If it is necessary to reset the drying and cooling times for the current cycle, press STOP once to stop the tumbler. Press STOP again to cancel the cycle. If it is necessary to change programs during a current cycle, press STOP once to stop the tumbler and press STOP again to cancel the current cycle. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions DMP Coin DV Control Suffix Description of The Coin Control Panel Refer to Figure 5. TMB1955N 1 Clock Symbol. This symbol of a clock indicates that the time in the display is counting down to zero. 2 Display. Displays the drying time, cooling time, drying temperature, and diagnostics. 3 Hidden Keys. Used for programming in the coin mode – increases or decreases the value in the display. In conjunction with the START button, these buttons are used to adjust the drying time, cooling time, temperature, clockwise time, dwell time, counterclockwise time, and minutes per coin. 4 Temperature LEDs. Indicate temperature setting. 5 DRYING LED. Illuminated when in the drying cycle. 6 INSTRUCTIONS. Instructions to start a drying cycle. 7 COOLING LED. Illuminated when in the cooling cycle or when the display is currently showing the time for the cooling cycle. 8 START. Starts or resumes the current program or cycle 9 Temperature Select. This button toggles through the three temperature selections. DRYING PERM. PRESS COOLING INSTRUCTIONS START TEMP INSERT COIN (S) SELECT TEMP. PUSH START 1 2 3 MINUTES MEDIUM LOW 8 9 12 3 4 5 6 7 Figure 5 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400201 15 Operating Instructions DMP Coin Features Coin Keypad Interface - START button to start or resume a cycle. - TEMP button to select HIGH, MEDIUM, or LOW temperature. - Two hidden buttons to increment or decrement the programmable time and temperature options. Power-Up Upon applying power to the tumbler, the display will show “PAy” and the DRYING and COOLING LEDs will be off until coins are deposited to increase the tumbler run time. When time is displayed, the default (LOW) temperature setting LED will be on until a different temperature setting is selected. Power Failure If a power loss occurs during operation, a cycle will not resume until the START button is pressed. To cancel the remaining cycle, press the internal CLEAR button. Coin Operation The tumbler run time is determined by the pre- programmed run time per coin and the number of coins deposited into the tumbler. The maximum time that can be accumulated and displayed is 99 minutes. The drying time is the difference between the run time and the cooling time. The cooling time is pre- programmed to be 2 to 5 minutes. The drying temperature can be selected from LOW, MEDIUM, or HIGH temperature settings by pressing the TEMP button. Coin Programming The Coin board programming mode can only be entered when “PAy” is displayed. DIP switch #7 must be in the OFF position. Programming is enabled by setting DIP switch #8 to the ON position. The programming mode is entered by pressing and holding the CLEAR button for three seconds. The programming follows the following parameter order: 1. Tumbler run time per coin (DRYING), COOLING time, HIGH temperature setpoint, MEDIUM temperature setpoint, LOW temperature setpoint. 2. An LED will be on to indicate which parameter is flashing on the display. 3. The hidden front panel increment and decrement keys are used to change the value. 4. The CLEAR button is used to recall the default value. 5. The START button is used to step to the next parameter. 6. After the last parameter, “End” will be flashing. 7. Press the START button one last time to store the settings and exit the program mode. 8. “PAy” will be displayed. 9. If it is determined that the data did not program correctly, the error message “E2F” will flash for 4 seconds, and then the default coin parameters will be used. The tumbler run time per coin is programmable for 1 to 20 minutes with the default preset to 10 minutes. The cooling run time is programmable from 2 to 5 minutes with the default preset to 2 minutes. The three temperatures setpoints are programmable for 100.F (38.C) to 185./195.F (85./90.C) with the following default settings: -HIGH equal to 185.F (85.C) - MEDIUM equal to 150.F (66.C) - LOW equal to 135.F (57.C) Stop When in the Coin mode, the tumbler will stop if the tumbler door is opened while the tumbler is running. If the CLEAR button, located behind the board, is pressed, the tumbler will stop, the tumbler time will be zeroed and the display will show “PAy.” Coin Count The unit will count the number of coins deposited. Setting DIP switch #7 to the ON position will display the coin count since it was the last reset. To reset the count, press the CLEAR button and “00” will be displayed. If the coin count is greater than “999,” the display will flash “999.” Setting DIP switch #7 to the OFF position will return the display to “PAy.” © Copyright, Alliance Laundry ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias