Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação York, Modelo E*BD-F018 THRU 060

Fabricante : York
Arquivo Tamanho: 216.45 kb
Arquivo Nome : 2434a3b4-7203-4b9b-8711-2b9332269305.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Visit us on the web at Additional rating information can be found at DESCRIPTION The 13 SEER series heat pumps are designed for use with a variety of UPG evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. MatchingAir Handlers are also available for upflow, downflow or horizontal installation to provide a complete system. Electric heat may be installed in air handlers. All units are factory charged to assure easy installation. WARRANTY Single Phase Units: 5-year limited parts warranty. 5-year limited compressor warranty. Three Phase Units: 1-year limited parts warranty. 5-year limited compressor warranty. FEATURES • DURABLE CONSTRUCTION -The outdoor unit is constructed of pre-painted steel that offers tough protectionagainst corrosion and resists fading when exposed to sunlight. Drain holes are incorporated into the base pan to permit free drainage of moisture. • QUALITY COILS -The coil is constructed of enhanced copper tube and aluminum fins. • COIL PROTECTION -Coils are protected from damage bya polymer mesh applied between the coil face, and a PVCcoated steel coil guard. • PROTECTED COMPRESSOR -The hermetic compressoris internally protected against high pressure and temperature by the simultaneous operation of a high pressure reliefvalve and temperature sensors which stop the compressorif operating temperatures go too high. Both protectorsreset automatically. A discharge line solid core filter drierfurther protects the compressor. • Complete System Control – These heat pumps utilizethe unique microprocessor defrost control system to provide optimal comfort and to monitor the overall system forreliable operation. The defrost control system continuouslymonitors the space environment to maintain optimum efficiency. It initiates defrost only when necessary to furtherreduce heating costs and improve reliability. In the eventimproper operating conditions occur, the control will automatically shut the system down to extend the life of theheat pump. Rapid cycling is prevented by use of an internal anti-recycle timer. • LOW OPERATING SOUND LEVEL -The compressor ismounted on rubber isolators to reduce operating sounds. The slow moving condenser fan keeps air turbulence andsound to a low level. • EASY ACCESS -Removable panel affords accessibility tothe electrical box. • FULLY CHARGED AND FACTORY WIRED -to simplyinstallation and reduce labor costs. Only power supply andcontrol wiring and refrigerant lines must be connected. Allmodels are sweat connect with reusable service valves. • Factory tested - to verify system operation and controlfunctioning before shipment. • U.L. and C.U.L. listed - approved for outdoor application. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 246819-BTG-H-0208 Physical and Electrical Data -1 Phase MODEL EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Unit Supply Voltage 208-230V, 1., 60Hz Normal Voltage Range 1 187 to 252 Minimum Circuit Ampacity 9.9 15.0 16.9 19.8 25.0 32.7 37.8 Max. Overcurrent Device Amps 2 15 25 25 30 40 50 60 Min. Overcurrent Device Amps 3 15 20 20 20 30 35 40 Compressor Type 4 Recip Recip Recip Recip Recip ScrollD ScrollD Compressor Amps Rated Load 7.5 10.7 12.4 14.6 18.8 25.0 29.1 Locked Rotor 41 44 60 78 78 115 150 Crankcase Heater Yes Yes Yes Yes Yes No No Fan Motor Amps Rated Load 0.5 1.5 1.5 1.5 1.5 1.5 1.5 Fan Diameter Inches 22 22 22 22 22 24 24 Fan Motor Rated HP 1/15 1/4 1/4 1/4 1/4 1/4 1/4 Nominal RPM 850 850 850 850 850 850 850 Nominal CFM 2,000 3,250 3,450 3,500 3,500 3,400 3,500 Coil Face Area Sq. Ft. 15.72 18.34 20.96 23.58 23.58 24.00 27.00 Rows Deep 1 1 1 1 1 2 2 Fin / Inches 22 22 22 22 22 18 18 Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed) 3/4 3/4 7/8 7/8 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) 5 7 - 1 6 - 6 8 - 7 8 - 7 8 - 7 12 - 8 16 - 7 Charge Per Foot, Oz. 0.68 0.68 0.70 0.70 0.70 0.70 0.76 Operating Weight Lbs. 172 184 196 208 208 250 294 1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection. 3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection. 4. All scrolls listed with a superscript “D” are Danfoss scrolls. All scrolls listed with a superscript “C” are Copeland scrolls. 5. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. ABC All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. Un...

Este manual também é adequado para os modelos :
equipamento de bombagem - E*BD-(T (216.45 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias