Log:
Downloads : 3   Arquivo Tamanho: 4 mb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

Water level too low 2. Blown fuse or tripped circuit breaker 3. Low line voltage 4. Defective motor 5. Defective float switch 6. Impeller (pump filled with debris) 7. Tangled switch 8. Insufficient liquid level 1. Pump switch will not turn on unless water covers top of pump 2. If blown, replace with proper sized fuse or reset breaker 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company. 4. Return for service or replace motor

Downloads : 0   Arquivo Tamanho: 4 mb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

6. Check hoses for weak and worn condition before each use, making certain that all connections are secure. 7. Periodically inspect the pump and system components. Perform routine maintenance as required (See Maintenance Section). 8. Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed. 9. Personal Safety: a.Wear safety glasses at all times when working with pumps. b.Keep work area clean, uncluttered and properly lighted; replace all unused tools and eq

Downloads : 5   Arquivo Tamanho: 2 mb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

If OK, contact water power company 2. Debris caught in impeller or discharge 2. Remove, clean and check for tightness 3. Worn or defective pump parts or 3. Replace worn parts or entire pump. Clean parts if required plugged impeller 4. Pump running backwards 4. Check rotation. (CCW from bottom) Return if CW 5. Pump not properly sized for 5. Recheck all sizing calculations to determine proper pump application 6. Check valve stuck closed or size 6. Remove and examine check valve for proper installa

Downloads : 4   Arquivo Tamanho: 2 mb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

5. A union should be installed between the check valve and the pump so the pump can be removed with least disturbance of the piping. 6. CSE50T models are supplied with a detachable tether switch with a piggyback plug (see figure 3A). The length of the tether (distance of cord from float to clamp) should not be set shorter than 3-1/4 inches and should not be used in a basin smaller than 14 inches in diameter. If using a differential other than the factory setting, be sure when the pump shuts off

Downloads : 6   Arquivo Tamanho: 2 mb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

Excessive water temperature 2. Defective switch or entangled switch is causing pump to run dry 3. Low line voltage 1. Pump should not be used for water above 120° 2. Replace or reposition pump Pump may start unexpectedly. Disconnect power supply before servicing 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company Pump operates noisily 1. Worn bearings 1. Return for service or replace or vibrates excessively 2. Debris in imp

Downloads : 4   Arquivo Tamanho: 2 mb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Sewage Pump Description A sewage system consists of a pump, control switch, and a basin for use in applications where less than six toilets (units) are discharged into the basin. The system is generally

Downloads : 2   Arquivo Tamanho: 880 kb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

Defective float switch 1. Replace float switch off 2. Float switch movement restricted 2. Reposition pump or clean basin as required to provide adequate clearance for float 3. Restricted discharge (obstruction in 3. Remove pump and clean pump & piping piping) 4. Excessive inflow or pump not properly 4. Recheck all sizing calculation to determine proper pump size sized for application Pump operates but delivers little or no water 1. Low line voltage 2. Debris caught in impeller or discharge 3. Wo

Downloads : 0   Arquivo Tamanho: 880 kb   Fabricante : Wayne  
Categoria : Canalização
@name@name@name

Check valve 45. Vent Inlet Gasket 1/2 inch Min. Clearance Basin Figure 3 - Prefabricated Basins 7. When a tether switch is used, rigid discharge pipe is required. If the pump is allowed to move, the tether switch could be restricted by the basin wall, preventing the pump from operating. Before removing pump from basin for service, always disconnect electrical power to pump and control switch. For any work on pump or switch, ALWAYS unplug the power cord. Do not just turn off circuit breaker or un

Downloads : 2   Arquivo Tamanho: 835 kb   Fabricante : Wayne  
Categoria : Canalização
@name

All models with a plug-in power cords system should still have a qualified electrician inspect the outlet being used to ensure proper wiring. Grounding Grounded Blade Outlet Power Cord Switch Cord Figure 3 TESTRESET The control switch is a wide-angle system which prevents short cycling of the pump motor and the consequential problems that short cycling can cause. The switch can be mounted on the discharge pipe (just above the pump discharge flange). See illustrations for switch mounting arrangem

Downloads : 0   Arquivo Tamanho: 835 kb   Fabricante : Wayne  
Categoria : Canalização
@name

Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Sewer Ejector Pump Description The submersible pump is designed for home applications. The unit is equipped with a 3-prong grounding type power cord. Motor is oil-filled and sealed for cooler running and designed to operate under water. This pump is not suitable for aquatic life, ponds or fountains.





categorias