Instruções de Operação Omega, Modelo CNI8DV

Fabricante : Omega
Arquivo Tamanho: 1.2 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Do not attempt to change these parameters. LINE FEED SUBMENU: Determines if data sent from the instrument will have a Line Feed appended to the end - useful for viewing or logging results on separate lines when displayed on communications software at a computer. Press d 22) Display flashes previous selection for “Line Feed”. Press b 23) Scroll through the available selections: NO, YES. Press d 24) Display shows STRD stored message momentarily and then advances to ECHO only, if it was changed, otherwise press a to advance to ECHO Echo Submenu. ECHO SUBMENU: When valid commands are sent to the instrument, this determines whether the command will be echoed to the Serial Bus. Use of echo is recommended in most situations, especially to help verify that data was received and recognized by the controller. 51 Press d 25) Display flashes previous selection for “Echo”. Press b 26) Scroll through the available selections: NO, YES. Press d 27) Display flashes STRD stored message momentarily and then advances to STND only if it was changed, otherwise press a to advance to STND Communication Standard Submenu. COMMUNICATION INTERFACE STANDARD SUBMENU: Determines whether device should be connected to an RS-232C serial port (as is commonly used on IBM PC-compatible computers) or via an RS-485 bus connected through appropriate RS-232/485 converter. When used in RS-485 Mode, the device must be accessed with an appropriate Address Value as selected in the Address Submenu described later. Press d 28) Display flashes previous selection for “Standard”. Press b 29) Scroll through the available selections: 232C, 485. Press d 30) Display shows STRD stored message momentarily and then advances to MoDE only, if it was changed, otherwise press a to advance to MoDE Data Flow Mode Submenu. DATA FLOW MODE SUBMENU: Determines whether the instrument will wait for commands and data requests from the Serial Bus or whether the instrument will send data automatically and continuously to the Serial Bus. Devices configured for the RS-485 Communications Standard operate properly only under Command Mode. Press d 31) Display flashes previous selection for “Mode”. Press b 32) Scroll through the available selections: CMD_ __ “Command”, CoNT “Continuous”. Press d 33) Display shows STRD stored message momentarily and then advances to SEPR only, if it was changed, otherwise press a to advance to SEPR Data Separation Submenu. DATA SEPARATION CHARACTER SUBMENU: Determines whether data sent from the device in Continuous Data Flow Mode will be separated by spaces or by Carriage Returns. Press d 34) Display flashes previous selection for “Separation” Submenu. Press b 35) Scroll through the available selections: SPCE “Space” or _cR_ “Carriage Return”. Press d 36) Display shows STRD stored message momentarily and then advances to DAT.F only, if it was changed, otherwise press a to advance to DAT.F Data Format Submenu. 52 DATA FORMAT SUBMENU: Preformatted data can be sent automatically or upon request from the controller. Use the Data Format Submenus to determine what data will be sent in this preformatted data string. Refer to the iSeries Communications Manual for more information about the data format. At least one of the following suboptions must be enabled and hence output data to the Serial Bus. This menu is applicable for Continuous Mode of RS-232 communication. Press d 37) Display advances to STAT Alarm Status Submenu. ALARM STATUS SUBMENU: Includes Alarm Status bytes in the data string. Press d 38) Display flashes previous selection for “Status” (alarm status). Press b 39) Scroll through the available selections: NO, YES. Press d 40) Display shows STRD stored message momentarily and then advances to RDNG only, if it was changed, otherwise press a to advance to RDNG Reading Submenu. MAIN READING SUBMENU: Includes Main Reading in the data string. Press d 41) Display flashes previous selection for “Reading”. Press b 42) Scroll through the available selections: NO, YES. Press d 43) Display shows STRD stored message momentarily and then advances to PEAK only, if it was changed, otherwise press a to advance to PEAK Peak Submenu. PEAK VALUE SUBMENU: Includes Peak Value in the data string. Press d 44) Display flashes previous selection for PEAK Submenu. Press b 45) Scroll through the available selections: NO, YES. Press d 46) Display shows STRD stored message momentarily and then advances to VALY only, it was changed, otherwise press a to advance to VALY Valley Submenu. VALLEY VALUE SUBMENU: Includes Valley Value in the data string. Press d 47) Display flashes previous selection for “Valley”. Press b 48) Scroll through the available selections: NO, YES. Press d 49) Display shows STRD stored message momentarily and then advances to UNIT only, if it was changed, otherwise press a to advance to UNIT Temperature Unit Submenu. 53 TEMPERATURE UNIT SUBMENU: Includes a byte in the data string to indicate whether reading is in Celsius or Fahrenheit. Press d 50) Display ...

Este manual também é adequado para os modelos :
Estação Meteorológica - CNI8 (1.2 mb)
Estação Meteorológica - CNI8C (1.2 mb)
Estação Meteorológica - CNI8DH (1.2 mb)
Estação Meteorológica - CNI16 (1.2 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias