Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Honeywell, Modelo 44428

Fabricante : Honeywell
Arquivo Tamanho: 276.58 kb
Arquivo Nome : 44428.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


41213-6/95 Programmable Thermostat For Single Auto Temp II Heat Pump and Multistage Heat Pump Systems TM Hunter Fan Company • 2500 Frisco Avenue • Memphis, TN 38114 Table of Contents Congratulations! Features 2 Welcome to the Hunter energy saving family of quality Start Up 3 products. Keyboard Lock Feature 5 Your Hunter Programmable Thermostat allows you to find your maximum comfort level using the least amount of Setting The Time/Day Of The Week Personal Program Schedule 6 7 fuel. Through smart programming, this thermostat should Programming 8 pay for itself during its first season of use. Displaying Programs 11 Thank you for buying Hunter products! To Review The Current Temperature Setting 12 Manual Overrides 13 Using The Energy Monitor Usage Review 14 Temperature Span 15 Energy Usage Chart 16 Different Operation Modes 17 Trouble Shooting 18 Installing Thermostat 19 Remove Old Thermostat 20 Label Wires 20 Mount Wallplate and Thermostat 21 Connect Wires and Mount Thermostat Cover to Wall Plate 22 Features ¦ Manual Override For either temporary or constant temperature adjustments without program change. MO TU WE TH FR SA SU LOW BATT AM UNTIL NEXT PM PROG I8:88 88 PROG# 1 2 3 4 SET TEMP HOLD ROOM TEMP EMERG AUX HEAT COOL USAGE DELAY AUTO-RECOVERY n Easy-to-Read Digital Display Digital clock (liquid crystal display) indicates time of day AM or PM, day of week, current room temperature, current program number, LO BATT indicator, heat and cool indicator when heat or cool is on, and usage indicator. ¦ Manual Override and Compressor Safety Delay Compressor safety restart “Delay” appears on display. n Fingertip Programming n Low Battery Indicator Easy touch keyboard. Keys “LOW BATT” flashes when its time “beep” when pressed. to change the batteries. HOLD CLEAR HOLD CLEARor or HOLD CLEAR To set day: To set time: To set programs To review programs Press for Today and Yesterday Replace batteries when "Low Batt" indicator appears Next Prog To overide programmed temperatures (press for 3 seconds): To display energy usage: Temporary change until next program: Constant hold until manually cleared: Return to regular programmed temperature: MODEL: 44428 Auto Temp II Heat Pump RESET NORMALOFF A/C HEAT AUTO FAN HEAT RECOVERY EMERG. HEAT HOUR AUX USAGE PROG DAY MIN PROG DAY USAGE RETURN HOUR DAMIN HOUR MINPROG DA AUX USAGE PROG DA PROG PROG USAGE PROG PROG For Total Aux Usage Press ROOM TEMP AM MO 12:38 75 ¦ Key Hole for Keyboard Lock You can prevent tampering of programs by selecting keyboard lock feature. ¦ Key to lock keyboard. ¦ For raising temperature. ¦ For lowering temperature. ¦ Manual override hold clear button. ¦ Fan ON and AUTO Selector switch. ¦ Normal, Heat Recovery and Emergency Heat Switch ¦ Function Switch Switch for turning on heat and cooling systems. ¦ Vacation Override Provides permanent (vacation) temperature setting without program change. ¦ Convenient Programming Reference Simplified programming instructions are provided on inside of door cover for easy reference. n Exclusive Energy Monitor Measures and displays the amount of time the heating or air-conditioning system has operated today and yesterday. By programming your thermostat and monitoring the energy usage, you can save 9% to 30% on your fuel bills. Keyboard Quick Reference For entering hour of day. For resetting computer back to factory program and clock to 12:00 am. RESET Day selection key for selecting weekdays, weekends or individual day for programming. Energy Monitor key recalls energy usage today and yesterday. LCD shows energy usage in hours and minutes. Start Up Don’t Worry—Programming Is Easy! For entering minute of day. HOUR MIN DAY PROGPROG DAY AUX USAGE HOLD CLEAR Provides constant temperature setting by overriding stored programs, or converts to manual operation of thermostat. Also clears manual override to return to current program. USAGE Key to lower temperature setting For entering and reviewing programs. For entering current day of week. Displays cumulative usage of auxiliary heat in hours and minutes. Returns to current time This may seem to be a highly comprehensive and lengthy presentation of our product's features—don’t be intimidated. We have a lot to say because our product does have a lot of features. And we want to make sure you have complete information. You may find you'll want to use only a simple program…or all the features we have to offer. Just follow this manual one step at a time and you should quickly begin to feel comfortable with your new thermostat. RETURN and temperature. Key to raise temperature setting Besides, we’ve installed preset programs at 78° for air conditioning and 68° for heating. These programs are up and running immediately at installation. In case you don’t have time to enter your own programs right away. Start Up 4 Start Up 4 How To Save On Energy Costs You can generate significant savings with a programmable thermostat. The idea is to reduce usage when you don’t need it—when you’re not home...

Este manual também é adequado para os modelos :
Os termostatos - 44428 (276.58 kb)
Os termostatos - 44428 (276.58 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias