Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Hunter Fan, Modelo 47200A

Fabricante : Hunter Fan
Arquivo Tamanho: 308.35 kb
Arquivo Nome : 47200.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Connect Wires and Mount Thermostat to Wallplate ¦ Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not connected to the old thermostat. ¦ Refer to the Wiring Diagrams below to be sure your system is wired correctly. ¦ If your system is a single stage heat pump and uses an O or B wire, you must move the System Selector switch inside the thermostat to the Heat Pump position. If you have a normal furnace or electric system, leave the switch in the Standard position. Refer to the System Selector section for more information on this switch. ¦ Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat. ¦ Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate. ¦ Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO. ¦ Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE: Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.) ¦ Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment. ¦ Switch on the main power at the panel or furnace. Figure 4 Figure 5 Figure 2 G Rc Rh Y/O W/B Y1 x RH Figure 3 Figure 6 ® Wiring Diagrams Selector Switches In order for this thermostat to control your system, the system type must be specified by the 4-wire Heat/Cool System selector switches on the printed circuit board inside the thermostat. System Selector STD– HP JumperWallplate Terminals Fan Relay Cool Contactor Heat Relayor Valve 24V SupplyHeat/Cool RhRcY/OW/BY1GX X ¦ Heating System Selector (HG - HE switch) The factory position for this switch is in the “HG” position. Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected after installation. If the Fan operation is normal, leave it in the “HG” position. If the Fan does not come on within a minute of the thermostat calling for heat, change the switch position to “HE”. The system selector has no effect in the cooling mode. NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay. ¦ System Selector (STANDARD - HEAT PUMP switch) The factory position for this switch is in the STD position. Leave it in this position if you have 5-wire Heat/Cool System System Selector STD– HP ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no auxiliary or emergency heat source), then slide the switch to the HP position. Be sure the reversing valve wire is connected to the correct terminal for your heat pump (Y/O) or (W/B). ¦ Auto Recovery selector (DISABLE / ENABLE) Your thermostat is set from the factory with the Auto Recovery Feature enabled, which complies with the EPA ENERGY STAR® Program. If you prefer to use normal recovery, slide the switch to the DISABLE position. Auto Recovery (SW4) DISABLE ENABLE No JumperWallplate Terminals Fan Relay Cool 24V Supply Heat Relayor Valve Heat 24V Supply RhRcY/OW/BY1GCool Contactor X Single-stage Heat Pump System System Selector (SW5) HG HE Jumper X OR Heat Mode Cool Mode Connect to Proper Reversing Valve Terminal. See Table A Wallplate Terminals RhY/OW/BRcGFan ReversingCompressorHeat PumpRelay Valve Contactor Y124V Supply System Selector STD HP Fan Option (SW6) STD– HP Figure 7 C° / F° Selection (Celcius / Fahrenheit) Your thermostat is set for C° mode from the factory. To change to F° mode, follow these steps: 2-wire Heat Only System ¦ Press and hold the Up key. System Wallplate Jumper Selector ¦ Use a paper clip to press the reset key. Terminals RhRcY/OW/B GXX X X Heat 24V or Heat RelayMillivolt Supply or Valve Y1 3-wire Heat Only System ¦ Once all the LCD segments turn on, release the Up key. STD– HP NOTE: To return to C° mode, press the reset key with a paper clip. Do not press any other keys during the reset process. All programs and settings will be lost when pressing RESET. OPERATION Setting Day and Time System Selector STD– HP Jumper XX Wallplate Terminals Fan Relay RhRcY/OW/BY1GHeat 24V Supply X Heat Relayor Valve ¦ The LCD will show this information when batteries are first installed, or after the Reset button is pressed. The temperature will update after a few seconds. ¦ During time and day setting mode, the temperature and program displays will go blank. ¦ Example: Set the Thermostat to the current time of 2:16 pm on Saturday. Refer to the Steps below. M AM 4 TEMP 3-wire Cool Only System RhRcY/OW/BY1GJumper XX Wallplate Terminals CoolCool 24VFan ContactorSupplyRelay X System Selector STEP 1: STD– HP day...

Este manual também é adequado para os modelos :
Os termostatos - 47200A (308.35 kb)
Os termostatos - 47200A (308.35 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias