Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Omega, Modelo CNI8DH

Fabricante : Omega
Arquivo Tamanho: 1.2 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Press d 2) Display advances to INPT Input Menu. Press d 3) Display flashes T.c, RTD or PROC (Thermocouple, RTD or Process). If the displayed input type is T.c, press a to skip to step 6 (T.c stops flashing). THERMOCOUPLE SUBMENU: Press b 4) Scroll through the available selection to T.c (flashing). Press d 5) Display shows STRD stored message momentarily and then T.c (not flashing). Press d 6) Display flashes previous thermocouple type selection. i.e. J (see below for types). Press b 7) Scroll through the available thermocouple types to the selection of your choice. Press d 8) Display shows STRD stored message momentarily and then advances to the RDG Reading Configuration Menu. Use the Input Type (Thermocouple) (RTD) or (Process) and verify your Electrical Installation (see section 2.3). Thermocouple Types: J,K, T, E,N,DIN J,R,S,B, C Display: JKTEN DNJ RSBC 19 Input Type (RTD) ENTER INPUT TYPE MENU: Press a 1) Press a, if necessary, until CNFG prompt appears. Press d 2) Display advances to INPT Input Menu. Press d 3) Display flashes T.c, RTD or PROC (Thermocouple, RTD or Process). If the displayed input type is RTD, press a to skip to step 6 (RTD stops flashing). RTD SUBMENU: Press b 4) Scroll through the available selection to RTD (flashing). Press d 5) Display shows STRD stored message momentarily and then RTD (not flashing). Press d 6) Display flashes previous RTD type selection i.e. 392.2 (see below for RTD types selection). Press b 7) Scroll through the available RTD types to the selection of your choice. Press d 8) Display shows STRD stored message momentarily and then advances to RTD RTD value. RTD Types: 392 385 Two, Three or Four-wire Display: 392.2, 392.3, 392.4, 385.2, 385.3, 385.4 Last digit indicates: 2-, 3- or 4-wire input. RTD VALUE SUBMENU: Press d 9) Display flashes previous RTD value selection i.e. 100_ (see below for RTD value selection). Press b 10) Scroll through the available RTD values to the selection of your choice. Press d 11) Display shows STRD stored message momentarily and then advances to RDG Reading Configuration Menu. RTD Values: 100 ohm 500 ohm 1000 ohm Display: 100_ 500_ 1000 20 Input Type (Process) ENTER INPUT TYPE MENU: Press a 1) Press a, if necessary, until CNFG prompt appears. Press d 2) Display advances to INPT Input Menu. Press d 3) Display flashes T.c, RTD or PROC (Thermocouple, RTD or Process). If the displayed input type is PROC, press a to skip to step 6 (PROC stops flashing). PROCESS SUBMENU: Press b 4) Scroll through the available selection to PROC (flashing). Press d 5) Display shows STRD stored message momentarily and then PROC (not flashing). Press d 6) Display flashes previous Process type selection. i.e. 0-10 (see below for Process types selection). Press b 7) Scroll through the available Process types to the selection of your choice. Press d 8) Display shows STRD stored message and then advances to RDG Reading Configuration Menu. Process Types: 100 mV 1 V 10 V 0 – 20 mA Display: 0-0.1 0-1.0 0-10 0-20 For 4-20 mA Input select 0-20 mA then adjust the Input/Reading accordingly. To adjust 4-20 mA input, see example under INPUT/READING submenu. The factory preset value is 4-20 mA. 3.2.5 Reading Configuration It is required that you put the controller in the Standby Mode for any configuration change other than Set Points & Alarms. Figure 3.4 Flow Chart for Reading Configuration Menu 21 ENTER READING CONFIGURATION MENU: Press a 1) Press a, if necessary, until CNFG prompt appears. Press d 2) Display advances to INPT Input Menu. Press a 3) Display advances to RDG Reading Configuration Menu. Press d 4) Display advances to DEC Decimal Point. DECIMAL POINT SUBMENU: Press d 5) Display flashes previous selection for Decimal location. Press b 6) Scroll though the available selections and choose Decimal location: FFFF or FFF.F (also FF.FF and F.FFF — if PROC Process type was selected in the Input Type Menu). Press d 7) Display shows STRD stored message momentarily and then advances to TEMP Temperature Unit. Decimal Point for Process Input Type is passive. TEMPERATURE UNIT SUBMENU: Press d 8) Display flashes previous Temperature Unit selection. Press b 9) Scroll though the available selections to the Temperature Unit of your choice: °F or °C. Press d 10) Display shows STRD stored message momentarily and then advances to FLTR Filter Constant. FILTER CONSTANT SUBMENU: Press d 11) Display flashes previous selection for Filter Constant. Press b 12) Scroll though the available selections: 0001, 0002, 0004, 0008, 0016, 0032, 0064, 0128 Press d 13) Display shows STRD stored message momentarily only, if change was made, otherwise press a to advance to the next menu. If Process was selected in the Input Type Menu the display will advance to IN.RD Input/Reading Submenu, otherwise the display advances to the ALR1 Alarm 1 Menu. The Filter Constant Submenu allows the user to specify the number of readings stored in the Digital Averaging Filter. For PID control select filter value 0001-...

Este manual também é adequado para os modelos :
Estação Meteorológica - CNI8 (1.2 mb)
Estação Meteorológica - CNI8C (1.2 mb)
Estação Meteorológica - CNI8DV (1.2 mb)
Estação Meteorológica - CNI16 (1.2 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias