Log:
Assessments - 5, GPA: 3.8 ( )

Instruções de Operação Carrier, Modelo TP-NHP

Fabricante : Carrier
Arquivo Tamanho: 1.19 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Route wires through large hole in Equipment Control Module. Level Equipment Control Module against wall (for aesthetic value only . Equipment Control Module need not be leveled for proper operation) and mark wall through 4 mounting holes. To avoid unintended bending of wall plate plastic, use all 4 screws and anchors. 2. Drill four 3/16.in. mounting holes in wall where marked. Thermostat may be mounted to a standard junction box if desired. Hole pattern on Equipment Control Module matches junction box mounting holes. 3. Secure rear plastic Equipment Control Module to wall with 4 screws and anchors provided. To avoid unintended bending of wall plate plastic, use all 4 screws and anchors. Make sure all wires extend through hole in Equipment Control Module. 4. Adjust length and routing of each wire to reach proper connector block and terminal on Equipment Control Module with 1/4.in. (6 mm) extra length. See Fig. 14. 19 A07219 Fig. 14 . Equipment Control Module 5. Match and connect equipment wires to proper terminals of each connector block. 6. Push any excess wire into wall and against Equipment Control Module. Seal hole in wall to prevent air leaks. Leaks can affect operation and cause incorrect temperature measurement. 7. Remove 2.wire pigtail from thermostat mounting base and attach to Equipment Control Module terminal block (terminals V+ and Vg). Attach 2.wire pigtail to the back of the Display Module via 2 pin, keyed connector. 8. Reattach Display Module body to Equipment Control Module by first setting on at top and then push bottom corners to snap into place. See Fig. 15. 20 A07220 Fig. 15 . Reattach Display Module 9. Turn on power to equipment. On power up, all display segments will light for 5 sec. For the next 5 sec a 2.digit code appears on large display which identifies AC/HP Control configuration. Refer to Option 33. a.AC —1.stage air conditioner, AC, with furnace or fan coil b.HP —1.stage heat pump, HP only with fan coil c. H — heating only system, furnace only or fan coil with electric heat only d. C — cooling only system, AC with fan coil e.H2 —2.stage heat pump with fan coil f.A2 —2.stage air conditioner with fan coil or furnace Set AC/HP Control Configuration Configuration options enable the installer to configure the thermostat for a particular installation. Most are not presented to the homeowner and therefore 21 must be properly set by the installer. (Only those marked with an asterisk * below are available to the homeowner.) The homeowner configurations are described in the owner’s manual. A special procedure allows entry into the configuration mode. Description of each selection and how to use the configuration mode follows. CONFIGURATION OPTIONS . SUMMARY Option 01 — Equipment Type Option 02 — Clean Filter Timer Adjustment Option 03* — Fahrenheit/Centigrade Selection Option 04 — Fan (G) on with W/W1 Selection Option 05 — Room Air Temperature Sensing (programmable models only) Option 06 — Cooling Lockout Below 55F/13C Selection (only available if outdoor air sensor is present) Option 07 — Zoning Option 08 — Auxiliary Heat Lockout Temperature Setting (only available when heat pump is used and when outdoor air temperature sensor is present) Option 10 — Reversing Valve Option 11 — Adjustable Setpoint Deadband Option 12 — Smart Recovery (programmable models only) Option 13 — Room Temperature Offset Adjustment Option 15 — Enable Auto Mode Option 16 — Cycles Per Hour Option 17 — Time Between Stages 22 Option 18* — Backlight Configuration Option 19 — Dry Contact (programmable models only) Option 20 — Outdoor Air Temperature Offset Adjustment Option 21* — Keypad Lockout Option 24* — Programmable/Non.Programmable (programmable models only) Option 25* — Number of Programmable Periods per Day (programmable models only) Option 26 — Minimum Cooling Setpoint Option 27 — Maximum heating Setpoint Option 28 — UV Light Reminder Option 30* — Programmable Fan (programmable models only) Option 31* — Daylight Savings Time Configuration (programmable models only) Option 32 — Furnace Heat Staging Option 33 — Single or Two.Piece Installation Option 41 — Variable Speed Blower Option 44 — Super Comfort Heat Option 99 — Reset to Factory Defaults TO ENTER CONFIGURATION MODE Press and hold FAN button for approximately 10 sec. The Display Module is now in configuration mode. It will automatically exit this mode if no button is pressed for 3 minutes. Pressing either FAN or DONE button will exit configuration mode immediately. 23 WHILE IN CONFIGURATION MODE The option number is displayed in the heat setpoint location and the configuration setting is displayed in the cool setpoint location. On the TP.PAC/PHP (programmable) models, a box will surround the option number. The mode button is used to move the box between the two displayed values. The soft keys below the listed values may also be used to move the box between selected values. The value inside the box is changed by using the UP/DOWN buttons. On the TP.NAC/NHP (n...

Este manual também é adequado para os modelos :
Os termostatos - TP-NAC (1.19 mb)
Os termostatos - TP-PAC (1.19 mb)
Os termostatos - TP-PHP (1.19 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias