Instruções de Operação Hearth and Home Technologies, Modelo MT VERNON Pellet Insert Advanced Energy (AE) MTVERNINSAE-CWL

Fabricante : Hearth and Home Technologies
Arquivo Tamanho: 5.21 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Ensure that the leveling leg is positioned over the 2 x 4 before leveling the insert. September 1, 2008 7036-135E Page 11 Mt. Vernon Pellet Insert (AE) 4 44V VVent Information ent Informationent Information A. Venting Termination Minimum Requirements R J or XV M I HA V G B V V A B V F V C B B E L V D V Electrical Ser ice V NV N V N N V Inside orner FIXED CLOSEDOPEN OPEN FIXED CLOSED V X G GTermination Cap Air Supply Inlet Gas Meter Restricted Area O P Figure 12.1 All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. A 12 in. Above Finish Grade (the grade surface must be a non-combustible material B 12 in. 48 in. no OAK Open door or window: below or to the side B 12 in. Open door or window: above C 6 in. Permanently closed window: above, below or to the side D 18 in. 36 in. no OAK Vertical clearance to a ventilated soffit located above the terminal within a horizontal distance of 2 ft from the center-line of the terminal E 12 in. Clearance to unventilated soffit F 12 in. Clearance to outside corner G 12 in. Clearance to inside corner H 36 in. Above gas meter/regulator measured from horizontal center-line of regulator I 36 in. USA 72 in. Canada Clearance to service regulator vent outlet J 12 in. 48 in. no OAK Clearance to non-mechanical air supply inlet to the building or the combustions air inlet to any other appliance K 10 ft horizontal 3 ft vertical Clearance to mechanical air supply L 7 ft. Above paved sidewalk, paved driveway located on public property M 12 in. Under an open veranda, porch, deck or balcony N See Note below* Electric service: above, below or to the side (location must not obstruct or interfere with access) O 24 in. Adjacent building, fences and protruding parts of the structure P 12 in. Clearance above roof line for vertical terminations *NOTE: Consult local building, fire officials or authorities having jurisdiction. Local codes or regulations may require different clearances. 24 in. Above grass, top of plants, wood or any other combustible 12 in. 36 in. no OAK Clearance from any forced air intake of other appliance 12 in. Clearance horizontally from combustible wall 15 in. Vented directly through a wall, minimum length of horizontal pipe 6 in. horizontal 12 in. vertical Minimum horizontal or vertical terminations must protrude from wall NOTICE: Do NOT Terminate Vent: • In any location that will allow flue gases or soot from entering or staining the building. • In any location which could create a nuisance or hazard. • In any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway. • Closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etc. NOTICE: Termination must exhaust above air inlet elevation. • It is recommended that at least 60 inches (1524mm) of vertical pipe be installed when appliance is vented directly through a wall. This will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage. • It will also keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. • The safest and preferred venting method is to extend the vent vertically through the roof or above the roof. Page 12 7036-135E September 1, 2008 R September 1, 2008 7036-135E Page 13 Mt. Vernon Pellet Insert (AE) B. Chimney and Exhaust Connection 1. Chimney & Connector: Use 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system. It can be vented vertically or horizontally. 2. Mobile Home: Approved for all Listed pellet vent. Use Listed double wall flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations. 3. Residential: Use 24 gauge single wall flue connector or Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting International Residential Code standards for solid fuel appliances. 4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. 5. Secure exhaust venting system to the appliance with at least 3 screws. Also secure all connector pipe joints with at least 3 screws through each joint. NOTE: All pipe must be welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only). NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instructions from the venting manufacturer. Fire Risk. • Only LISTED venting components may be used. • NO OTHER vent components may be used. Substitute or damaged vent components may impair safe operation. WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or your dealer. WARNING T...

Este manual também é adequado para os modelos :
Placa - MT VERNON Pellet Insert Advanced Energy (AE) MTVERNINSAE-CSB (5.21 mb)
Placa - MT VERNON Pellet Insert Advanced Energy (AE) MTVERNINSAE-MBK (5.21 mb)
Placa - MT VERNON Pellet Insert Advanced Energy (AE) MTVERNINSAE-PMH (5.21 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias