Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Wayne, Modelo 330102-001

Fabricante : Wayne
Arquivo Tamanho: 879.58 kb
Arquivo Nome : 14efa996-8f63-47ae-817c-cd09ad52b8b5.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Defective float switch 1. Replace float switch off 2. Float switch movement restricted 2. Reposition pump or clean basin as required to provide adequate clearance for float 3. Restricted discharge (obstruction in 3. Remove pump and clean pump & piping piping) 4. Excessive inflow or pump not properly 4. Recheck all sizing calculation to determine proper pump size sized for application Pump operates but delivers little or no water 1. Low line voltage 2. Debris caught in impeller or discharge 3. Worn or defective pump parts or plugged impeller 4. Pump running backwards 5. Pump not properly sized for application 6. Check valve stuck closed or installed backwards 7. Shut off valve closed 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company 2. Remove, clean and check for tightness 3. Replace worn parts or entire pump. Clean parts if required 4. Check rotation. (CCW from bottom) Return if CW 5. Recheck all sizing calculations to determine proper pump size 6. Remove and examine check valve for proper installation and free operation 7. Open valve 4 5 Model EFL33 1 Motor housing 28088-001 1 2 Power cord 31026-001 1 3 #8 - 16 x 1 inch screw 67112-001 6 4 Motor housing gasket 17456-002 1 5 Impeller 17317-001 1 6 Volute (includes 6 screws) 23272-001 1 7 Dielectric oil 55932 2.2 pints 8 Mechanical switch kit 60022-001 1 9 Oil plug 37303-001 1 Reference Number Description Part Number Quantity Repair Parts List For replacement parts, call 1-800-237-0987 Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: Wayne Water Systems 101 Production Drive Harrison, OH 45030 U.S.A. OIL Tethered length to be 3 inches ± 0.25 inches Figure 4 Operating Instructions and Parts Manual Service Record Date Maintenance performed Repair components required Limited Warranty For one year from the date of purchase, Wayne Water Systems ("Wayne") will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model number and the serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions. thERE IS NO OthER EXPRESS WARRANty. IMPLIED WARRANtIES, INCLuDING thOSE OF MERChANtABILIty AND FItNESS FOR A PARtICuLAR PuRPOSE, ARE LIMItED tO ONE yEAR FROM thE DAtE OF PuRChASE. thIS IS thE EXCLuSIVE REMEDy AND ANy LIABILIty FOR ANy AND ALL INDIRECt OR CONSEQuENtIAL DAMAGES OR EXPENSES WhAtSOEVER IS EXCLuDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages. You MuSt retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MuSt send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions. DO NOt MAIL thIS FORM tO WAyNE. Use this form only to maintain your records. MODEL NO. _______________ SERIAL NO. ___________________________ INSTALLATION DATE _____________ AttACh yOuR RECEIPt hERE 6 Instructions d‘utilisation et Manual de Pieces Modele EFL33 Instructions d‘utilisation et Manual de Pieces Modele EFL33 Veuillez lire et conserver ces instructions. Lire attentivement avant de commencer a assembler, installer, faire fonctionner ou entretenir l‘appareil decrit. Protegezvous et les autres en observant toutes les informations sur la securite. Negliger d‘appliquer ces instructions peut resulter en des blessures corporelles et/ou en des dommages materiels ! Conserver ces instructions pour references ulterieures. Pompe Effluente Description Un systeme effl...

Este manual também é adequado para os modelos :
Canalização - EFL33 (879.58 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias