Log:
Assessments - 5, GPA: 3.2 ( )

Instruções de Operação Giant, Modelo LP250

Fabricante : Giant
Arquivo Tamanho: 431.46 kb
Arquivo Nome : 8e61e325-4344-498d-9565-4210a3aaa9f6.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The plunger pipe (29B) should not be strained by over tightening of the tension screw (29C) or through damage to the front surface of the plunger; otherwise, it will probably break. 12. Place valve vasing (43) over studs and push firmly until seated against the crankcase (1). Tighten the hexagon nuts (49A) in a crosswise pattern (shown below) to 59 ft.-lbs. To Dismantle Gear End After removing valve casing (43) and plunger pipe (29B), drain oil. Remove gear cover (4) and bearing cover (14). Loosen connecting rod screws (24A) and push the front of the connecting rod (24) forward as far as possible into the crosshead guide. IMPORTANT! Connecting rods (24) are marked for identification. Do not twist connecting rod halves. Connecting rod is to be reinstalled in the same position on shaft journals. Turning the crankshaft (22) slightly, hit it out carefully to the side with a rubber hammer. IMPORTANT! Do not bend the connecting rod (24) shanks. Check crankshaft (22) and connecting rod (24) surfaces, radial shaft seals (15) and taper roller bearings (20). To Reassemble Using a soft tool, press in the outer bearing ring until the outer edge lines up with the outer edge of the bearing hole. Remove bearing cover (14) together with radial shaft seal (15) and o-ring (16). Fit crankshaft (22) through bearing hole on the opposite side. Press in outer bearing and tighten it inwards with the bearing cover, keeping the crankshaft in vertical position and turning slowly so that the taper rollers of the bearings touch the edge of the outer bearing ring. Adjust axial bearing clearance to at least 0.1mm and maximum 0.15mm by placing fitting discs (20A and 20B) under the bearing cover. IMPORTANT! After assembly has been completed, the crankshaft should turn easily with very little clearance. Tighten connecting rod screws (24A) to 310 in.-lbs. LP200, LP2S0 & LP2S0W-MT TORQUE SPECIFICATIONS n io № Item# Description Toraue Amount 24 tfORO Inner Hex Screw, Connecting Rod ЗЮ in.-lbs. 29C O7Bl Tension Screw, Plunger ЗЮ in.-lbs. 48 O7l56 Plug, Discharge lO7 fblbs. 49A O7l58 Hexagon Nut, Stud Bolts 59 fl.-lbs. Pump Mounting Selection Guide Bushings O6496 - 35mm H Bushing Pulley & Sheaves 0716S - 12.75” Cast Iron - 4 gr. - AB Section Rails O73S7 - Plated Steel Channel Rails (L=11.75”xW1.88”xH=3.00”) PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/or the Delivery Drops Worn packing seals Replace packing seals Broken valve spring Replace spring Belt slippage Tighten or Replace belt Worn or Damaged nozzle Replace nozzle Fouled discharge valve Clean valve assembly Fouled inlet strainer Clean strainer Worn or Damaged hose Repair/Replace hose Worn or Plugged reliefvalve on pump Clean, Reset, and Replace worn parts Cavitation Check suction lines on inlet of pump for restrictions Unloader Check for proper operation Water in crankcase High humidity Worn seals Reduce oil change interval Replace seals Noisy Operation Worn bearings Cavitation Replace bearings, Refill crankcase oil with recommended lubricant Check inlet lines for restrictions and/or proper sizing Rough/Pulsating Operation with Pressure Drop Worn packing Inlet restriction Accumulator pressure Unloader Cavitation Replace packing Check system for stoppage, air leaks, correctly sized inlet plumbing to pump Recharge/Replace accumulator Check for proper operation Check inlet lines for restrictions and/or proper size Pressure Drop at Gun Restricted discharge plumbing Re-size discharge plumbing to flow rate of pump Excessive Leakage Worn plungers Worn packing/seals Excessive vacuum Cracked plungers Inlet pressure too high Replace plungers Adjust or Replace packing seals Reduce suction vacuum Replace plungers Reduce inlet pressure High Crankcase Temperature Wrong Grade of oil Improper amount of oil in crankcase Giant oil is recommended Adjust oil level to proper amount Preventative Maintenance Check-List & Recommended Spare Parts List Check Daily Weekly SOhrs s £ ® w ® S Every ISOO hrs Every 3OOO hrs Oil Level/Quality X Oil Leaks X Water Leaks X Belts, Pulley X Plumbing X Recommended Spare Parts Oil Change (I Gallon) p/n 1154 X X Oil Seal Kit (I kit/pump) (See page 5 for kit lit) X Valve Spare Parts (1 kit/pump) (See page 5 for kit list) X 10 LP2OO, LP25O & LP25OW-MT DIMENSIONS GIANT INDUSTRIES LIMITED WARRANTY Giant industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of charge. Our other pump parts, used in portable pressure washers and in car wash applications, are warranted for five years from the date of shipment for all pumps used in NONSALINE, clean water applications. 2. One (I) year from the date of shipment for all other G...

Este manual também é adequado para os modelos :
Canalização - LP200 (431.46 kb)
Canalização - LP250W-MT (431.46 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias