Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Clarke, Modelo BEXT 150H

Fabricante : Clarke
Arquivo Tamanho: 464.35 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


When used with a floor tool, the machine applies cleaning solution to the carpet and removes the dirty solution and soil from the carpet. • The extractor has controls to start the pump for the solution and the motor for the vacuum. The floor tools have controls to release the solution. • The extractor has a bypass pump. The pump runs when switched on, bypassing solution internally to keep pressure even.The extractor starts when the solution lever on the floor tool is activated. SPECIFICATIONS Bext 100 Bext 100H Bext 100H Detailer Bext 150H Bext 150H Detailer Bext 300HPart Number 04156A 04157A / 04158A 04147A / 04152A 04148A Solution Tank 9 gallon rotationally molded 13 gallon rotationally molded Solutin Pump 100 psi demand pump 150 psi demand pump 300 psi demand pump Vacuum Motor 5.7", 3 stage (2) - 5.7" 2-stage 7.2" 3-stage Waterlift 140" 150" 140" Easy Circuit Locator N/A Standard Standard Standard On-board Heater N/A Standard Standard Standard Wand Double bend twin nozzle polished stainless steel Power Cable 25 ft. 12-3 hosp. grade plug (2) 25 ft. 12-3 hosp. grade plugWheels (2) 8" non-marking & (2) 3" casters (2) 10" non-marking & (2) 2" casters Hose 15 ft. crushproof vacuum and high pressure solution line Low Moisture System Standard Float Shut-Off Standard Weight 69 lbs. 75 lbs. 90 lbs. 119 lbs. Warranty Product Lifetime (10 years) on tank and mainframe; 1 year Parts and labor NOTE: When using the extractor to clean carpets, follow this procedure: 1. Do not walk on freshly cleaned carpets for at least four hours or until the carpet is dry to touch. 2. Do not remove aluminum or plastic pieces that have been placed under the legs of furniture untilthe carpet is dry. 3. Do not allow children or pets to crawl or walk around on the damp carpet. 4. Vacuum right after the carpet is dry and then vacuum the carpet once a week as needed. Page 6 Clarke® BEXT® -100, 100H 150H, 300HV Operator's Manual CONTROLS and MACHINE FEATURES 1G 1H 1B 1A 1C 1F 1E 1D CONTROLS and MACHINE FEATURES 1G 1H 1B 1A 1C 1F 1E 1D Figure 1 Figure 1 1I 1J Figure 2 The Vacuum Motor Switches See Figure 1-A The vacuum motor switches are located on the top of the machine. The Switch To Activate The Pump See Figure 1-B The switch to start/stop the pump motor is on the top of the machine. Press the lever on the floor tool to start the solution flow. Release the lever on the floor tool to stop the solution flow. NOTE: While the BEXT-150 machine is in operation, the pump will shut-off automatically when it reaches full pressure. The pump will automatically turn on when the pressure decreases. The Float Shut-Off -See Figure 1C The float shut-off is in the recovery tank. When the liquid raises the float, the air stops moving through the machine. NOTE: To avoid vacuum motor damage, always inspect the float filter and ball. Verify ball travels easily prior to use of unit. See Figure 2 The Vacuum Hose Connector See figure 1D The vacuum hose connector is on the front of the unit. The Solution Hose Connector See Figure 1E The solution hose connector is on the lower part of the extractor, below the vacuum hose connector. The Recovery Tank See Figure 1F The recovery tank is in the top of the machine. The Solution Tank See Figure 1G The solution tank is in the top of the machine next to the recovery tank. Electric Circuit Locator See Figure 1H This unique, patented "smart system", operated by a solid state circuit, will inform the operator when the two cords are plugged into separate circuits by illuminating the "Locator" indicator light. This helps prevent tripping circuit breakers. NOTE: Ground plug on the cord is required to allow circuit locator to operate correctly. The system will not function without proper ground. The Machine Power Cord (Red "H") See Figure 1I This cord powers all machine functions exceptthe heater. The Heater Power Cord See Figure 1J This cord powers heater only. Page 12 Clarke® BEXT® -100, 100H 150H, 300HV Operator's Manual HOW TO PREPARE THE MACHINE FOR OPERATION HOW TO PREPARE THE MACHINE FOR OPERATION Figure 3A Figure 3B To prepare the machine for operation, follow this procedure: 1. Connect the vacuum hose to the hose connector on the extractor and to the end of the vacuum tube on the floor tool. See Figure 1 D, E 2. Connect the solution hose to the extractor and the floor tool. To fasten the quick disconnect fitting, slide the knurled collar on the female couplingaway from the opening. Push the male couplinginto the female coupling. See figure 3 A & B WARNING: Do not use water that is hotter than 120°F (48°C). 3. Before moving the extractor onto the carpet, putclean hot water into the solution tank. 4. Add a cleaning chemical, such as Clarkare® Extractor Concentrate, to the hot water. For the correct amount, follow the directions shown on the container. Set-Up WARNING: We recommend that you use liquidcleaning chemicals. Powder can damage machine. Powders can cause build-up in the lines, heater, pump, quick disconnects, etc.,...

Este manual também é adequado para os modelos :
Aspiradores - BEXT 100 (464.35 kb)
Aspiradores - BEXT 300HV (464.35 kb)
Aspiradores - BEXT 100H (464.35 kb)
Aspiradores - BEXT 120V (464.35 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias