|
Facilidade de uso
- The tenths digit will be blinking, when this value is entered, the hundredths place will blink. After the hundredths place is entered the value is automatically entered. Due to the nature of the double cut cycle, some combinations of strip lengths and slug lengths cannot be performed. • Press Count/Clear on your key pad • Self Check - Press enter and hold to display batch number and selected cycle mode. Note: Slug length too long for strip length - This message appears on the screen when the cycle is triggered. The cycle will not run. When the system receives a trigger, an audible tone will beep and the above message will continue to be displayed on the screen for two seconds. The system then returns to the ready mode. In order to get a Double Cut cycle to run, one must increase the strip length or decrease the slug length until an acceptable combination is reached. Min. 1.25 strip length. • Insert wire for double cut cycle mode • Remove wire when cycle is complete. STP Operation continued Slug Removal SINGLE CYCLE The STP can be used to remove the slug without applying heat to the blades, if the insulation has already been severed. This is accomplished by pressing “0” when the unit is in the “READY MODE”. The next cycle will run with zero heat and act only as a slug removal machine. When this cycle is completed, the STP returns to the previous settings. REPEATING CYCLE When the heat value is set to “0” percent the unit will perform the slug removal cycle when activated. The unit remains in this mode until a non zero heat value is selected. BATCH ENTER Set Mode • Press PROGRAM/HIGH • Enter in the 3-digit security code NOTE: All units are factory preset to a 3-digit security code of “111”. To make any changes in the Program Mode the security code must be entered. • Press 1 - Test 2 - Set 3 - Mode Clear_Esc • Select [2] - Set When CLEAR is pressed during any branch of the program mode, the display returns to the beginning and no changes are made. PRGM. HIGH Press ENTER IN 3-DIGIT SECURITY CODE Press PRESS FOR CHOICE 1-TEST 2-SET CLR-ESC Enter Security Code 2 Key 1-Set strip length increment 2-Set security code 3-Units 4-Lock out 5-Count 1-Blade home 2-Grip home sensor3-Grip back sensor4-Trigger sensor5-Wire out sensor 6-Sensor test off Up Up Up Dow n Dow n Dow n Dow n Up 1-Full cycle2-Half cycle 3-Step manually -Clockwise -Counter clockwise Up Up Up Up Dow n Dow n Down Up Up Up Dow n Dow n Dow n Dow n -Back -Forward Program 1-Test 2-Set Main Menu 1-Warning on 2-Warning off3-Set limit 4-Clear count 2- Lock off 1- Lock on 2- Metric1- English 0 Key 1 Key 2 Key 3 Key 4 Key 6 Key 5 Key 7 Key 3 Key 4 Key 5 Key 1 Key 0-Test the sensors 1-Air blast 2-Pull cylinder 3-Chute 6-Front gri p 5-Rear grip 7-Wire gate 8-Blade rotation 10-Beeper 9-Strip position 11-Blade heat 4-Trigger 8 Key 9 Key 3 Key This flow chart shows the sequence of functions in the program mode indicating the keys to press and the display screens with available options. The test mode shows the options for testing sensors and solenoids. STP Operation continued Set Mode 1 INCR 2 CODE 3 UNIT 4 LOCK OUT 5 COUNT 1 — STRIP LENGTH INCREMENT SET STRIPLENGTH INCREMENT 0.00 IN SET STRIPLENGTH INCREMENT 0 MM This allows programming the strip length in increments by using the arrow keys to increase or decrease the length appearing on the display. ENGLISH LENGTH MODE - (0.01 in. to 0.99 in.) The tenths position begins blinking. After the tenths digit is entered, the hundredth position blinks. After the hundredth digit is entered the unit will automatically return to ready mode. METRIC LENGTH MODE - (1 mm to 99 mm) Enter the increment length, 1mm to 9 mm, and press ENTER. Increment lengths of 10 mm to 99 mm are automatically entered after being typed in. 2 — SECURITY CODE ENTER NEW CODE NEW CODE Enter the new 3-digit code. CLEAR can be pressed any time during this process and the current 3-digit code is restored. 3 — SELECT UNITS (IN/MM) SELECT 1 ENGLISH 2 METRIC This allows the selection of English or metric units. Press [1] for English or [2] for metric. 4 — KEYBOARD LOCKOUT LOCK OUT 1 LOCK ON 2 LOCK OFF This allows locking out everything on the keyboard except for calling up batches and adjusting the strip length. Press [1] for lock on or [2] for lock off. 5 — COUNTS There is an 8-digit counter that starts at 0 when the machine is built and counts every cycle. This counter is nonresettable. There is a 6-digit counter that counts every cycle and is resettable. [1] (Warning On) activates the “SERVICE MACHINE” warning that appears at the end of a cycle if the resettable count is equal to or above the limit that has been set. 1 WARN ON 2 WARN OFF 3 SET LIM 4 CLR CNT [2] (Warning Off) disables the “SERVICE MACHINE” warning. [3] (Set Service Limit) allows setting the limit of cycles to when the warning should go off (from 0 to 999999). This also is a reminder to reset the count. [4] (Clear Service Count) resets the count. When the service count is reached a warning ...
Este manual também é adequado para os modelos :receptor e amplificador - 45-935 (915.59 kb)