Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP Virtual Connect Enterprise Manager BLc3000 24x7 Support No Media 1-encl Lic

Fabricante : HP
Arquivo Tamanho: 61.5 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso



existing server profiles from the original VC Domain, are preserved after the creation of the new VC Domain during the process of
replacing the primary or backup VC modules.
These steps require that you have a VC Domain Group that will temporarily hold the server profiles while replacing the VC
modules.
1. Click the Server Profile tab from the VCEM home page.
2. Select VC Domain in the first filter and select the VC Domain name (with the primary or backup VC modules to be replaced) in the
second filter.
3. For the server profiles in the selected VC domain:
IMPORTANT:
Use the VCEMCLI, to export the server profiles to a CSV file as a record of the server profile names, bay assignments and profile
connections. For more information on the export command, see the HP Insight Management Virtual Connect Enterprise Manager
Command Line Interface User Guide at http:/ www.hp.com/go/insightsoftware/docs.
a. Ensure that the server is powered off.
b. Click Edit and unassign all existing connections. Wait for the job to complete successfully.
c. Click Unassign. Wait for the job to complete successfully.
d. Click Move if the current VC Domain Group that contains the VC Domain with the primary or backup VC modules that need to
be replaced has no other members, select another VC Domain Group that with a compatible minimum configuration and
leave the server profile unassigned. Wait for the job to complete successfully. See the HP Virtual Connect Enterprise
Manager User Guide at http:/ www.hp.com/go/insightsoftware/docs for more details regarding moving a server profile to a
dif erent VC Domain Group.
These server profiles remain unassigned in the selected VC Domain Group in VCEM while upgrading the VC Domain modules. The
server profiles can be assigned back to the original VC Domain after the VC module replacement is complete. To complete the VC
module replacement:
1. Click the VC Domains tab from the home page.
2. Select the VC Domain with the VC Ethernet modules to be replaced.
3. Click Remove from VC Domain Group. Wait for the job to complete successfully.
4. Follow the steps described in the HP Virtual Connect for c-Class BladeSystem User Guide at
ht p:/ h18004.www1.hp.com/products/blades/components/c-class-tech-installing.html for your specific replacement scenario.
CAUTION:
If a VC firmware update is required for the scenarios below then make sure that you select a VC firmware version supported by the
VCEM version. See the HP Virtual Connect Enterprise Manager User Guide at http:/ www.hp.com/go/insightsoftware/docs for more
details regarding supported VC firmware versions.
IMPORTANT:
If you already have a VC Domain Group that meets minimum requirements to add the VC Domain with replaced VC modules, you can
omit the VC Domain recreation steps described in the HP Virtual Connect for c-Class BladeSystem User Guide at
ht p:/ h18004.www1.hp.com/products/blades/components/c-class-tech-installing.html.
IMPORTANT:
Omit the server profile and connections reassignment steps described in the HP Virtual Connect for c-Class BladeSystem User Guide.
Instead, use VCEM to reassign the server profiles, then reassign the networks and fabrics to the connections using the information in the
CSV export created earlier in the process as a reference.

The following are examples of the current replacement scenarios:

• Replacing a VC Ethernet module with an HP VC Flex-10 module or HP FlexFabric module in a horizontally adjacent bay pair
hosting VC Manager (the horizontal bays housing primary and/or backup modules)
• Replacing a VC Ethernet module with an HP VC Flex-10 module or HP FlexFabric module in a horizontally adjacent bay pair not
hosting VC Manager
• Replacing an HP VC Flex-10 module or HP FlexFabric module with a VC Ethernet module in a horizontally adjacent bay pair
hosting VC Manager (the horizontal bays housing primary and/or backup modules)
• Replacing an HP VC Flex-10 module or HP FlexFabric module with a VC Ethernet module in a horizontally adjacent bay pair not
hosting VC Manager


3


...

Este manual também é adequado para os modelos :