is 16 fad ounces. Under winter-type conditions use SAE 10W oil. Multi-viscosity oil, 10W 30_witl teave carbon deposits on critical components reducing performance and compressor iife. Reptace oil fill plug. Grounding _nstructions iMPROPER GROUNDING CAN RESULT tN ELECTRICAL SHOCK= IN THE EVENT OF A SHORT CIRCUIT, GROUNDING REDUCES THE RiSK OF SHOCK BY PROViDiNG AN ESCAPE WiRE FOR THE ELECTRIC CURRENT, THIS A_R COMPRESSOR MUST BE PROPERLY GROUNDED. 1. The air compressor is equipped with a cord having a grounding wire and an appropriate grounding plug= The plug must be used with an outlet that has been installed and grounded in accordance with alt local codes and ordinances. The outlet must have the same configuration as the plug. DO NOT USE AN ADAPTER. 2. Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified electrician. 3. Inspect the plug and cord before each use. Do not use the compressor if there are signs of damage. ELECTRICAL SHOCK HAZARD. WHEN REPAmRING OR REPLACING THE CORD OR PLUG, KEEP THE GROUNDING W_RE SEPARATE FROM THE CURRENToCARRYmNG W_RES. NEVER CONNECT THE GROUNDgNG W_RE TO A FLAT BLADE PLUG TER= MINAL, (THE GROUNDING W_RE HAS INSULATION WITH AN OUTER SURFACE THAT IS GREEN -WSTH OR W_THOUT YELLOW STRIPES.) OPERATING 1. Before attaching an air hose or accessory', make sure the pressure switch lever is in the "OFF" position. Close the air regulator outlet by turning it counter-clockwise. TOO MUCH AmR PRESSURE CAUSES A HAZARDOUS R_SK OF BURSTING, CARE_ FULLY FOLLOW STEPS 3 THROUGH !2 EACH TmMETHE COMPRESSOR IS USED, 3. Check the manufacturer's maximum pressure rating for air tools and accessories. The reguator outlet p...
Este manual também é adequado para os modelos :equipamento de bombagem - 919.176730 (1.37 mb)
equipamento de bombagem - 919.17673g (1.37 mb)