Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação York, Modelo HORIZONTAL AIR RETURN CER00

Fabricante : York
Arquivo Tamanho: 203.52 kb
Arquivo Nome : a69f6742-b292-4e6d-a598-25454e44fbaf.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


fan speed and automatic change over CER30 (Wall mounted) Thermostat with auto. fan speed and automatic change over for modulating valve Technical features Model YEFB 130 140 230 240 330 340 430 440 Total cooling capacity [kW] (1) max 6.01 6.92 8.81 10.61 11.15 14.06 17.86 23.31 med 5.13 5.81 7.27 8.55 9.39 11.58 16.28 20.95 mln 3.22 3.49 6.08 7.01 7.51 9.00 14.40 18.21 Heating capacity [kW] (2) max 7.90 8.90 12.34 14.62 15.20 18.84 24.38 30.36 med 6.61 7.32 9.84 11.36 12.49 15.07 21.83 26.79 mln 3.96 4.20 8.01 9.04 9.71 11.33 18.90 22.77 Air volume [m3/h] max 1153 1130 2158 2116 2639 2587 4129 4048 med 916 898 1553 1523 1994 1955 3505 3436 mln 494 484 1174 1151 1422 1394 2853 2797 Max. available external static pressure [Pa] 100 100 175 175 250 250 250 250 Sound pressure level [dB(A)](3) max 56 56 60 60 60 60 67 67 med 51 51 54 54 54 54 64 64 mln 41 41 49 49 48 48 59 59 Power supply [V-ph-Hz] 230 - 1- 50 Water connections G 1/2” F G 1/2” F G 1/2” F G 1/2” F G 1/2” F G 1/2” F G 1” M G 1” M (1) Room temperature 27°C d.b., 48% R.H. - Water temperature 7/12 °C (2) Room temperature 20°C, 50% R.H. - Water inlet temperature: 50°C - Water flow values as Cooling, accordingly to the EUROVENT standards and UNI ENV 1397 (3) Sound pressure level in 1 meter distance open field and 0 Pa external static pressure ill YORK Blower 4 to 24 kW ifSl Compatibility table / Codes Models YEFB 130-140 YEFB 230-240 YEFB 330-340 YEFB 430-440 Options (factory fitted) Auxiliary hot water coil (2 or 3 rows) • • • • Paint finish • • • • F5 Filter • • • • Accessories (supplied loose) Valve kits 3 ways 4 ports On/off 2 and 4 pipes J3B2 J3C2 Modulating 2 and 4 pipes J3BM J3CM Electrical heaters Capacity (W) 3000 6000 9000 Controls CSR00 fan speed selector • • • • CMR00 2 and 4 pipe, on/off valves • • • • CER00 2 and 4 pipe, on/off valves (or El. heater) • • • • CER20 2 and 4 pipe, on/off valves (or El. heater) • • • • CER30 2 and 4 pipe, modulating valves • • • • Discharge plenum KPM 100-200 KPM 300 KPM 400 Condensate pump KPC 100-400 • Available Dimensions and minimum spaces Mod. A B C D E F G H 100-200 989.6 800 331 948.6 290 21.5 362 158 300 1239.6 900 350 1198.6 309 21.5 462 158 400 1633 900 439.3 1592 398.3 21.5 450 158 Mod. A B C 100-200 331 954 306 300 350 1 204 300 400 440 1 597 311 E-COM-H0707 Ü1YORK...

Este manual também é adequado para os modelos :
Sistemas de ventilação - HORIZONTAL AIR RETURN CER20 (203.52 kb)
Sistemas de ventilação - HORIZONTAL AIR RETURN CMR00 (203.52 kb)
Sistemas de ventilação - HORIZONTAL AIR RETURN CSR00 (203.52 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias