Instruções de Operação Chicago Electric, Modelo 96035

Fabricante : Chicago Electric
Arquivo Tamanho: 2.26 mb
Arquivo Nome : 96035.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Physically check that the chisel is secure before operating. The chisel will have approximately 1-3/4” of play, but should not come out when pulled. Operating Instructions Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Work Piece and Work Area Set Up Designate a work area that is clean and 1. well-lit. The work area must not allow access by children or pets to prevent distraction and injury. Route the power cord along a safe 2. route to reach the work area without creating a tripping hazard or exposing the power cord to possible damage. The power cord must reach the work area with enough extra length to allow free movement while working. Secure loose work pieces using a vise 3. or clamps (not included) to prevent movement while working. There must not be objects, such as utility 4. lines, nearby that will present a hazard while working. General Operation To prevent serious injury: Wear ANSI-approved safety goggles, ear protection, steel-toe boots, and dust mask during use. Keep feet clear of Breaker Hammer. Keep children and animals well clear of the work area. Use this tool only with a 20 AMP Circuit Breaker. This Breaker Hammer may have decreased performance for a brief period at the beginning of each use. This warm- up period lasts approximately 3-5 minutes. This happens because the grease inside the tool may be somewhat thick, preventing the tool from operating at full efficiency while the motor is cold. This is perfectly normal and does not indicate a problem. To help reduce this effect, we recommend storing this equipment in temperatures no lower than 50- 60° F. Only use sharp tipped chisels. Dull tipped chisels can cause unneces- sary chisel movement, resulting in tool wear and possible injury. Figure 3Before each use, check the Chisel for dullness, cracks or other damage: Never use a dull or damaged Chisel. See Figure 3. Clearly mark the work area.1. Plug in the Breaker Hammer.2. Place the Chisel on the block you will be 3. breaking. NOTE: Carbon Brushes (51) will wear during use. The Breaker Hammer will cease functioning if the Brushes are worn. This does NOT mean Breaker Hammer is malfunctioning or broken, only that the worn Brushes will need to be replaced with the included Brushes by a qualified technician. Grasp the handles firmly with both hands 4. and depress the Trigger (86). As you break the block into big chunks, 5. release the Trigger (86) and move to other large pieces until all of the larger pieces are broken. Do not try to break up smaller pieces with this tool as it is too powerful and aggressive to control on small pieces. When you are finished, release the 6. Trigger (86) and unplug the cord. Clean, then store indoors out of 7. children’s reach. Important - Replacing Carbon Brushes The Breaker Hammer will cease operation once the carbon brushes are worn. Check Carbon Brushes (51) after every hundred (100) hours of regular use. If brush change is necessary, it must be done by a qualified service technician. Figure 4Screws (1) Cover (2) 1. Set the Breaker Hammer down on a work bench with the spline axles closer to the top. Use a 5mm Hex Wrench (not included) to loosen the four Screws (1) fastening Cover in place. See Figure 4. Cover (2) Figure 5 2. Slide Cover off top of Breaker Hammer. See Figure 5. REV 10e Figure 3Nut (91) Left Handle (92) Figure 6 3. Use a Wrench to loosen the Nut (91) holding the Left Handle (92) in place. See Figure 6. Figure 7Spline Axle (27) Left Handle (92) 4. CAUTION: When removing Left Handle, do not pull too far from Spline Axle (27) Only wiggle loose until partially off. See Figure 7. Figure 8Gearbox (23) Screws (25) 5. Remove the four Screws (25) from the side of the Gearbox 23. See Figure 8. Figure 9Wire Board (50) Screw (52) 6. Slide Gearbox open so that Wire Board (50) is visible. Use screwdriver (not included) to loosen Screw (52) from Wire Fixing Board. See Figure 9. Figure 10Carbon Brush (52) Carbon Brush Holder (53) Wire Fixing Board (50) Carbon Brush Holder Spring 7. Remove the Wire Board from the top of the Carbon Brush Holder (53). Then use tip of flat-edge screwdriver (not included) to carefully pop the Holder’s spring off the top of the Carbon Brush (51). See Figure 10. CAUTION! 8. The spring must be clear of the Holder lip to remove Carbon Brush. Use the screwdriver to slide the Carbon 9. Brush from the Holder. Then replace with new Carbon Brush. Snap spring back into place and use 10. Screw to replace Wire Board. To better access the second Carbon 11. Brush, turn the Breaker Hammer over. Repeat Steps 7 to 10 to replace second Carbon Brush. Figure 11Gearbox TabHousing Slot 12. Once both Carbon Brushes have been replaced, slide Gearbox shut. CAUTION: When closing Gearbox, make sure tab along rim of Gearbox aligns with the slot in the housing. See Figure 11. Use the four screws to fasten the 13. Gearbox back into place. Then ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias