EN61010-1 / CSA 22.2 No 1010.1 - 92 To offer a minimum of Basic Insulation only. Suitable for installation within Catagory II and III and Pollution Degree 2. SEE ELECTRICAL INSTALLATION P29 & P30 It is the responsibility of the installation engineer to ensure this equipment is installed as specified in this manual and is in compliance with appropriate wiring regulations. CONFIGURATION All functions are front selectable, it is the responsibility of the installing engineer to ensure that the configuration is safe. Use the program lock to protect critical functions from tampering. SAFETY INFORMATION ULTIMATE SAFETY ALARMS Do not use SP2 as the sole alarm where personal injury or damage may be caused by equipment failure. Safety A1 UNIT CONFIGURE INPUT SP1.D CONFIGURE OUTPUT SAFETY SETTINGS READ TECH PERFORMANCE DATA SP1.P HAND PL.1 PL.2 SP2.A SP2.B DISP HI.SC LO.SC INPT MANUAL ADJUSTMENTS FUNCTIONS MENU Range of Adjustment shown in red under description. If applicable, factory settings shown Setpoint 1 in bold. Process temperature (PV) or Function (green) Output * Note: Dual Relay and Dual SSd Output Options indicator Models CN9411 and CN9422 have their outputs Setpoint temperature (SP) or Option (orange) (green) pre-configured. (see page 22) Setpoint 2 Output indicator (red) ; LEV 3; LEV 2; ALLDisable program auto-exitAuto; StAY Disable -AL- alarm displayOff; on Display averagingdir; 1 to 32 (6)Derivative sensitivity0.1 to 1.0 x dEr.t (0.5) LEVL 4 LOCK PROG NO.AL DIS.S DER.S USER-PROTECTED SETTINGS SP1 output devicenonE; rlY; SSd*SP2 output devicenonE; SSd; rlY (read only) * Sensor burn-outuP.SC; dn.SC; 1u.2d; 1d.2uReverse outputs1r.2d; 1d.2d; 1r.2r; 1d.2rReverse O/P LEDs1n.2n; 1i.2n; 1n.2i; 1i.2iSpan adjustment0.0to 25% sensor f/sZero Adjustment0.0to 25%sensor full scaleSet MonitorOff; on Ar; hi; lo degRead Tune DataCtA; Ctb; Ct1; Ct2; Ct3;Ct4; oS1; uS; oS2Software versionConsult unit RESET nonE; ALL LEVL 3 Functions MenuA3 UER CALIBRATION RSET INSTRUMENT ADJUSTMENTS To enter or exit program mode: Press s t together for 3 seconds To scroll through functions: Press s or t To change levels or options: Press Q s together or Q t together To view setpoint: Press Q QUICK START ENTRY To increase setpoint: Press Q s together To decrease setpoint: Press Q t together LEVL 2 SP2 MODES RANGING SP2.D BURN REU.D REU.L SPAN ZERO CHEK to 100% read onlySP1 manual output %0 to 100% proportionalmode onlyLimit SP1 output %100to 0% Limit SP2 output %100to 0% Main SP2 modenonE; dV.hi; dV.Lo; bAnd; FS.hi; FS,Lo; CoolSecond SP2 modenonE; LtCH; hold; Lt.ho; Display resolutionor 0.1 degreeSet scale maximum0.0Sensor max tosensor full scaleSet scale minimum0.0Sensor min to sensorfull scaleSelect input sensornonE ; °C; °F; bAr;PSi; Ph; rh; SEt nLin 1 . KEY Q t OR Q s TOGETHER TO CHANGE LEVELS OR OPTIONS Autotune or ParkoFF; on; tunE; ParK; At.SpSP1 Prop band (gain)/hyst0.1 deg to 25% sensor f/s(10°C/18°F)Integral time (reset)Off; 0.1 to 60 min ( 5 min) Derivative time (rate)Off; 1 to 200 sec ( 25 sec) Derivative approach0.5 to 5.0 x bAnd (1.5) Cycle time or on/offOn.off; 0.1 to 81 sec(20 sec)Offset (manual reset)0to 50% x bAnd(In.t = off)Setpoint lock (SP1)Off; on Setpoint Ramp rate0to 9990 deg/hourRamp off/onOn; off; hold Soak timeOff; 0 to 1440 minAdjust SP2 setpoint+/– sensor full scale orfull scaleSP2 prop band/Gain/Hyst0.1 deg to 100% sensorf/s (2°C/3.6°F)SP2 Cycle on/offOn.off; 0.1 to 81 sec To reset an alarm or fault condition: Press s t together briefly Notes: If in difficulty by becoming “lost” in program mode, press s and t together for 3 seconds to return to display mode, check the INSTRUMENT ADJUSTMENTS above and try again. LEVL 1 TUNE BAND INT.T DER.T DAC CYC.T OFST SP.LK SPRR SPRN SOAK SET.2 BND.2 CYC.2 SP1 SETTINGS PROGRAMMER SETTINGS SP2 SETTINGS PROGRAM ENTRY . 9600: 19k2Data format18n1:18E1:18O1Tx/Rx activityOff; on When in program mode, after 60 seconds of key inactivity the display will revert to either INPT NONE Instrument address0to 255 Baud rate1200: 2400: 4800: Level C only visable KEY t s TO VIEW FUNCTIONS when COMMS Option fitted or, if the initial configuration has been completed, the measured value. Any settings already completed will be retained. LEVL C ADDR BAUD DATA COMMS SETTINGS DBUG 2 Press and hold Q Press ^ once 3 Select unit. and use the s or t buttons to scroll through the unit selection list until the correct unit is displayed. Release the buttons. The display will read selected unit e.g. The display will now read UNIT *C SPI.D NONE QUICK START 4 To enter initial configuration into controller memory Press and hold both s and t buttons for 3 seconds. The upper display will now alternate ParK and measured variable (temperature) (eg. 23 ) ParK is displayed because a setpoint has not yet been entered as shown by the lower display To display setpoint Press and hold . The displays will now read unit (eg. °C ) and 0 To enter setpoint Press and hold . and use s button to increase or t button to decrease th...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias