This device PRODUCT OVERVIEW REMOTE SENSOR BEFORE YOU BEGIN BATTERY INSTALLATION 4 6 7 8 displays and monitors temperature from up to three remote locations from the comfort of your home. In this package you will find: • One main unit (receiver) • One remote sensor (transmitter) TS03C• One User Manual LOW BATTERY WARNING GETTING STARTED CHECKING REMOTE AND INDOOR TEMPERATURES MAXIMUM AND MINIMUM READINGS 9 9 10 10 Please keep this manual handy as you use your newitem. It contains practical step-by-step instructions, as well as technical specifications and precautionsyou should know. PRODUCT OVERVIEW MAIN UNIT TRANSMISSION COLLISION 12 FEATURES PRECAUTIONS SPECIFICATIONS FCC STATEMENT DECLARATION OF CONFORMITY STANDARD WARRANTY INFORMATION 12 13 14 15 16 • Wireless transmission of the temperature from the remote sensor to the main unit from up to 100 feet (30 meters) away• Remote temperature display• Indoor temperature display• User-selectable temperature display in Celsius or Fahrenheit • Memory for the indoor and remote temperature readings• Wall mount or desktop option• Low battery indicator 2 3 4 FRONT VIEW A. TEMPERATURE INFORMATION IN A TWO – SECTION LCD DISPLAY B. CHANNEL BUTTON • Recalls the desired remote channel and indoor readings C. MEM BUTTON • Toggles between current, minimum and maximum readings of the indoor and remote temperatures • Clears the maximum and minimum temperature memory D. SEARCH BUTTON • Enforces the remote sensors signal search B D C SEARCH CHANNEL MEM 4 3 3 M H z C A B L E F R E E 4 FRONT VIEW A. TEMPERATURE INFORMATION IN A TWO – SECTION LCD DISPLAY B. CHANNEL BUTTON • Recalls the desired remote channel and indoor readings C. MEM BUTTON • Toggles between current, minimum and maximum readings of the indoor and remote temperatures • Clears the maximum and minimum temperature memory D. SEARCH BUTTON • Enforces the remote sensors signal search B D C SEARCH CHANNEL MEM 4 3 3 M H z C A B L E F R E E ° BUTTON • Selects temperature display in Celsius or Fahrenheit G. BATTERY COMPARTMENT • Accommodates 2 (two) UM-3 or AA 1.5V alkaline batteries. REAR VIEW E F G °C/°F 6 REMOTE SENSOR FEATURES • Remote temperature transmission to the main unit via 433 MHz signal• Case can be wall mounted using built-in hanger• 100 feet (30 meters) transmission range without interference• Selection of the temperature display in Celsius or Fahrenheit • Channel selection A. LED INDICATOR • Flashes once when the remote sensor transmits a reading to the main unit. • Flashes twice when battery power is low. B. BATTERY COMPARTMENT • Holds two AA-size batteries C. RESET • Resets all readings D. WALL-MOUNT RECESSED HOLE • Keeps the remote sensor on the wall E. °C/ °F SELECTOR • Selects the temperature display in Celsius or Fahrenheit F. CHANNEL SWITCH • Selects the desired channel THERMO – HYGRO SENSOR TM 1 D B ECA F SIZE AA / UM3SIZE AA / UM3 7 BEFORE YOU BEGIN • The remote sensor can be placed indoors or outdoors; the main unit must be placed indoors. • We recommend using alkaline batteries for the remote sensor and main unit when temperatures are above 32°F (0°C). We recommend using AA lithium batteries for the remote sensor when temperatures are below 32°F (0°C). • Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements). • Insert batteries before first use, matching the polarity in the battery compartment. • ALWAYS install batteries in the remote sensor before the main unit. • Press RESET after each battery change with a paper clip or similar tool. • During an initial setup, place the main unit as close as possible to the remote sensor. • After reception is established (the remote temperature will appear on the main unit’s display), position the remote sensor and the main unit within the effective transmission range of 100 feet (30 meters). NOTE: 1. Avoid pressing any buttons on the main unit before the remote temperature is displayed for about 2 minutes. 2. The effective operating range may be influenced by the surrounding building materials and how the receiver and transmitter are positioned. 3. Place the remote sensor so that it faces the main unit (receiver), minimizing obstructions such as doors, walls, and furniture. 4. Though the remote sensors are weather-resistant, they should be placed away from direct sunlight, rain or snow. 8 NOTE: When the temperature falls below freezing, thebatteries in the outdoor remote sensor may havereduced voltage supply and a shorter effective range. We recommend using lithium batteries at temperaturesof 32°F (0°C) and below. BATTERY INSTALLATION REMOTE SENSOR NOTE: Install the batteries; select the channel andtemperature in C° or F° before mounting the remote sensor. • Remove the screws from the battery compartment with a small Phillips screwdriver. • Set the channel. The switch is located in the battery compartment. Channel 1 is typically selected if only one remote sensor is being used. • Install 2 “AA” size alkaline bat...

Este manual também é adequado para os modelos :
Estação Meteorológica - TM004 (602.18 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias