5. A union should be installed between the check valve and the pump so the pump can be removed with least disturbance of the piping. 6. CSE50T models are supplied with a detachable tether switch with a piggyback plug (see figure 3A). The length of the tether (distance of cord from float to clamp) should not be set shorter than 3-1/4 inches and should not be used in a basin smaller than 14 inches in diameter. If using a differential other than the factory setting, be sure when the pump shuts off at least 4 inches of fluid is left in the basin so the impeller remains submerged. 7. When a tether switch is used, rigid discharge pipe is required. If the pump is allowed to move, the tether switch could be restricted by the basin wall, preventing the pump from operating. Before removing pump from basin for service, always disconnect electrical power to pump and control switch. For any work on pump or switch, ALWAYS unplug the power cord. Do not just turn off circuit breaker or unscrew fuse. Check valve 45o Vent Inlet Gasket 1/2" Min. Clearance Basin Figure 3A - Prefabricated Basins Main waste line to sewer or septic tank Upper level drainage Three prong grounded outlet equipped with a ground fault interruptor 2 inch Discharge pipe Sewage pump passes 2 inch dia. solids Cleanout Vent pipe 2 inch Gate Valve Union 2 inch Check Valve 45o Elbow Laundry tubs WasherDryer Floor drain Washer drain Lavatory Toilet Shower Flange Figure 2 - Typical Installation 3 Operating Instructions and Parts Manual Installation (Continued) 8. CSECAP40 and CSECAP50 models are supplied with an “Switch- Genius” capacative water sensor (see figure 3B). Position the pump in the basin so that the “Switch- Genius” water sensor is 180° away from the basin inlet. Make certain the incoming water stream does not hit the “Switch-Genius” water sensor surface. Before removing pump from basin for service, always disconnect electrical power to pump and control switch. For any work on pump or switch, ALWAYS unplug the power cord. Do not just turn off circuit breaker or unscrew fuse. Check valve 45o Vent Gasket Inlet “Switch- Genius” surface * Basin * Orient the pump so that the “Switch- Genius” switch surface is 180° away from the inlet. Make sure the incoming water stream does not hit the “Switch- Genius” surface. Figure 3B - Prefabricated Basins Maintenance Make certain that the pump is unplugged before attempting to service or remove any component. This pump is assembled in the factory using special equipment; therefore only authorized service dealers or qualified electricians should attempt to repair this unit. Improper repair can cause an electrical shock hazard. The pump contains oil that may be under pressure because of heat. Let the pump cool for a minimum of two hours before servicing this unit. 1. Disassembly of the motor prior to expiration of warranty will void the warranty. It might also cause internal leakage and damage to the unit. If repairs are required, return the pump to the dealer from whom it was purchased or call 1-800-2370987. If motor is ever disassembled the o-rings must be replaced. Care must be taken to ensure that all seals do not leak. 2. After the basin cover is removed and necessary discharge piping disconnected, lift pump from basin. 3. Pump should be checked on a regular basis for proper operation. If anything has changed since unit was new, the unit should be removed and repaired or replaced. Only qualified electricians or service people should attempt to repair this unit. Improper repair and/or assembly can cause an electrical shock hazard. 4. Place the pump in a suitable area where it can be cleaned thoroughly. Remove all scale and deposits on pump. 5. Submerge the complete pump in a disinfectant solution (10% chlorine bleach solution) for at least one hour before handling the pump. 6. Clean all dirt and deposits from the pump float. Make sure float moves freely after cleaning (CSE50T). 7. Clean all dirt and deposits away from pump inlet and volute. 8. Clean “Switch-Genius” water sensor surface (models CSECAP40 and CSECAP50). This pump contains dielectric motor oil for lubrication and motor heat transfer. This oil can be harmful to the environment. Check state environmental laws before disposing of this oil. This oil can be harmful to aquatic life so consideration should be exercised in the application of this pump. 4 CSECAP40, CSECAP50, CSE50T Troubleshooting Chart - CSE50T Symptom Possible Cause(s) Corrective Action Pump will not start or 1. Water level too low 1. Pump switch will not turn on unless water covers top of run 2. Blown fuse or tripped circuit breaker pump 2. If blown, replace with proper sized fuse or reset breaker 3. Low line voltage 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact 4. Defective motor 5. Defective float switch 6. Impeller (pump filled with debris) 7. Tangled switch 8. Insufficient liquid lev...

Este manual também é adequado para os modelos :
Canalização - 330502-001 (2.18 mb)
Canalização - CSE50T (2.18 mb)
Canalização - CSECAP50 (2.18 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias