Dimensions - Remote Control Box (RMB) 21 Form No. GRM-0707 TROUBLESHOOTING GUIDE WARNING WARNING To avoid any injury or damage the strip heater To avoid any injury or damage to the strip heater must only be serviced by qualified personnel. turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance. SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Unit is turned “ON” but there is no heat. No power to unit. Check circuit breaker and reset as necessary.
1 Form No. GRM-0707 IMPORTANT SAFETY INFORMATION CAUTIONS Standard and approved manufacturing oils will smoke up to 30 minutes during initial start-up. This is a temporary condition. To assure safe operation, operate unit without food product until smoke dissipates. Some exterior surfaces on the unit will get hot. Use caution when touching these areas to avoid injury. To prevent unit failure do not add a decorative soffit to hide a pass-through mounted Glo-Ray Strip Heater. Strip Heaters with in
(9 kg) Model GRAH-84•• Watts: 2050 Shipping Weight: 19 lbs. (9 kg) Voltage 120 208 240 100 200 220• 240• Voltage 120 208 240 100 200 220• 240• Amps 12.5 7.2 6.3 15.0 7.5 6.8 6.3 Amps 17.1 9.9 8.5 20.5 10.3 9.3 8.5 Model GRA-96• • Watts: 1725 Shipping Weight: 21 lbs. (10 kg) Model GRAH-96•• Watts: 2400 Shipping Weight: 21 lbs. (10 kg) Voltage 120 208 240 100 200 220• 240• Voltage 120 208 240 100 200 220• 240• Amps 14.4 8.3 7.2 17.3 8.6 7.8 7.2 Amps 18.3 11.5 10.0 24.0 12.0 10.9 10.0 Model GRA-108
Do not install dual stripheaters (GRA-XXD, GRAH-XXD, GRAL-XXD & GRAHL-XXD Series) above non-metallic surface. Install all non-dual strip heaters sothere is a minimum distance of 3" (76 mm) from a non-metallic wall or adjacent surface. To avoid any injury or damage to the unitwhen using chains for installation, the chains must have sufficient strength and be securely fastened, or the unit could becomeloose or fall. Do not place anything on top ofwarmers supported by chains. To avoid any injury or
If you’re unable to understand the contents of this manual, please bring it to the attention of your supervisor. Do not operate this equipment unless you have read and understood the contents of this manual. Este manual contiene importante informacion sobre seguridad concerniente al mantenimiento, uso y operacion de este producto. Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio dano. Si usted no puede entender el contenido de este manua
Dual units must always have a minimum spacing of 3" (76 mm) between heaters. T-Legs or C-Legs Do not mount units longer than 72" (1829 mm) on T-legs or C-legs. Over Steam Table When mounting over steam table, a remote control switch enclosure must be installed. CAUTION Unit is not moisture proof. Spacing of at least 16" (406 mm) is required for all units mounted over a steam table. Figure 10. Recommended Element Height for the GR, GRA, GRH, GRN, GRAH, GRAL, GRNH, and GRAHL in all lengths (exclud
Figure 18. Combustible Spacing Requirements A BC Pass Through Shelf Back Wall Counter Clearance Requirements for Non-Combustible Surroundings Corded Units with Built-In Switches Models (A) (B)† (C) GRA & GRAL 10" (254 mm) N/A 3" (76 mm) GRAH & GRAHL 11" (279 mm) N/A 3" (76 mm) Hardwired Units with Built-In Switches Models (A) (B)† (C) GRA & GRAL 8" (203 mm) N/A 1" (25 mm) GRAH & GRAHL with Infinite Heat Control Switch or Indicator Light 10" (254 mm) N/A 1" (25 mm) GRAH & GRAHL with On/Off Toggle
WARNING Units equipped with a cord and plug supplied by Hatco must be plugged into a properly grounded electrical outlet of the correct voltage, size and plug configuration. If the plug and receptacle do not match, contact a qualified electrician to determine the proper voltage and size and install the proper electrical outlet. NOTE: Units intended for fixed or permanent mounting cannot have a power cord attached and must be hard wired according to local and national electrical codes. Form No. G