Instruções de Operação Carrier, Modelo TP-PAC

Fabricante : Carrier
Arquivo Tamanho: 1.19 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


When the keypad lock selection is turned on, the padlock icon will be displayed. To unlock the keypad, press and hold the UP/DOWN buttons simultaneously for five seconds. When the keypad is unlocked, the padlock icon will turn off. The keypad will remain unlocked for two minutes after the last button press. After two minutes with no button presses, the keypad will lock again. The keypad will not lock in the software configuration mode or in the installer test mode. Default is OF (off). 31 Option 22 — High Cool Latch Temperature (only available if outdoor sensor is present) An outdoor sensor is required for high cool latch feature. This selection is only available when Option 1 is set to H2, A2, or h2 and when Option 7 (zoning) is set to OF (off). Configuration settings are OF (off), 80, 85, 90, 95, 100, 105, 110, On. OF (off) — Cooling always starts in low stage (Y1) and stages up to high stage (Y1 and Y/Y2) when demand is sufficient and staging timer constraints have been satisfied. 80 to 110F (27 to 43C) — Outdoor temperature above which both first and second stages of the compressor are energized to satisfy all cooling demands. When a cycle starts under a high cool latch, it will finish the cooling cycle on high stage. On — The Y1 and Y/Y2 outputs are simultaneously energized to satisfy all cooling demands. Default is OF (off). Option 23 — High Heat Latch Temperature (only available if outdoor sensor is present) This selection is only available when Option 1 is set to H2, or h2 and Option 7 (zoning) is set to OF (off). Configuration settings are OF (off), 20, 25, 30, 35, 40, 45, 50, On. OF (off) —Heating always starts in low stage (Y1) and stages up to high stage (Y1 and Y/Y2) when demand is sufficient and staging timer constraints have been satisfied. 20 to 50F (.7 to 10C) — Outdoor temperature below which both first and second stages of the compressor are energized to satisfy all heating demands. 32 When a cycle starts under a high heat latch, it will finish the heating cycle on high stage. On — The Y1 and Y/Y2 outputs are simultaneously energized to satisfy all heating demands. Default is OF (off). Option 24 — Programmable/Non.Programmable This selection allows the installer to configure the thermostat as either programmable or non.programmable. Selections are P, nP. Default is P (programmable models only). Option 25 — Number of Programmable Periods This selection allows the installer to configure the thermostat for two or four periods per day. Two periods is a common commercial application and four periods is more common for residential. This selection is not available if Option 24 has been set to nP to configure the thermostat for non.programmable operation. 2 — Periods DAY and SLEEP are available 4 — Periods WAKE, DAY, EVE, and SLEEP are available. Default is 4. Option 26 — Minimum Cooling Setpoint This selection allows the installer to configure the minimum cooling setpoint that the user is allowed to set. The range is based on the value of the adjustable deadband Option 11, such that the minimum of the range is 50F/10C plus the adjustable deadband and the maximum is 90F/32C. Default is 52F/11C (based on the adjustable deadband default = 2). 33 Option 27 — Maximum Heating Setpoint This selection allows the installer to configure the maximum heating setpoint. The range is based on the adjustable deadband value Option 11, such that the minimum of the range is 50F/10C and the maximum is 90F/32C minus the deadband. Default is 88F/31C (based on the adjustable deadband default = 2). Option 28 — UV Light Reminder This selection allows the installer to select the number of months after which the UV Light icon will be displayed to indicate to the homeowner that it is time to call the dealer to have the UV Lights replaced. Selections available are OF (off), 6, 12, 18, 24, 30, 36, 42, 48. OF (off) — The UV Light reminder is turned off and will never be displayed. 6.48 — The number of months after which the UV Light reminder will be displayed, “CHECK UV LIGHT”. Default is OF (off). Option 30 — Programmable Fan (programmable models only) This selection allows the homeowner to program the fan selection to “Auto” or “On” fan operation for each of the program schedule periods. This selection is only available on programmable models. OF (off) — Programmable fan is disabled and the homeowner must manually select “Auto” or “On” for fan operation. On — Programmable fan is enabled. The homeowner can program “Auto” or “On” fan operation along with the heat and cool setpoints for each programmed period. When the program schedule is running, the programmed heat setpoint, cool setpoint, and fan selection for that period will be used. If the homeowner 34 “overrides” the programmed fan setting by pressing the fan button, the override selection will remain in effect until the next programmed period time. Default is OF (off). Option 31 — Daylight Savings Time Configuration (programmable models only) This selection allows the ...

Este manual também é adequado para os modelos :
Os termostatos - TP-NAC (1.19 mb)
Os termostatos - TP-NHP (1.19 mb)
Os termostatos - TP-PHP (1.19 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias