2 Back View ............................................................. 3 Remote Sensor ..................................................... 3 Getting Started.......................................................... 3 Insert Batteries ...................................................... 3 Remote Sensor ......................................................... 4 Sensor Data Transmission .................................... 4 Clock.......................................................................... 5 Clock Reception .................................................... 5 Manually Set Clock ............................................... 5 Weather Forecast ..................................................... 6 Weather Warning Message...................................... 6 Temperature and Humidity......................................6 Ice Warning ........................................................... 6 Weather Trends ..................................................... 7 Moon Phase .............................................................. 7 Backlight ................................................................... 7 Reset.......................................................................... 7 Precautions............................................................... 7 Specifications ........................................................... 8 About Oregon Scientific .......................................... 8 EU-Declaration of Conformity ................................. 8 1 EN OVERVIEW FRONT VIEW (FIG 1) EN OVERVIEW FRONT VIEW (FIG 1) 1. Remote sensor reception indicator 2. Moon phase reading 3. Weather forecast 4. Indoor temperature with temperature trend 5. Clock signal reception indicator 6. MODE: Change settings / display 7. / : Increase / decrease settings; activate / deactivate clock reception signal 8. Outdoor temperature with temperature trend 9. Outdoor humidity with humidity trend 10. Weather warning message 11. Indoor humidity with humidity trend 12. Clock with weekday 13. MEM: View current, maximum and minimum temperature / humidity 14. LIGHT: Activate backlight for 5 seconds 15. Ice alert LED indicator 2 EN BACK VIEW (FIG 2) REMOTE SENSOR (FIG 3) EN BACK VIEW (FIG 2) REMOTE SENSOR (FIG 3) 12 1. °C / °F: Select temperature unit 2. EU / UK: Select the nearest radio signal 3. RESET: Reset unit to default settings 2 1 4 3 5 1. LED status indicator 3 2. 3. Wall mount hole Battery compartment 4. RESET hole 5. CHANNEL switch GETTING STARTED INSERT BATTERIES 1. Remove the battery compartment. 2. Insert the batteries, matching the polarities (see FIG 2). 3. Press RESET after each battery change. 3 1.5m(5ft)1.5m(5ft) EN LOCATION MEANING Clock / alarm and Indoor temperature area Main unit batteries low Outdoor temperature area Sensor batteries low REMOTE SENSOR The main unit can collect data from up to 3 sensors. To set up the sensor: 1. Open the battery compartment (see FIG 3). 2. Select a channel then press RESET. 3. Close the battery door. 4. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount. TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading. NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing. SENSOR DATA TRANSMISSION To search for a sensor: Press and hold + MODE. The sensor reception icon in the remote sensor area shows the status: 4 ENEN reception is unsuccessful, place your unit next to a window, press and hold to force another signal search. Clock signal reception indicator: STRONG SIGNAL WEAK SIGNAL NO SIGNAL ICON DESCRIPTION Main unit is searching for sensor(s). A channel has been found. The sensor cannot be found. TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results. CLOCK CLOCK RECEPTION This product is designed to synchronize its clock automatically with a clock signal. Slide EU / UK to select the signal received. • EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany. • UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England. To enable / disable signal reception: Press and hold to enable or to disable signal reception. NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up to 24 hours to get a valid signal. If signal MANUALLY SET CLOCK To set the clock manually, disable the signal reception first. 1. Press and hold MODE. 2. Press or to change the settings. 3. Press MODE to confirm. 4. The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (day – month / month – day), month, day and language. Time zone offset sets the clock +/- 23 hours from the received clock signal time. NOTE The language options are English (E), German (D), French (F), Itali...