Log:
Assessments - 5, GPA: 4 ( )

Instruções de Operação Porter-Cable, Modelo D24938-044-2

Fabricante : Porter-Cable
Arquivo Tamanho: 904.49 kb
Arquivo Nome : f798e604-16f4-420e-80d4-a32d18ca0a97.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


See "Oil" paragraph in the "Maintenance" section for instructions. 3. Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.) 4. Open the drain valve fully to permit air to escape and Open Drain prevent air Valve pressure build up in the air tank during the break- in period. 5. Move the On/Auto/Off lever to "On/Auto" position. The compressor will start. 15- ENG D24938 6. Run the compressor for 20 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank. 7. After 20 minutes, close the drain valve. The air receiver will fill to "cut-out" pressure Closed Drain and the motor will Valve stop. The compressor is now ready for use. Before Each Start-Up: 1. Place On/Auto/Off lever to "Off". 2. Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. 3. Attach hose and accessories. Risk of Bursting. Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating. How to Start: 1. Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use. D24938 16- ENG MAINTENANCE Customer Responsibilities Before each use Daily or after each use Every 8 hours Every 40 hours Every 100 hours Every 160 hours Yearly Check Safety Valve . Drain Tank . Oil Leaks . Check Oil . Change Oil . Unusual Noise and/or Vibration . Air Filter .1 Drive Belt-Condition . Motor Pulley/Flywheel alignment . Air compressor pump intake and exhaust valves . Head Bolts - Check the torques of the head bolts after the first five hours of operation. 1- more frequent in dusty or humid conditions Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure. To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The above routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks. NOTE: See "Operation" section for the location of controls. To Check Safety Valve 1. Before starting compressor, pull the ring on the safety valve to If the safety valve make sure that the safety valve does not work operates freely. If the valve is properly, over-pressurization may stuck or does not operate occur, causing air tank rupture or smoothly, it must be replaced an explosion. with the same type of valve. 17- ENG D24938 To Drain Tank NOTE: Operation of the air compressor will cause condensation to build up in the air tank. Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces. 1. Set the On/Auto/Off lever to "Off". 2. Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 5. Drain water from air tank by opening drain valve on bottom of Open Drain tank. Valve Risk of Bursting. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 6. After the water has been drained, close the drain valve. The air compressor can Closed Drain now be stored. Valve NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled. A B Oil NOTE: Use an oil specifically formulated for use in an air compressor, such as Porter-Cable PAS1 air compressor oil. Oil may be found at the store where the air compressor was purchased. NOTE: Crankcase oil capacity is approximately 16 fluid ounces. Checking 1. Remove the oil fill plug (A). The oil level should be even with the top of the fill hole and no lower than 6 threads from the top of fill hole. 2. If needed, slowly add oil until it reaches the top of fill hole. Changing 1. Remove the oil fill plug (A). 2. Remove the oil drain plug (B) and drain oil into a suitable container. 3. Replace the oil drain plug (B) and tighten securely. 4. Slo...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias