Instruções de Operação Wayne, Modelo 330502-001

Fabricante : Wayne
Arquivo Tamanho: 2.18 mb
Arquivo Nome : ddb09f06-428b-4300-b17b-e84189590178.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Excessive water temperature 2. Defective switch or entangled switch is causing pump to run dry 3. Low line voltage 1. Pump should not be used for water above 120° 2. Replace or reposition pump Pump may start unexpectedly. Disconnect power supply before servicing 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company Pump operates noisily 1. Worn bearings 1. Return for service or replace or vibrates excessively 2. Debris in impeller cavity or 2. Remove housing, clean impeller and/or replace broken broken impeller 3. Piping attachments to building 3. Replace portion of discharge pipe with flexible connector structure too rigid or too loose Pump will not shut off 1. Defective float switch 1. Replace float switch 2. Float switch movement restricted 2. Reposition pump or clean basin as required to provide adequate clearance for float 3. Restricted discharge (obstruction 3. Remove pump and clean pump & piping in piping) 4. Excessive inflow or pump not 4. Recheck all sizing calculation to determine proper pump properly sized for application size Pump operates but delivers little or no 1. Low line voltage 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact water 2. Debris caught in impeller or power company discharge 2. Remove, clean and check for tightness 3. Worn or defective pump parts or 3. Replace worn parts or entire pump. Clean parts if required plugged impeller 4. Pump running backwards 4. Check rotation. (CCW from bottom) Return if CW 5. Pump not properly sized for 5. Recheck all sizing calculations to determine proper pump application size 6. Check valve stuck closed or 6. Remove and examine check valve for proper installation installed backwards and free operation 7. Shut off valve closed 7. Open valve 5 Operating Instructions and Parts Manual Troubleshooting Chart - CSECAP40, CSECAP50 Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Water level too low 2. Blown fuse or tripped circuit breaker 3. Low line voltage 4. Defective motor 5. Defective “Switch-Genius” 6. Impeller (pump filled with debris) 7. Insufficient liquid level 1. “Switch-Genius” water sensor will not turn pump on unless water is within 1 inch of the top of the sensor. 2. If blown, replace with proper sized fuse or reset breaker 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company. 4. Return for service or replace motor 5. Replace “Switch-Genius” 6. If impeller will not turn, remove housing and remove debris 7. Make sure liquid level is at least 11" from the basin floor Pump starts and stops too often 1. Backflow of water from piping 2. Dirty “Switch-Genius” water 1. Install check valve 2. Reposition pump, clean sensor face (Figure 3B). sensor 3. Check valve not installed or leaking 4. Discharge head is less than manufacturer’s minimum 3. Remove and examine check valve for proper installation and free operation 4. Recheck all sizing calculations to determine proper pump size Pump shuts off and turns on independently of switch (trips thermal overload protection) 1. Excessive water temperature 1. Pump should not be used for water above 120° Pump may start unexpectedly. Disconnect power supply before servicing 2. Low line voltage 2. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company Pump operates noisily or vibrates excessively 1. Worn bearings 2. Debris in impeller cavity or broken 3. Piping attachments to building structure too rigid or too loose 1. Return for service or replace 2. Remove housing, clean impeller and/or replace broken impeller 3. Replace portion of discharge pipe with flexible connector Pump will not shut off 1. Defective “Switch-Genius” switch 2. Restricted discharge (obstruction in piping) 3. Excessive inflow or pump not properly sized for application 1. Replace “Switch-Genius” switch 2. Remove pump and clean pump & piping 3. Recheck all sizing calculation to determine proper pump size Pump operates but delivers little or no 1. Low line voltage 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact water power company 2. Debris caught in impeller or discharge 2. Remove, clean and check for tightness 3. Worn or defective pump parts or 3. Replace worn parts or entire pump. Clean parts if required plugged impeller 4. Pump running backwards 4. Check rotation. (CCW from bottom) Return if CW 5. Pump not properly sized for 5. Recheck all sizing calculations to determine proper pump application 6. Check valve stuck closed or size 6. Remove and examine check valve for proper installation installed backwards and free operation 7. Shut off valve closed 7. Open valve 6 CSECAP40, CSECAP50, CSE50T For Replacement Parts or Technical Assistance, call 1-80...

Este manual também é adequado para os modelos :
Canalização - CSE50T (2.18 mb)
Canalização - CSECAP40 (2.18 mb)
Canalização - CSECAP50 (2.18 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias