Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP SAS Host Bus Adapters

Fabricante : HP
Arquivo Tamanho: 180.74 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


NOTE:
The target ID change does not occur on systems without a RAID-1 volume. It also
does not occur on HP Integrity Bl860c servers with the HP Multiport SAS Controller.
For detailed information on how to avoid or correct this problem, see Updating Internal SAS
Controller Firmware to Version 1.23.33 Or Later
at:
http://www.hp.com/go/sas-hba-docs

Before replacing a failed disk, note its Device Special File (DSF) information.
If you shut down a server to replace a failed disk offline, the DSF of the failed disk is not visible
in ioscan when the server restarts. The DSF is required by the replace_tgt command to
rebuild the array with the new disk.
Corrective Action: Before you shut down the server, run ioscan and note the DSF information
for the failed disk.
For more information on replacing disks, see the HP 8 Internal Port SAS Controller and HP
Multi-Port Internal SAS Controller Support Guide
at:
http://www.hp.com/go/sas-hba-docs
4.2 AH303A PCIe SC44Ge SAS Host Bus Adapter

Virtual Partitions do not boot in multi-initiator configurations under vPars A.4.05.
Virtual Partitions (vPars) version A.4.05 using an HP StorageWorks MSA60 or MSA70
enclosure do not boot if AH303A cards assigned to multiple virtual partitions are connected
to the same JBOD. Under the vPars I/O resource assignment rules, a host bus adapter cannot
be shared among multiple virtual partitions.
Corrective Action: This issue is corrected in vPars A.04.06 (B.11.23.0809).

Virtual Partitions do not boot if hardware reconfiguration changes the hardware path under
vPars A.4.05.
Virtual Partitions (vPars) using an HP StorageWorks MSA50/MSA60/MSA70 enclosure do
not boot if hardware paths change due to hardware reconfiguration. For more information
on the impacts of hardware reconfiguration, see the Ignite-UX and SAS Devices white paper
at:
http://www.hp.com/go/ignite-ux-docs
Corrective Action: This issue is corrected in vPars A.04.06 (B.11.23.0809).

There is a setboot command issue on specific servers.
The setboot -p/-a/-h command fails when issued on an AH303A adapter installed in
slots 3 or 4 on HP Integrity rx3600 and rx6600 systems.
Corrective Action: Install AH303A adapters in nonswitched slots. This issue is corrected in
patch PHKL_37869. You can download patches from the IT Resource Center at:
http://itrc.hp.com/
4 Known problems and limitations
5


...

Este manual também é adequado para os modelos :
Equipamento de rede - HP-UX 11i v2 I/O Cards (180.74 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias