Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação York, Modelo E*BD-(T

Fabricante : York
Arquivo Tamanho: 216.45 kb
Arquivo Nome : 2434a3b4-7203-4b9b-8711-2b9332269305.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Rated CFM same as for cooling. 2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. CP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. — = Not Applicable. Unitary Products Group 246819-BTG-H-0208 ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit (2SA067*) Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied. Hard Start Kits -Provides required starting torque for use with Thermal Expansion Valve Kit. Low Temperature Cutout (2LT06700224) - Prevents heat pump operation below -10°F ambient temperature. Compressor Blanket - Designed to further reduce the nor mal operating sound. Add-on Fossil Fuel Control - Interface controls for use with gas, oil furnaces and the heat pump system are available. Thermal Expansion Valve Kit - 1TVM700 Series TXV kit used to improve system performance. Outdoor Thermostat (2TD06700124) -Provides additional staging of supplemental electric heat. INSTALLATION CLEARANCES Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. 2H/1C, manual changeover electronic non-programmable thermostat. 3H/2C, non-programmable digital thermostat. 3H/2C, auto/manual changeover, electronic programmable, 7-day, hardwire thermostat. * For the most current accessory information, refer to the price book or consult factory. SOUND POWER RATINGS UNIT MODEL (dBA)* Cooling Heating 018 73 72 024 75 76 030 74 76 036 76 77 042 77 78 048 78 78 060 79 79 * Rated in accordance with ARI 270-95 Standards. MINIMUM18”SERVICEACCESSCLEARANCEONONESIDE60”OVERHEADCLEARANCE10”CLEARANCECOILAREAWEATHERPROOFDISCONNECTSWITCHTHERMOSTATTOFURNACEORAIRHANDLERTERMINALBLOCKNECCLASS1WIRINGNECCLASS2WIRINGTOINDOORCOILSEALOPENING(S)WITHPERMAGUMOREQUIVALENTCONTROLACCESSPANELNOTE:ALLOUTDOORWIRINGMUSTBEWEATHERPROOF. TYPICAL FIELD WIRING THERMOSTAT INDOOR UNIT DEFROST CONTROL 1 FIELD INSTALLED JUMPER DEHUMIDIFICATION CONTROL CONNECTION (Humidistat* Jumper must be removed) GND. SCREW CONTACTOR T2 T1 L2 L1 M R L or X Y O W G T2 E2 R R Y Y OO W2 W W1 C C X/L G W1 BK GND. LUG CIRCUIT BREAKER*** POWER WIRING 24V CONTROL WIRING (NEC CLASS 2) JUMPER TERMINALS E AND W TOHEAT ON FIRST STAGE DURING EMERGENCY HEAT. TERMINAL NOT USED ON ALL THERMOSTATS. POWER WIRING 208/230-1-60 230-1-50 3CHECK THE LOW VOLTAGE TERMINAL BLOCK ON THE INDOOR UNIT FOR THE ACTUAL ARRANGEMENT OF THE TERMINALS. 4 CONNECT POWER WIRING TO TERMINAL BLOCK 3TB ON UNITS WITHOUT ELECTRIC HEAT OR CIRCUIT BREAKER. B or C ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES RED BLK YEL ORG BRN PUR WHT CCGRY /66 5 GRAY FOR USE WITH OPTIONAL OUTDOOR THERMOSTAT KITS. 5 Unitary Products Group 246819-BTG-H-0208 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. EABD-F018S INDOOR COIL MODEL NO. FC/MC/PC/UC18 CONDENSER ENTERING AIR TEMPERATURE ID CFM 450 600 750 ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 65 T.C. 16.8 19.2 19.5 21.9 24.5 19.0 20.7 20.8 23.1 25.8 21.2 22.3 22.1 24.3 27.1 S.C. 16.3 14.4 12.7 12.8 10.8 18.4 16.9 14.7 14.6 12.3 20.6 19.5 16.8 16.4 13.8 K.W. 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 75 T.C. 16.1 18.1 18.3 20.6 23.2 18.1 19.5 19.4 21.8 24.3 20.1 20.9 20.6 23.0 25.4 S.C. 15.6 13.9 12.1 12.3 10.3 17.6 16.3 14.1 14.0 11.7 19.5 18.8 16.0 15.8 13.0 K.W. 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 85 T.C. 15.4 17.1 17.0 19.2 21.8 17.2 18.3 18.1 20.4 22.7 19.0 19.6 19.2 21.6 23.6 S.C. 14.9 13.4 11.5 11.7 9.8 16.7 15.7 13.4 13.5 11.0 18.5 18.1 15.3 15.3 12.2 K.W. 1.2 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.4 95 T.C. 14.8 16.0 15.8 17.9 20.4 16.3 17.1 16.8 19.1 21.2 17.9 18.3 17.7 20.3 21.9 S.C. 14.2 12.9 10.9 11.1 9.3 15.8 15.1 12.7 12.9 10.4 17.5 17.4 14.6 14.7 11.4 K.W. 1.3 1.3 1.3 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.5 105 T.C. 14.0 14.9 14.7 16.8 19.1 15.4 16.0 15.6 17.8 19.7 16.9 17.0 16.5 18.7 20.4 S.C. 13.5 12.5 10.4 10.7 8.8 15.0 14.5 12.2 12.4 9.9 16.4 16.6 14.0 14.1 10.9 K.W. 1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 115 T.C. 13.3 13.9 13.7 15.7 17.8 14.5 14.9 14.5 16.4 18.4 15.8 15.8 15.3 17.2 19.0 S.C. 12.8 12.0 9.9 10.2 8.3 14.1 13.9 11.7 11.8 9.4 15.4 15.8 13.4 13.4 10.5 K.W. 1.5 1.5 1.5 1.6 1.6 1.5 1.6 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.7 125 T.C. 12.5 12.9 12.7 14.6 16.5 13.7 13.7 13.4 15.1 17.0 14.8 14.5 14.1 15.7 17.5 S.C. 12.0 11.6 9.4 9.8 7.8 13.2 13.3 11.1 11.3 8.9 14.4 15.1 12.8 12.8 10.0 K.W. 1.6 1.6 1.6 1.7 1.7 1.6 1.6 1.6 1.7 1.7 1.7 1.7 1.7 1.7 1.8 NOTE: A...

Este manual também é adequado para os modelos :
equipamento de bombagem - E*BD-F018 THRU 060 (216.45 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias