Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Blue Rhino, Modelo SV-27

Fabricante : Blue Rhino
Arquivo Tamanho: 512.8 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. . . . . . . . . . . . . . . . . . . . Sold Separately 6.Wave Drawer™. . . . . . . . . . . . . . . . . . . . . . . . . . . 57-04-558 7.AA Battery . . . . . . . . . . . . . . . . . . . . . . . . . . Sold Separately 8.Battery Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . A57-04-555 9. Low Pressure Hose & Regulator Assembly . . . . . A57-04-561 10.Post . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A57-04-574 11.LP Gas Tank. . . . . . . . . . . . . . . . . . . . . . . . Sold Separately 12.Security Stake (4). . . . . . . . . . . . . . . . . . . . . . . A57-04-572 13.Base. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A57-04-577 14.Tank Cover - vinyl*. . . . . . . . . . . . . . . . . . . . . . . 57-04-304 * Not shown. 1.888.753.7137Page 5 Operation Placement The use and installation of this product must conform to local codes. In absence of local codes, use the National Fuel and Gas Code, ANSI Z223.1/NFPA 54, Storage and Handling of Liquified Petroleum Gases, ANSI/NFPA 58 or CSA B149.1, Natural Gas and Propane Installation Code. Properly positioning your SkeeterVac® device is important to maximizing performance. Since the SkeeterVac® device attracts mosquitoes it should be placed at least 10 feet from your living areas. Mosquitoes typically live in areas that are shady, wet and / or moist. Determine the primary mosquito habitat and place your SkeeterVac® device as close as possible to it. If you live in an area with consistent wind, place your SkeeterVac® device upwind from the primary mosquito habitat. CAUTION: Tipping danger. Use stakes to secure. Once you have selected the location, secure the SkeeterVac® device by placing a stake in each of the (4) stake holes. Maximum performance may require relocating your SkeeterVac® device from time to time. To move, remove stakes, place your foot on the cart base and tilt backward by holding the handle. Pull to the new location. Re-install stakes. FineTune®: Customizing the Lure Output The amount of octenol your SkeeterVac® device dispenses is important to maximizing performance. Some mosquito species are highly attracted to octenol while others are less attracted. This product contains an easy-to-use feature that allows you to customize the amount of octenol released to match the species in your environment. 1. Remove rain cover by turning counterclockwise 2. Remove foil seal from the Biting Insect Lure 3. Place lure back into holder with holes orienting upward 4. From the illustrations provided on the engine label, select the environment that best matches the area you are protecting 5. Position the ring so it points to your environment To Start 1. With the rain cover removed, turn gas ON at LP gas tank by slowly turning valve counterclockwise 2 full turns and be prepared IMMEDIATELY to follow step 2 2. IMMEDIATELY press and hold the red igniter button down until you hear a “POP” sound indicating ignition. Normally occurs within 20 seconds 3. The needle on the engine gauge should begin to move into the green zone, indicating ignition is complete CAUTION: If needle does not move within 20 seconds after “POP”, shut gas off at tank and wait 3 to 5 minutes before attempting to restart the engine 4. Replace the rain cover To Turn Off Turn gas OFF at tank by turning valve clockwise until it stops CAUTION: The gas supply must be turned off at the LP gas tank when this outdoor gas appliance is not in use. Model#CPSV002704 P PPage ageage 66 Maintenance Routine Service To ensure maximum performance and to lengthen the life of your SkeeterVac® device, perform these steps each time your tank is empty. This model will consume a standard 20# LP gas tank every 19-21 days. 1. Turn valve on propane LP gas tank OFF 2. Disconnect gas line from LP gas tank by turning knob counterclockwise 3. Remove empty tank replace with full LP gas tank 4. Reconnect gas line to LP gas tank by turning knob clockwise 5. Remove tank cover from empty LP gas tank and place on full LP gas tank 6. Remove WaveDrawer™, empty and slide back in place 7. Remove rain cover from top of SkeeterVac® 8. Remove used TacTrap™ and dispose of properly 9. Slide fresh TacTrap™ in place and remove protective paper 10. *Remove used lure (if necessary) and properly dispose 11. Remove fresh lure from package (if necessary). Dispose of packaging properly 12. Place fresh lure into well (if necessary) 13. Set FineTune® ring to desired setting 14. Check engine and gas lines for any sign of damage or missing parts. Repair any problems before attempting to start 15. To start - follow instructions “To Start” on page 6 16. Once started, securely attach the rain cover 17. Wash hands with soap and water *Lure lasts 60 days Replacing Igniter Battery If you do not hear a clicking sound when the igniter button is depressed, the battery may have lost its charge. Replace battery as follows: • Open battery compartment by turning cap on bottom of engine counterclockwise • Remove used battery and...

Este manual também é adequado para os modelos :
Outros acessórios para a casa - CPSV002704 (512.8 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias