Follow all lock out/tag out procedures established by the user. Verify all power is off to the unit before performing any work. Failure to comply could result in serious injury, death or damage to the equipment. 1. Raise and lock driptray assembly (see Figure 1). Driptray Assembly Figure 1. 2. Clean out and dry driptray with a rag or paper towel, remove strainer if applicable (see Figure 2 and Figure 3). Upper Driptray Assembly Figure 2. Clean and Wipe Dry Inside Driptray Figure 3. Revisi
BE CAREFUL TO SECURELY HOLD DRAIN LINE TO AVOID DAMAGE TO UPPER DRIPTRAY!!! Cut PVC Drain Figure 5. 5. Deburr edge of PVC and re-plumb and clamp with new flexible tube/clamp supplied in kit (see Figure 6). MAKE SURE THAT THE INSULATION COVERS ALL EXPOSED TUBING/CLAMP! Figure 6. 6. Re-route new drain tube to floor drain. MAKE SURE THAT THERE ARE NO KINKS IN NEW DRAIN LINE! 7. Re-install driptray strainer if applicable. 8. Check driptray, fittings, and lines for leaks. 9. Lower upper driptr
Retain these instructions as part of your equipment manual. INSTALLATION PROCEDURE FOR FLAT FLOOR DRAINS 1. Mount the wire form support in the center of the floor drain grid and clamp it s four legs of the support onto the drain grid securely. If necessary, reform the legs to fit and attach firmly to the drain grid. The clamps are omitted for clarity on the first two illustrations. 2. Place the plastic splashguard collar over the wire form support. 3. The adjustable clamps will accomodate 1/