Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Aube Technologies, Modelo TH114

Fabricante : Aube Technologies
Arquivo Tamanho: 257.08 kb
Arquivo Nome : TH114-A-F-AF-024T-15S.pdf
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


The following models are available: Each thermostat consists of a control module which must be mounted on a PB112 Series power base. For the selection and installation of the power base, refer to its installation instructions. The DIP switches are located at the back of the control module. To switch between °C and °F. Note: Available on certain models only .. Refer to the installation instructions of the power base. .. Insert the tabs at the top of the control module in the slots at the top of the power base. .. Secure the control module using the captive screw underneath the base. Note: Do not obstruct the thermostat's vents. As soon as the thermostat is powered, it undergoes a series of tests before displaying the actual temperature. The measured temperature is below 0°C (32°F). Heating is turned On. The measured temperature is above 50°C (122°F) (A or AF model) or 60°C (140°F) (F model). The floor sensor is defective or not properly connected (F model only), or the thermostat is defective. Note: This procedure must be performed if the thermostat is mounted on a GFCI-equipped power base. Test the GFCI immediately after installing the control module, and once a month thereafter. .. Raise the temperature until the heating power indicator appears. .. Press the Test button. .. If the test is successful, you will hear a click caused by the GFCI relay tripping. The heating power indicator will disappear, GFI will appear and the Fault light will illuminate. Reset the thermostat by switching it to Standby and back to On. .. If the test has failed, cut power to the heating system from the main electrical panel and call customer service. Note: If the Fault light is On during normal operation, cut power to heating system at the main electrical panel and have an electrician verify the installation. ! A model: .. controls and displays the ambient temperature F model: .. controls and displays the floor temperature .. uses an external temperature sensor AF model: .. controls and displays the ambient temperature .. maintains the floor temperature within desired limits .. uses an external temperature sensor "# $! %& F: To select the F model AF: To select the A or AF model 1 to 24% 25 to 49% 50 to 74% 75 to 99% 100% GFCI test button * / Backlight button * Temperature adjustment button On/Standby button Power output Actual or setpoint Arrow appears temperature when the setpoint is displayed GFCI fault indicator * GFCI fault light * * available on certain models only ' " #$ ( ) * +%" , 1 ,1 2!!!&! ,-!. When either of the buttons is pressed, the display is lit for 10 seconds. The setpoint appears for 5 seconds, then the actual temperature is displayed. When the backlight button is pressed, the display is lit for 5 seconds. NOTE: If the thermostat is mounted on a GFCI-equipped power base, this button is used for the GFCI test. , The thermostat normally displays the actual temperature. To view the setpoint, press once on one of the buttons. The setpoint is displayed for 5 seconds. During the setpoint display, press one of the buttons to change it. To scroll the setpoint faster, press and hold the button. ,'+ /0+ The thermostat generally turns heating On or Off to control the ambient temperature. However, if the floor temperature drops below the set minimum floor temperature limit or rises above the maximum limit, the thermostat will turn heating On or Off respectively, regardless of the ambient temperature, to maintain the floor temperature within the desired limits. The minimum and maximum floor temperature limits are factory-set at 10°C (50°F) and 28°C (82°F) respectively. To modify the limits, proceed as follows: ..Switch the thermostat to Standby. ..While pressing any button, switch the thermostat back to On to access the floor temperature limit settings. ..Press the Test button briefly to switch between minimum and maximum floor temperature settings. ..Press the buttons to set the desired limit. ..Press the Test button for 3 seconds to save your modifications. After the data are saved, the thermostat displays the actual ambient temperature or “– –”. Note: Your modifications are also saved if no button is pressed for 60 seconds. ..Switch the thermostat to Standby and back to On to reset the GFCI and return to the normal display. : Power supply: Refer to the power base installation instructions. Ambient setpoint range (A/AF models): 5°C to 30°C (40°F - 86°F) Floor limit range (AF model): 5°C to 40°C (40°F - 104°F) Floor setpoint range (F model): 5°C to 40°C (40°F - 104°F) Setpoint resolution: ± 0.5°C (1.0°F) Display resolution: ± 0.5°C (1.0°F) Duty cycle: Refer to the power base installation instructions. Storage: -20°C to 50°C (-4°F - 120°F) 34 AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias