@name

These items have a check box ( ) for your installer to indicate which features are used in your system. As an EPA ENERGY STAR Partner, Home Automation, Inc. has determined that this thermostat meets the ENERGY STAR guidelines for energy efficiency. MAINTENANCE Your new thermostat is maintenance free. There is no battery to install or replace. If necessary, clean unit carefully with a mild soap solution on a soft cloth. 1 ABOUT HEAT PUMPS... A heat pump is a mechanical refrigeration system that o

Downloads : 2   Arquivo Tamanho: 1 mb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

With the STAGE TIMER (Option 10) set to 0, stages 2 and 3 will be controlled by the SPAN setting only. If the stage timer is set to 30, the system will turn on the next stage based on the SPAN setting or 30 minutes, which ever comes first. Span settings remain the same for Heating and Cooling. 44002-01 r051807 SYSTEM SETTINGS MENU The installer can set SYSTEM functions once the thermostat is installed. The default settings are shown in bold in the following list. Options are listed inside the pa

Downloads : 11   Arquivo Tamanho: 790 kb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

Locate, but do not disconnect the wires. (If wires are not visible, they may be connected to the back of the wall plate. Some models may have doors that open to expose the wires and mounting screws.) If your existing thermostat is marked... label the wire with this sticker: RH / r / vr / 4 RH 24 Volt RH W w / h heating W G g / f fan G * See page 27 for complete wiring diagram. uninstalling the existing unit, cont. 4. Using the provided stickers, label each wire according to the chart. (If the te

Downloads : 2   Arquivo Tamanho: 791 kb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

Set the switch to HG for a gas furnace or oil burner. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 5. Insert two fresh AA alkaline batteries. 6. Align the thermostat with the the wall plate, and snap the two halves together. 7. Restore power at the electrical panel or furnace. Thermometer System Switch Set Temperature Slider Fan Switch Battery Indicator Operation 1. Set the Set Temperature slider to the desired temperature. 2. The

Downloads : 0   Arquivo Tamanho: 714 kb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

4. Using the provided stickers, label each wire according to the chart. RC Y G W W (If the terminals are not labeled, contact a qualified HVAC technician.) note: Wire colors do not always comply with standards, so wire color should be ignored. refer to the existing terminal designation for proper identification. *If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect it to any terminal. This wire is used only for non-bat

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

Set & $aveSet & $aveSet & $ave Installation and Operation Manual Model 44360 Programmable Thermostat English Form# 42710-01 20091204 ©2009 Hunter Fan Co. Set & $aveSet & $aveSet & $ave Installation and Operation Manual Model 44360 Programmable Thermostat English 2 Table of Contents Important Information .............................................................................. 5 Tools ........................................................................................................ 6 U

Downloads : 1   Arquivo Tamanho: 1 mb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

(The ends of any extra wires should be wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. GRCRHYWJumper 18 DISABLE ENABLE RECOVERY HG HE G SYSTEM TYPE STD HP W/B Y/O RH RC Y1 FAN OPTION AMHEATTThermostat Cover System Switch G RC RH Y/O W/B Y1 DISABLE ENABLE RECOVERY HG HE G SYSTEM TYPE STD HP W/B Y/O RH RC Y1 FAN OPTION AMHEATTThermostat Cover System Switch G RC RH Y/O W/B Y1 inSTalling ThE ThErMoSTaT, C

Downloads : 2   Arquivo Tamanho: 456 kb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

CAUTION: The batteries are the only source of power used to operate your system. If you do not replace the batteries, the display will dim and your heating and cooling system will stop operation. NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving. Features (Model 42999) 69CTEMP SET TEMP FILTER LO BAT HOLD HEAT COOL ¦ Easy-To-Read Digital Display Liquid crystal display shows room temperature, se

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

See Figure 4. Ignore any wires which may be present, but which were not connected to the old thermostat. Terminal Screws Figure 4 • Be sure to tighten the terminal screws securely, as a loose wire could cause operational problems with your system or thermostat. • Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate. • Set the System Switch to “off”, and the Fan Switch to “auto”. • On the back of the thermostat are the System Set-Up Switches.

Downloads : 0   Arquivo Tamanho: 219 kb   Fabricante : Hunter Fan  
Categoria : Os termostatos
@name

3) After 15 seconds without a key press, the thermostat will r display mode. 4) When setting the program time, note the AM / PM indicator STEP 1: n Slide the System Switch to the HEAT or COOL position to program the corresponding system. NOTE: If the System Switch is in the OFF position, the last position used will be programmed. STEP 2: n Press to enter program mode. HEAT or COOL will be displayed on the LCD. STEP 3: n The Program hour and AM or PM indicator are flashing. Press to change the ho