Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP Cluster Software

Fabricante : HP
Arquivo Tamanho: 73.95 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso



Languages
International English
Enhancements
• Support for Hyper-V Live Migration
• Software updates through Software Update Manager (SUM)
You must register in order to perform software updates using SUM.
To register for SUM access:
1.
Open the HP IT Resource Center (ITRC) website: http://www.itrc.hp.com.
2.
Click Register. Follow the on-screen instructions to create an ITRC User ID.
3.
Link your support agreement(s) to your ITRC User ID. For instructions, see the following website:
http://www.itrc.hp.com/service/entitlements/linkSupportAgreement.do.
You will need the System Handle or Service Agreement ID (SAID), as identified in your support
agreement.
To access SUM, click the Software Update Manager link on the ITRC website.
TIP:
You can configure SUM to notify you when software updates are available.
Fixes
N/A
Prerequisites
• Windows Server 2008 only: In certain situations, resources do not follow the Preferred Owners
List order during failover. See the Microsoft Knowledge Base article KB950181 for more informa-
tion.
• A physical disk resource may unexpectedly fail or go offline when the IsAlive function is run on a
Windows Server 2008 cluster node. See the Microsoft Knowledge Base article KB953652 for
more information.
• Immediately after installing XP Cluster Extension, bringing a resource online might fail with the
error Create process to execute command "horcmstart instance" failed. This
error occurs because the XP Raid Manager environment path variable value is not reflected for
the XP Cluster Extension resource. If you experience this problem, restart the cluster service on the
affected cluster node to resolve the issue. After you restart the cluster service, this error message
will not appear again.
• In a Server Core or Hyper-V Server environment, after the installation of XP Cluster Extension, the
XP RAID Manager-related path environment variable value is not updated correctly to XP Cluster
Extension. To work around this issue, re-login to the Windows session on the cluster nodes or reboot
the cluster nodes.
4


...

Este manual também é adequado para os modelos :
dados de dispositivos de processamento - HP LeftHand P4000 Virtual SAN Appliance Software for VMware ESX Server LTU (73.95 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias