Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Aube Technologies, Modelo TH114

Fabricante : Aube Technologies
Arquivo Tamanho: 579.74 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


For maximum performance, the sensor probe should be centered between the wires in the mat (max. 80°C). • Push the excess wire into the wall, secure the base using the provided screws and wall anchors, and install the TH11x thermostat onto the base. • Once the thermostat is installed, return power to heating system and slave units and the master thermostat to ON. 3.4 Slave Units - GFCI Test We recommend you test the GFCI immediately after installing the thermostat, and once a month thereafter to ensure iting properly. If the test warning light comes ON dsystem from the main power panel he installation. • Slide the protective door upwards and make sure the switch is ON. is ope normal operation, cut power to heating • Press TEST. • The test is successful if the TEST warning light is ON and power is cut off. • If the test fails (first installation test): a. Verify installation b. Check the load wires c. Once you've identified the problem, run the GFCI test again • If the test fails (monthly maintenance): a. Cut power to heating system from the main power panel and call customer service • When the test is successful, reset the slave unit by switching from ON to STANDBY then back to ON. • Repeat steps 1 to 3 for all slave units. Technical Specifications Temperature: - Operation: 32°F to 122°F (0°C to 50°C) - Storage: -4°F to 122°F (-20°C to 50°C) TH113/TH114/TH115/TH116 (A/F/AF-12VDC) Power supply 12 V from remote unit Maximum up to 10 slave units per slave units master thermostat Wire gauge 20 AWG Size (H • W • D) 4.63 x 2.7 x 0.61 in. BASE (117.5 x 68.3 x 15 mm) NOTE: Refer to the TH11x user guide for technical specifications. CT230-120GA/120GB/240GA/240GB Supply - PB112-120 1800 W @ 120 VAC 60 Hz, 15 A resistive - PB112-240 3600 W @ 240 VAC 60 Hz, 15 A resistive GFCI GA=5 mA / GB=30 mA Certification c CSA us Size (H • W • D) 4.63 x 2.7 x 1.45 in. BASE (117.5 x 68.3 x 37 mm) Size (H • W • D) 4.67 x 2.74 x 0.67 in. INTERFACE (118.6 x 69.6 x 17 mm) Warranty Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or (ii) contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FO...

Este manual também é adequado para os modelos :
Os termostatos - CT230-120GB (579.74 kb)
Os termostatos - TH113 (579.74 kb)
Os termostatos - CT230-120GA (579.74 kb)
Os termostatos - CT230-240GA (579.74 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias