Fabricante : Datalogic Scanning
Arquivo Tamanho: 2.73 mb
Arquivo Nome :
|
Facilidade de uso
By adjusting the mounting bracket guides, reach 45° for the Skew angle (S in the figure below) to avoid the direct reflection of the laser light emitted by the scanner: If using the “45° Skew” installation, it is not guaranteed that the scanner reading performances (see reading diagram section) will match those measured for the standard installation with Skew angle between 10° - 20°. ATTENTION The ST-210 mounting bracket is an accessory of the DS6500 standard model available in the US-60 kit (order no. 890001020). NOTE When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved. WARNING Reading Conditions: • ANSI Grade B minimum • 800 scans/sec The following tables describe the requirements for standard applications. Casella di testo: T Casella di testo: Conveyor Direction Casella di testo: S Casella di testo: 45° Casella di testo: S Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 2/5 Interleaved Code Resolution (mm) 0.25 10 12 14 16 18 20 7 9 10 12 13 15 0.30 12 14 15 17 19 21 8 9 11 12 14 15 0.33 13 14 16 18 20 22 8 10 11 13 14 16 0.38 14 16 18 19 21 23 9 11 12 14 15 17 0.50 18 19 21 23 25 26 11 12 14 15 17 18 0.72 24 25 27 28 30 32 15 16 17 19 20 22 1.00 33 34 35 36 38 40 20 21 22 23 25 26 Ratio 3:1 Table 1 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 Code 39 Code Resolution (mm) 0.25 9 10 12 14 16 17 6 7 9 10 12 13 0.30 10 11 13 15 17 18 7 8 9 11 12 14 0.33 11 12 13 15 17 19 7 8 10 11 13 14 0.38 12 13 14 16 18 20 8 9 10 12 13 15 0.50 15 16 17 18 20 22 10 10 11 13 14 16 0.72 20 21 22 23 24 26 13 13 14 15 17 18 1.00 27 28 29 30 31 32 17 17 18 19 20 21 Ratio 3:1; Interdigit = Module Size Table 2 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 Code 128 – Ean 128 Code Resolution (mm) 0.25 8 9 11 13 15 17 5 7 8 10 11 13 0.30 8 10 12 14 16 18 6 7 9 10 12 13 0.33 9 11 13 14 16 18 6 8 9 11 12 14 0.38 10 11 13 15 17 19 7 8 10 11 13 14 0.50 12 13 15 17 19 21 8 9 11 12 14 15 0.72 16 17 19 21 22 24 10 11 13 14 16 17 1.00 22 23 24 25 27 29 13 14 15 17 18 20 Table 3 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 Codabar Code Resolution (mm) 0.25 8 9 11 13 15 17 5 7 8 10 11 13 0.30 9 10 12 14 16 18 6 7 9 10 12 13 0.33 9 11 13 14 16 18 6 8 9 11 12 14 0.38 10 11 13 15 17 19 7 8 10 11 13 14 0.50 13 14 15 17 19 21 8 9 11 12 14 15 0.72 17 18 19 21 22 24 11 12 13 14 16 17 1.00 23 24 25 26 27 29 14 15 16 17 18 20 Ratio 3:1; Interdigit = Module Size Table 4 Minimum Code Height for ACR Reading (mm) 45° 30° Conveyor Speed (m/s) 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 EAN 8-13, UPC-A Code Resolution (mm) 0.25 7 9 10 12 14 16 5 6 8 9 11 12 0.30 8 9 11 13 15 17 6 7 8 10 11 13 0.33 9 10 11 13 15 17 6 7 9 10 12 13 0.38 10 11 12 14 16 18 7 7 9 10 12 13 0.50 12 13 14 15 17 19 8 9 10 11 13 14 0.72 16 17 18 19 20 22 10 11 12 13 14 16 1.00 22 23 24 24 25 26 13 14 15 16 16 18 Table 5 Reading Diagrams: In the following reading diagrams (0,0) is the center of the laser beam output window. DS6500-100-0XX CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 4(in)812160 1020304050(cm)60202480 32 (in) (cm) 0-10-20-30-8 -12 -4 0 -40-16 -50-20 104 208 0.25 mm (10 mils) 0.3 mm (12 mils) 90 36 100 40 70284016 5020 3012 0.375 mm (15 mils) DS6500-105-0XX CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 4(in)812160 1020304050(cm)60202480 32 (in) (cm) 0-10-20-30-8 -12 -4 0 -40-16 -50-20 104 208 0.25 mm (10 mils) 0.3 mm (12 mils) 90 36 100 40 70284016 5020 3012 0.375 mm (15 mils) Reading Diagrams: DS6500-200-0XX CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 14(in)2026320 3550658095(cm)1103844140 56 (in) (cm) 0-15-30-45-12 -18 -6 0 -60-24 -75-30 156 3012 0.5 mm (20 mils) 155 62 170 68 125506024 7530 4518 0.375 mm(15 mils) DS6500-205-0XX CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 10° - 20° Tilt angle = 0° 0 14(in)2026320 3550658095(cm)1103844140 56 (in) (cm) 0 -15-30-45-12 -18 -6 0 -60-24 -75-30 156 3012 0.5 mm (20 mils) 0.375 mm(15 mils) 155 62 170 68 125506024 7530 4518 User Interface: RS232 PC-side connections 1 5 9 6 9-pin male connector 13 25 141 25-pin male c...
Este manual também é adequado para os modelos :Scanner / Copiadora / MFP - DS6500 (2.73 mb)
Scanner / Copiadora / MFP - DS6500-100-010 (2.73 mb)
Scanner / Copiadora / MFP - DS6500-100-011 (2.73 mb)
Scanner / Copiadora / MFP - DS6500-100-015 (2.73 mb)