Facilidade de uso


InForm OS Version 2.2.4
Release 2.2.4 MU6 Release Notes
Bug ID
Item
Description
43577
A loss of
Occasionally, (due to a loop disruption while the drive is
communications on
communicating ESI data), the ESI drive and FPGA could get
the ESI channel to
out of sync. Due to this out of sync condition, the system
individual drive ports
manager was no longer able to use that channel to
causes the DC2/DC4
communicate with the cage.
cage CPU to become
unresponsive even
The cage firmware now resets the FPGA's ESI channel at an
though the drives
appropriate point between every transaction.
remain on loop and
available.
43595
Controller shutdown
A bug in InForm OS software could leak memory slowly on
due to memory leak.
E/S class InServs when the inter-node transport was under
stress. It could take many days for the free memory size to
fall into the critical level that triggered a warning.
The buffer is now handled properly.
43997
WMware ESX4.0 iSCSI
A bug in the InForm OS software caused the SCSI2
certification test "dual
reservation on a LUN held by an iSCSI initiator to not be
initiator reserve and
cleared when a LUN reset command was sent to the target.
reset LUN would fail".
45531
Resource leak in iSCSI
If the initiator driver on an iSCSI host is very slow to respond
driver results in all I/O
to a pending request for data from the iSCSI firmware in the
stopping on an iSCSI
InForm iSCSI adapter, the InForm iSCSI driver could leak a
port.
resource associated with that I/O. If all resources are
exhausted over time, the iSCSI port stopped processing all I/
O and needed to be reset to recover the resources.
45955
SCSI command not
The iSCSI driver in InForm OS was not aborting the correct
aborted when host
command when the host sent an abort because the driver
sends an abort.
was not using the correct ITT value from the abort iSCSI
PDU.