Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Clarke, Modelo BEXT 300HV

Fabricante : Clarke
Arquivo Tamanho: 464.35 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Switches are on when illuminated. CARPET / UPHOLSTERY SWITCH ( 3 ): This switch is also powered by cord #1. The carpet setting (down position) is highpressure (approximately 300 psi). The upholstery setting (upposition) is low pressure (approximately 75 psi). NOTE: Switch does not illuminate. HEAT SWITCH ( 4): Turning on this switch (switch illuminateswhen on) turns the heater on. GREEN CIRCUIT LOCATOR LIGHT ( 5 ): When this light is illuminated, it confirms that the machine is on two separate circuits. See previous page for additional information on the circuitlocator. HEAT LIGHT MODE ( 6 ) : The light will only illuminate when theheater uis heating and will turn off when it reaches operating temperature. Page 18 Clarke® BEXT® -100, 100H 150H, 300HV Operator's Manual INSTRUCTIONS FOR CONNECTION TO THE POWER SUPPLY AND ELECTRICAL GROUND -120 V CAUTION: This machine will operate only on an AC frequency and on the specified electrical voltage shown on the nameplate. Make sure you have the correct frequency and voltage before connecting the power cord to an outlet. This machine must be connected to an electrically grounded Plate Screw Outlet must be connected to the electrical ground Ground PinPlate Screw Outlet must be connected to the electrical ground Ground Pin Tornillo de la placa Terminal de tierra El tomacorriente debe estar conectado al borne de puesta a tierra Figura 7 Figure 7 Figure 7 circuit in order to protect the operator from electric shock. This machine has an approved power cord with three conductors as well as a plug with three terminals. Connect the plug to a three holed receptacle. For maximum protection against electric shock, use a circuit that is protected by a ground fault circuit interrupter. This machine uses a 120 volt AC 50/60 cycle electrical circuit. Make sure you have the correct frequency and voltage before connecting the power cord to an outlet. The machine has a plug as shown in Figure 7. If a receptacle connected to the electrical ground as shown in Figure 7 is not available, contact an electrical contractor. Do not use an adapter. WARNING: To prevent possible electric shock, protect the machine from rain. Keep the machine in a dry building. WARNING: To prevent possible electric shock, always use a 3-wire electrical system connected to the electrical ground. For maximum protection against electrical shock, use a circuit that is protected by a ground fault circuit interrupter. Consult your electrical contractor. WARNING: Do not cut, remove, or break the ground pin. If the outlet does not fit the plug, consult your electrical contractor. WARNING: If the cords or plugs are worn or damaged in any way, have them replaced by an authorized service person. Extension Cords Use only an approved extension cord with three conductors, a plug with three terminals and a three-holed connector body. This machine has a power cord with a wire size of 12 AWG. (AWG stands for American Wire Gauge). CAUTION: If you use an extension cord, use one that has a minimum wire size of 12 AWG. Be sure your extension cord is no longer than 50 ft. Do not join two extension cords. Borne male de la prise Fiche de terre Le receptacle doit etre connecte a la masse Page 20 Clarke® BEXT® -100, 100H 150H, 300HV Operator's Manual MACHINE OPERATING INSTRUCTIONS MACHINE OPERATING INSTRUCTIONS Area 1 See figure 8 Superficie 1. Vea la Figura 8 Zone 1 Voir figure 8 Figure 8A Figure 8B Vacuum only, after cleaning each area for maximum water removal Aspiration seulement, apres nettoyage de chaque zone pour une elimination maximum de l'eau Para eliminar la mayor cantidad de agua posible solo realice la aspiracion despues de limpiar cada superficie How to Clean an Area of Carpet See Figure 8A WARNING: Do not use water that is hotter than 120°F (48°C). To clean an area of carpet, follow this procedure: 1. Start the pump for the solution and the motor for the vacuum on the extractor. 2. Begin at the right-hand corner of the carpet. 3. Hold the floor tool at the angle that gives the best vacuum seal between the tool and the carpet. 4. Apply pressure to the lever for solution release. Pull the tool toward you at a slow, steady speed. To remove as much solution as possible, release the lever before you stop moving backward. Push tool away over the same area while moving tool to next position. (Repeat process) 5. To clean the edge of a room, move the tool along the baseboard until the edge of all the carpet is cleaned. 6. To clean a small area of carpet, clean the carpet in sections three feet square. As you make more passes, repeat one inch of the area already cleaned. 7. To remove more liquid from the carpet, make passes over the area already cleaned, but do not apply pressure to the lever for the solution. How To Clean A Larger Area Of Carpet See Fig. 8B To clean a larger area of carpet, follow this procedure: 1. Begin at the right-hand corner of the carpet. 2. Make a pass halfway along the edge of the carpet. Pull the tool back...

Este manual também é adequado para os modelos :
Aspiradores - BEXT 100 (464.35 kb)
Aspiradores - BEXT 150H (464.35 kb)
Aspiradores - BEXT 100H (464.35 kb)
Aspiradores - BEXT 120V (464.35 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias