|
Facilidade de uso
Adjustable Exhaust Deflector Rubber Comfort Grip Staple Loading Area Swivel Plug Pull-out Warning Decal Magazine Trigger Trigger Lock Magazine Latch Figure 4 - Components of the Stapler 8 Operating Instructions and Parts Manual CHN71600 9 Set-Up Lubric ation This tool requires no lubrication for normal operation. However, lubrication will not harm the tool. The work surface can become damaged by excessive lubrication. Minim um Comp onents Required For Hook-up AIR COMPRESSOR: The air compressor must be able to maintain a minimum of 60 psi when the tool is being used. An inadequate air supply can cause a loss of power and inconsistent driving (see Chart 1). PRESSURE REGULATOR: A pressure regulator is required to control the operating pressure of the tool between 60 psi and 100 psi. AIR SUPPLY HOSE: Always use air supply hoses with a minimum working pressure rating equal to or greater than the pressure from the power source, or 150 psi, whichever is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 3/8 inch air hoses for 50 foot run or longer (see Figure 5 and Chart 2). Hook-up Ins tructions For Stapler to Ai r Supp ly Figure 6 shows the recommended hookup for the tool. NOTE: For better performance, install a 3/8 inch quick plug (1/4 inch NPT threads) with an inside diameter of 0.315 inch (8 mm) on the tool and a 3/8 inch quick coupler on the air hose. 1. With ON/OFF switch in OFF position, plug compressor into electrical outlet. 2. Close pressure regulator by turning all the way to the left. Turn compressor ON and let it pump all the way up to automatic shut-off pressure. 3. Attach air hose to regulator outlet. Adjust pressure regulator by turning to the right so that outlet pressure is between 60 psi to 100 psi. 4. Load fasteners into tool (See Loading/Unloading the Stapler section on page 10). 5. Point the tool in a safe direction while attaching to air hose. 6. Tool is ready for use. You may need to adjust outlet pressure to achieve proper fastener depth. 60 psi Minimum 100 psi Maximum Chart 1 Ai r Hose Requirements Diam eter Length of Run 1/4 inch Less than 50 feet 3/8 inch Greater than or equal to 50 feet Chart 2 Figure 5 - Air Hose Requirements Interior Diameter Rated 150 psi or greater Quick Coupler Air Hose Figure 6 - Recommended Hookup Tank Pressure Gauge Outlet Pressure Gauge Regulator Outlet Regulator Quick Coupler Quick Plug Swivel Plug Operating Instructions and Parts Manual CHN71600 Set-Up (Continued) loadINg / uNloadINg tHe StaPler Choose which type of fastener you want to use for you project. Additional fasteners can be found at major home centers. loading the Stapler Always disconnect the tool from the air supply before loading / unloading fasteners. 1. Press down on latch and pull back on the magazine cover. 2. Insert a stick of Campbell Hausfeld staples or equivalent (see “Fasteners” section) into the magazine. Make sure the staples are not dirty or damaged. 3. Push the magazine cover forward until the latch catches. unloading the Stapler Always disconnect the tool from the air supply before loading / unloading fasteners. 1. Press down on latch and pull back on the magazine cover. 2. Remove fasteners. 3. Push the magazine cover forward until the latch catches. Figure 7 - loading the stapler Operation oPeratIoNal Mode Always know the operational mode of the tool before using. Failure to know the operational mode could result in death or serious personal injury. trIgger oNly Mode (WItH trIgger loCk) The tool is a single-actuator device. This mode requires that, with the trigger lock not positioned in the safe mode, only a pull of the trigger will fire a fastener. After verifying there are no fasteners in the tool, safety check the operation of the activated trigger lock to prevent the tool from firing a fastener before storage. Always disconnect from compressed air when not in use. oIl Lock Unlock Figura 8 10 Operating Instructions and Parts Manual CHN71600 Storage The stapler should be stored in a cool dry location. Maintenance ClearINg a jaM FroM tHe StaPler 1. Disconnect stapler from air supply. 2. Remove all fasteners from the magazine (see Loading/ Unloading). Failure to do so may cause the fasteners to eject from the front of the stapler. 3. Press magazine latch (see Loading / Unloading the Stapler). 4. Open the magazine, exposing the jammed fastener. 5. Remove the jammed fastener, using pliers or a screwdriver if required. 6. Load with staples. 7. Make sure the trigger moves freely without sticking or binding. StaPler rePaIr Only qualified personnel should repair the tool and they should use genuine Campbell Hausfeld replacement parts and accessories, or parts and accessories which perform equivalently. rePlaCeMeNt PartS Use only genuine Campbell Hausfeld service parts. Tool performance, safety and durability could be reduced if improper parts are used. When ordering replacement parts, specify by part number. aSSeMbly ProCedure F...
Este manual também é adequado para os modelos :Pistola de pregos - CHN71600 (5.75 mb)