Table 2 HP-UX October 2013 (AR1310) Fixes
Defect ID
Description
QXCR1001270184
This fixes the issue where system hang is seen because of a memory leak on SD2 systems during
continuous driver load and unload in a loop.
QXCR1001295252
This fixes the issue where the description for the LOM on BL8xxc i4 servers as part of the ioscan
output has an “N/A” string in the middle.
QXCR1001275632
This fixes the issue where devices configured under AVIO Stor HBA for an HP-UX 11i v3 guest
cannot be deleted if the guest is online.
Table 3 HP-UX March 2013 (AR1303) Fixes
Defect ID
Description
QXCR1001229792
This fixes a boot failure where server fails to boot with “-tm” option from a SAN device managed
by FCOC driver.
QXCR1001233852
This fixes a FCOC dump failure where compressed or concurrent dump may fail when three or
more devices are configured for OS crash dump.
QXCR1001208636 This fixes an issue where system may panic during port reset or cable pull sequence.
QXCR1001247588
This corrects an issue where system may panic due to race condition in handling of multiple ELS
requests.
QXCR1001174374
This fixes an issue where the FCOC driver may hang during repeated dynamic load and unload
(DLKM) sequence.
QXCR1001207506 This corrects an issue where HBA port may fail to come online after VC FlexFabric resets.
Table 4 HP-UX September 2012 (AR1209) Fixes
Defect ID
Description
QXCR1001179851
Installing or updating the FCOC driver no longer requires a reboot if the driver is not in use.
QXCR1001217140
This fixes a memory leak in the FCOC driver that occurs when a dynamic module unload is
executed.
QXCR1001205908 This fixes the issue where the FCOC driver hangs during dynamic loading (DLKM) when the
system is low in memory.
QXCR1001209093 This fixes a timing-related issue in the FCOC driver when an fcmsutil option is run while the driver
is being reset that may result in the driver hanging during unload.
QXCR1001205379 This fixes a timing-related issue in the FCOC driver that may cause a system panic if ELS requests
are in progress, especially when the driver is being reset or cable is being disconnected.
QXCR1001215209
QXCR1001208629
Table 5 HP-UX March 2012 (AR1203) Fixes
Defect ID
Description
QXCR1001144340
This fixes a timing-related hang issue in the FCOC driver that may occur when the driver is being
unloaded.
QXCR1001146915
This fixes fcocutil to print correct SFP information or print appropriate error message.
QXCR1001126158
This corrects a resource issue that may result in the FCOC driver never coming online after
repeated disables, enables, and resets, and subsequently being stuck in
"AUTHENTICATION/DISCOVERY" state as reported by fcmsutil
QXCR1001103767
This corrects a resource issue that may result in a system panic during FCOC driver unload.
QXCR1001158686
This corrects an issue that may result in a system panic during FCOC driver unload.
QXCR1001159017
This fixes a FCOC dump failure when crossing every 4GB page boundary.