Instruções de Operação Kenmore, Modelo 134316200

Fabricante : Kenmore
Arquivo Tamanho: 2.69 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


On gas dryers, exhausting can be to the right side of the cabinet or the bottom of the dryer. Directional exhausting can be accomplished by installing Exhaust Kit, P/N 131456800, available through your parts distributor. Follow the instructions supplied with the kit. EXHA LISTDUCTLOCATINGDIMENSIONS SAME AS OTHER SIDE GAS SUPPLY REQUIREMENTS Replace copper connecting pipe that is not plastic-coated. Stainless steel or plastic-coated brass MUST be used. 1. Installation MUST conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition). 2. The gas supply line should be of 1/2 inch (1.27 cm) pipe. 3. If codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass. 4. The gas supply line MUSThave an individual shutoff valve. 5. A 1/8 inch (0.32 cm) N.RT. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUSTbe disconnected from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures in excessof 1/2 psig (3.45 kPa). 7. The dryer MUSTbe isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). ROUGH-IN DIMENSIONS ._---_267/8" _1 (68.3 crn) 43/8" 1.2cm) m B ELECTRIC CONNECTION REAR ViEW 2 9116"---_ (6.5 cm) 13 1/2" 43 5/8' (11o.7cm) 36" 3/8" (0.96 cm) DIA. GAS 3 314' I" (2.54 cm) (9.5 cm) 47 1/2" (120.7 cm) DOOROPEN900 SIDE ViEW 4 318" (11.1 cm) OPTIONAL --_ VENTKNOCKOUT EZ3, e_ 27' (68.6 cm) (9.5 cm) (Figure 1) UNPACKING 1. Using the four shipping carton corner posts (two on each side), carefully lay the dryer on its left side and remove foam shipping base. To prevent damage, do not use the control panel or coin meter housing as a means to pick up or move the dryer. 2. Return the dryer to an upright position. FOAM SHIPPING PAD REVERSING DOOR SWING Your dryer is designed so the door swing may be reversed at any time without additional parts. Conversion is accomplished by transferring hinges to the opposite side of the cabinet. To change the direction of the door opening: 1. Open the dryer door. Remove the four hinge hole plugs from the left side of the door opening. Place nearby for future installation. NOTE: You may need a plastic knife to help pull out the plugs. Be careful not to scratch the paint. , Remove the four screws that secure the door hinges to the dryer front panel (see below). NOTE: Remove one screw from each of the two hinges first. Hold the door firmly before removing the last two screws. , Rotatethedoor180°andreinstallthedoorhingestothedryer front panel with the four screws. , Install the four hinge hole plugs in the open screw holes on the right side of the door opening. REMOVE 4 SCREWS (ONE FROM EACH HINGE FIRST) DO NOTINSTALL YOUR DRYER: 1. in an area exposed to dripping water or outside weather conditions. 2. Inanareawhere itwill comeincontactwith curtains,drapes, or anything that will obstruct the flow of combustion and ventilation air. 3. On carpet. Floor MUSTbe solid with a maximum slope of 1 inch (2.54 cm). iNSTALLATION iN RECESSOR CLOSET 1. A dryer installed in a bedroom, bathroom, recess or closet, MUSTbe exhausted outdoors. 2. No other fuel burning appliance shall be installed in the same closet as the Gas dryer. 3. Your dryer needs the space around it for proper ventilation. DO NOT INSTALL YOUR DRYER iN A CLOSET WITH A SOLID DOOR. -t- 0so.,.. CLOSET DOOR L DON'T 4. A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required. Air openings are required to be unobstructed when a door is installed. A Iouvered door with equivalent air openings for the full length of the door is acceptable. MINIMUM INSTALLATION CLEARANCES(inches) FRONT SIDES REAR TOP Alcove 0 (0 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm) Closet 1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm) Closet door ventilation required: 2 Iouvered openings each 60 square inches (387 square centimeters) --3 inches (7.6 cm) from bottom and top of door. THIS DRYERMUST BEEXHAUSTED OUTDOORS. 5. The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation. 1" (2.54 cm) i J_ DONIT-\ ..... DON'T Incorrect Rigid Metal Only ("_'\; ----L Correct Correct ELECTRICAL INSTALLATION GROUNDING REQUIREMENTS Before proceeding with electrical installation, install the dryer's coin-metering system (when used)in accordance with the separate instructions provided with the meter. /ILL ELECTR/CDryers II The following are specific requirements for proper and safe electrical installation of your dryer. Failure to follow these instructions can create electrical shock and/ or a fire hazard. This appliance MUST be properly grounded. Electrical sho...

Este manual também é adequado para os modelos :
Secadores - 134313400 (2.69 mb)
Secadores - 417.74182300 (2.69 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias