Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Hotpoint, Modelo NVLR333EVAA

Fabricante : Hotpoint
Arquivo Tamanho: 66.04 kb
Arquivo Nome : 5a318b7d-79bb-4713-9edf-18b44791b6a0.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Gas Dryer Electric Rating: 120V, 60Hz, 15 Amp Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply requires a conversion kit. Check installation instructions for correct kit and have a qualified gas technician install a conversion kit. See dryer ducting information for proper installation. Installation Information: For complete information, see installation instructions packed with product for current dimensional data. R Listed by Underwriters Laboratories Specification Revised 8/99 NVLR333GVWW—Hotpoint Dryer Exhausting Information—For complete information, see installationinstructions packed with your dryer. Domestic Dryer Models 4 B 2-1/2 A Super & Extra-Large Capacity Models All Electric Dryers Super & Extra-Large Capacity Models All Gas Dryers Large Capacity Electric and Gas Dryers Specification Revised 8/99 Number of 90° Turns 0 1 2 3 4 0 1 2 3 0 1 2 3 4 Best Performance Maximum Length of 4" Dia. Rigid Metal Duct Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 90 ft. 60 ft. 45 ft. 35 ft. 25 ft. 45 ft. 35 ft. 25 ft. 15 ft. 60 ft. 52 ft. 44 ft. 32 ft. 28 ft. B 2-1/2" Opening 60 ft. 45 ft. 35 ft. 25 ft. 15 ft. 30 ft. 20 ft. 10 ft. — 48 ft. 40 ft. 32 ft. 24 ft. 16 ft. Important Note: GE Kit Number WE14X70 needed when converting rear Maximum Length of 4" Ducting Materials: Dia. Flexible Metal Duct For best performance, this dryer should be vented with 4” diameter be Exhaust Hood Type Cat. No. WX8X59 (Preferred) A 4" Opening 55 ft. 40 ft. 30 ft. 20 ft. 15 ft. 30 ft. 20 ft. 10 ft. — 30 ft. 22 ft. 14 ft. — — used, then “flexible all metal” venting can be used, but it will Exhaust Length Calculation: B 1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom add one turn. 2-1/2" Opening 2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can 45 ft. for flexible ducts are less than for rigid duct. 30 ft. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° 20 ft. 15 ft. should be treated as a 90° elbow. 10 ft. Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being 15 ft. blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. 10 ft. — Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an — attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never a 18 ft. common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create 14 ft. 10 ft. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The — ft. located at least 12” above the ground or any other obstruction with the opening pointed Down. — ft. Other terminations, such as louvered wall boxes, are acceptable provided they are e...

Este manual também é adequado para os modelos :
Secadores - NVLR333GVAA (66.04 kb)
Secadores - NVLR333GVWW (66.04 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias