Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP 3PAR InForm Software

Fabricante : HP
Arquivo Tamanho: 90.51 kb
Arquivo Nome :
Língua de Ensino: ennn
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


These release notes describe the modifications and known issues for Patch 13. The application of this
patch is intended for HP 3PAR InForm OS 3.1.1.342. Only an authorized HP Service provider should
perform this maintenance procedure.
1.1 Supported platforms
The HP 3PAR Configuration Matrix for InForm OS 3.1.1 contains information about supported hardware
and software platforms. For additional information, go to the Single Point of Connectivity Knowledge
for HP Storage Products (SPOCK) Web site at http://spock.corp.hp.com/index.aspx.
1.2 Verifying the patch installation
The installation of Patch 13 can be verified from an Interactive CLI session. Issue the CLI command
showversion -a -b to verify that Patch 13 is listed.
cli% showversion -a -b
Release version 3.1.1.342 (MU1)
Patches: P13
Component Name Version
CLI Server 3.1.1.342 (MU1)
CLI Client 3.1.1.342 (MU1)
System Manager 3.1.1.362 (P13)
Kernel 3.1.1.342 (MU1)
TPD Kernel Code 3.1.1.342 (MU1)
TPD Kernel Patch 3.1.1.362 (P13)
...
NOTE:
This patch is not revertible after installation.
1.3 Components
Component
Version
System Manager
P13
NEMOE
3.47
1.4 Modifications to the InForm OS
The following items have been addressed in this release.
Issue number Item
Description
69127
Import of a snapshot in ESX
When an ATS request occurs on a page with pending DCOW, the ATS
fails with invalid meta data
handling path does not resolve the pending DCOW.
when VAAI ATS is enabled.
70119
Enhancement for Sysmgr
This prevents the sysmgr termination when a CPG has no space to grow when
Termination when using
region mover is called via movereg. Most customers would use this mcall
region mover.
with Adaptive Optimization.
70195
Change recovery mechanism Changed the recovery mechanism from resetting the controller node to
for firmware error from node
resetting the Host Bus Adapter (HBA) port for a rarely seen HBA firmware
reboot to port reset.
error.
70712
Bi-weekly automatic BBU test
The system has been enhanced to test the BBU appropriately so that the BBU
by Sysmgr turns on but never is not completely drained
turns off.
The enhancement in NEMOE FW (3.47) prevents BBU from discharging if
minimal condition (at least one power supply has AC ok) is met.
1.1 Supported platforms
3


...

Este manual também é adequado para os modelos :
dados de dispositivos de processamento - HP 3PAR Operating System Software Suite (90.51 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias